{"id":{"repo_id":"manitoba","oai_identifier":"oai:mspace.lib.umanitoba.ca:1993/9150"},"canonical_url":"https://search.ndltd.org/etd/manitoba/oai:mspace.lib.umanitoba.ca:1993/9150","repository":{"repo_id":"manitoba","name":"University of Manitoba","base_url":"https://mspace.lib.umanitoba.ca/oai/request"},"display":{"title":"Evaluation of implement monitoring systems","abstract":"During monitoring of rear-mounted equipment, frequent rearward turning of tractor drivers in awkward postures can cause musculoskeletal disorders related to the back, neck, and shoulders. A camera-based monitoring system, consisting of one or more cameras placed on the implement and a monitor placed inside the tractor cab, has potential ergonomic benefits compared with traditional implement monitoring strategies by reducing the rearward turning and twisting movements of tractor drivers. A camera-based monitoring system was compared with two traditional monitoring strategies (direct looking and using rear-view mirrors) in a lab environment using a Tractor Air-Seeder Driving Simulator. The operator’s reaction time and response errors, head/neck movement (acceleration), and neck muscle temperature were compared for the three monitoring strategies. The camera-based monitoring system yielded significantly (α=0.05) better outcomes in terms of acceleration and muscle temperature values. No significant difference was observed for response errors.","abstract_html":"During monitoring of rear-mounted equipment, frequent rearward turning of tractor drivers in awkward postures can cause musculoskeletal disorders related to the back, neck, and shoulders. A camera-based monitoring system, consisting of one or more cameras placed on the implement and a monitor placed inside the tractor cab, has potential ergonomic benefits compared with traditional implement monitoring strategies by reducing the rearward turning and twisting movements of tractor drivers. A camera-based monitoring system was compared with two traditional monitoring strategies (direct looking and using rear-view mirrors) in a lab environment using a Tractor Air-Seeder Driving Simulator. The operator’s reaction time and response errors, head/neck movement (acceleration), and neck muscle temperature were compared for the three monitoring strategies. The camera-based monitoring system yielded significantly (α=0.05) better outcomes in terms of acceleration and muscle temperature values. No significant difference was observed for response errors.","abstract_has_math":false,"creators":["Rakhra, Aadesh"],"institution":null,"degree_name":null,"degree_level":"Master of Science (M.Sc.)","degree_discipline":"Biosystems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mann,Danny (Biosystems Engineering)"],"committee_chairs":[],"committee_members":["Paliwal, Jitendra (Biosystems Engineering)","Quanbury, Arthur (Medical Rehabilitation)"],"year":2012,"date_issued":"2012-09-25","date_published":"2012-09-25","updated_at":"2026-11-19T09:07:46Z","subjects":["Tractors","Farm implement monitoring","Agricultural ergonomics","Rear mounted implement","Accelerometers","Monitoring camera","Infrared thermal imaging","Musculoskeletal disorders","Evaluation implement monitoring"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1993/9150","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1993/9150","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amanitoba%3Aoai%3Amspace.lib.umanitoba.ca%3A1993%2F9150","prefix":"oai_dc"},"source_record":{"url":"https://mspace.lib.umanitoba.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amspace.lib.umanitoba.ca%3A1993%2F9150","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Paliwal, Jitendra (Biosystems Engineering)","Quanbury, Arthur (Medical Rehabilitation)"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Mann,Danny (Biosystems Engineering)"]},{"key":"dc:creator","label":"Author","values":["Rakhra, Aadesh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-09-25T23:04:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-09-25T23:04:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-09-25"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biosystems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master of Science (M.Sc.)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Tractors","Farm implement monitoring","Agricultural ergonomics","Rear mounted implement","Accelerometers","Monitoring camera","Infrared thermal imaging","Musculoskeletal disorders","Evaluation implement monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1993/9150"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["During monitoring of rear-mounted equipment, frequent rearward turning of tractor drivers in awkward postures can cause musculoskeletal disorders related to the back, neck, and shoulders. A camera-based monitoring system, consisting of one or more cameras placed on the implement and a monitor placed inside the tractor cab, has potential ergonomic benefits compared with traditional implement monitoring strategies by reducing the rearward turning and twisting movements of tractor drivers. A camera-based monitoring system was compared with two traditional monitoring strategies (direct looking and using rear-view mirrors) in a lab environment using a Tractor Air-Seeder Driving Simulator. The operator’s reaction time and response errors, head/neck movement (acceleration), and neck muscle temperature were compared for the three monitoring strategies. The camera-based monitoring system yielded significantly (α=0.05) better outcomes in terms of acceleration and muscle temperature values. No significant difference was observed for response errors."]},{"key":"dc:description.note","label":"Dc Description Note","values":["October 2012"]},{"key":"dc:title","label":"Title","values":["Evaluation of implement monitoring systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.committeemember":["Paliwal, Jitendra (Biosystems Engineering)","Quanbury, Arthur (Medical Rehabilitation)"],"dc:contributor.supervisor":["Mann,Danny (Biosystems Engineering)"],"dc:creator":["Rakhra, Aadesh"],"dc:date.accessioned":["2012-09-25T23:04:19Z"],"dc:date.available":["2012-09-25T23:04:19Z"],"dc:date.issued":["2012-09-25"],"dc:description.abstract":["During monitoring of rear-mounted equipment, frequent rearward turning of tractor drivers in awkward postures can cause musculoskeletal disorders related to the back, neck, and shoulders. A camera-based monitoring system, consisting of one or more cameras placed on the implement and a monitor placed inside the tractor cab, has potential ergonomic benefits compared with traditional implement monitoring strategies by reducing the rearward turning and twisting movements of tractor drivers. A camera-based monitoring system was compared with two traditional monitoring strategies (direct looking and using rear-view mirrors) in a lab environment using a Tractor Air-Seeder Driving Simulator. The operator’s reaction time and response errors, head/neck movement (acceleration), and neck muscle temperature were compared for the three monitoring strategies. The camera-based monitoring system yielded significantly (α=0.05) better outcomes in terms of acceleration and muscle temperature values. No significant difference was observed for response errors."],"dc:description.note":["October 2012"],"dc:identifier.uri":["http://hdl.handle.net/1993/9150"],"dc:language.iso":["eng"],"dc:subject":["Tractors","Farm implement monitoring","Agricultural ergonomics","Rear mounted implement","Accelerometers","Monitoring camera","Infrared thermal imaging","Musculoskeletal disorders","Evaluation implement monitoring"],"dc:title":["Evaluation of implement monitoring systems"],"dc:type":["master thesis"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biosystems Engineering"],"thesis:degree_level":["Master of Science (M.Sc.)"]},"updated_at":"2026-11-19T09:07:46Z"}