{"id":{"repo_id":"marshall","oai_identifier":"oai:mds.marshall.edu:etd-3077"},"canonical_url":"https://search.ndltd.org/etd/marshall/oai:mds.marshall.edu:etd-3077","repository":{"repo_id":"marshall","name":"Marshall University","base_url":"https://mds.marshall.edu/do/oai/"},"display":{"title":"Kinetics of proteolyic enzymes monitored online with mass spectrometry","abstract":"On-line reaction monitoring using electrospray ionization mass spectrometry was investigated with the goal of kinetically distinguishing the isomeric amino acids leucine and isoleucine. Leucine and isoleucine are isomers of identical mass (113.0946 Da) which are impossible to distinguish by their mass-to-charge ratios. These isomers are a source of ambiguity when sequencing peptides with exoproteases and mass spectrometry. Here we investigated the kinetics of on-line enzymatic reactions involving exoproteases for differentiating between leucine and isoleucine. The kinetics of the stepwise exopeptidase degradation of 12 leucine/isoleucine isomeric peptides was monitored in real-time with a Finnigan Mat LCQ with an electrospray ionization source. Data was analyzed within the Michaelis-Menten formalism via ion intensity-time curves and Lineweaver-Burke plots. A difference in the kinetic values for the two isomeric amino acids was expected due to the highly specific nature of enzymes. Based on the observed data leucine is hydrolyzed 2-3 times faster than isoleucine. The Michaelis constant, Km, was also larger for leucine than isoleucine by a factor of four.","abstract_html":"On-line reaction monitoring using electrospray ionization mass spectrometry was investigated with the goal of kinetically distinguishing the isomeric amino acids leucine and isoleucine. Leucine and isoleucine are isomers of identical mass (113.0946 Da) which are impossible to distinguish by their mass-to-charge ratios. These isomers are a source of ambiguity when sequencing peptides with exoproteases and mass spectrometry. Here we investigated the kinetics of on-line enzymatic reactions involving exoproteases for differentiating between leucine and isoleucine. The kinetics of the stepwise exopeptidase degradation of 12 leucine/isoleucine isomeric peptides was monitored in real-time with a Finnigan Mat LCQ with an electrospray ionization source. Data was analyzed within the Michaelis-Menten formalism via ion intensity-time curves and Lineweaver-Burke plots. A difference in the kinetic values for the two isomeric amino acids was expected due to the highly specific nature of enzymes. Based on the observed data leucine is hydrolyzed 2-3 times faster than isoleucine. The Michaelis constant, Km, was also larger for leucine than isoleucine by a factor of four.","abstract_has_math":false,"creators":["Rutherford, Jennifer L."],"institution":null,"degree_name":"Chemistry","degree_level":"Thesis","degree_discipline":"College of Science","degree_department":null,"school":null,"contributors":["William D. Price"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-21T19:58:30Z","subjects":["Chemistry","Computational Chemistry","Physical Chemistry","Physical Sciences and Mathematics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://mds.marshall.edu/etd/2072","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://mds.marshall.edu/etd/2072","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://mds.marshall.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Amds.marshall.edu%3Aetd-3077","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["William D. Price"]},{"key":"dc:creator","label":"Author","values":["Rutherford, Jennifer L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-13T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2001-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["College of Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Chemistry"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry","Computational Chemistry","Physical Chemistry","Physical Sciences and Mathematics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://mds.marshall.edu/etd/2072"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["On-line reaction monitoring using electrospray ionization mass spectrometry was investigated with the goal of kinetically distinguishing the isomeric amino acids leucine and isoleucine. Leucine and isoleucine are isomers of identical mass (113.0946 Da) which are impossible to distinguish by their mass-to-charge ratios. These isomers are a source of ambiguity when sequencing peptides with exoproteases and mass spectrometry. Here we investigated the kinetics of on-line enzymatic reactions involving exoproteases for differentiating between leucine and isoleucine. The kinetics of the stepwise exopeptidase degradation of 12 leucine/isoleucine isomeric peptides was monitored in real-time with a Finnigan Mat LCQ with an electrospray ionization source. Data was analyzed within the Michaelis-Menten formalism via ion intensity-time curves and Lineweaver-Burke plots. A difference in the kinetic values for the two isomeric amino acids was expected due to the highly specific nature of enzymes. Based on the observed data leucine is hydrolyzed 2-3 times faster than isoleucine. The Michaelis constant, Km, was also larger for leucine than isoleucine by a factor of four."]},{"key":"dc:title","label":"Title","values":["Kinetics of proteolyic enzymes monitored online with mass spectrometry"]}]}],"canonical_facts":{"dc:contributor":["William D. Price"],"dc:creator":["Rutherford, Jennifer L."],"dc:date.available":["2026-05-13T07:00:00Z"],"dc:date.created":["2001-01-01T08:00:00Z"],"dc:description.abstract":["On-line reaction monitoring using electrospray ionization mass spectrometry was investigated with the goal of kinetically distinguishing the isomeric amino acids leucine and isoleucine. Leucine and isoleucine are isomers of identical mass (113.0946 Da) which are impossible to distinguish by their mass-to-charge ratios. These isomers are a source of ambiguity when sequencing peptides with exoproteases and mass spectrometry. Here we investigated the kinetics of on-line enzymatic reactions involving exoproteases for differentiating between leucine and isoleucine. The kinetics of the stepwise exopeptidase degradation of 12 leucine/isoleucine isomeric peptides was monitored in real-time with a Finnigan Mat LCQ with an electrospray ionization source. Data was analyzed within the Michaelis-Menten formalism via ion intensity-time curves and Lineweaver-Burke plots. A difference in the kinetic values for the two isomeric amino acids was expected due to the highly specific nature of enzymes. Based on the observed data leucine is hydrolyzed 2-3 times faster than isoleucine. The Michaelis constant, Km, was also larger for leucine than isoleucine by a factor of four."],"dc:identifier":["https://mds.marshall.edu/etd/2072"],"dc:subject":["Chemistry","Computational Chemistry","Physical Chemistry","Physical Sciences and Mathematics"],"dc:title":["Kinetics of proteolyic enzymes monitored online with mass spectrometry"],"thesis:degree_discipline":["College of Science"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["Chemistry"]},"updated_at":"2026-11-21T19:58:30Z"}