{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/13003"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/13003","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Development of a Bio-Inspired Magnetostrictive Flow and Tactile Sensor","abstract":"A magnetostrictive sensor was designed, constructed, and evaluated for use as flow or tactile sensor. Vibrissa-like beams (whiskers) were cut from sheets of the magnetostrictive iron-gallium alloy, Galfenol. These beams were cantilevered, with the fixed end of the whisker attached to a permanent magnet to provide the whisker with a magnetic bias. The free portion of the whisker was quasi-statically loaded, causing the whisker-like sensor to bend. The bending-induced strain caused the magnetization of the whisker to change, resulting in a changing magnetic field in the area surrounding the whisker. The change in magnetic field was detected by a giant magnetoresistance (GMR) sensor placed in proximity to the whisker. Therefore, the electrical resistance change of the GMR sensor was a function of the bending in the whisker due to external forces. Prototype design was aided using a bidirectionally coupled magnetoelastic model for computer simulation. The prototype was tested and evaluated under tactile loading and low speed flow conditions.","abstract_html":"A magnetostrictive sensor was designed, constructed, and evaluated for use as flow or tactile sensor. Vibrissa-like beams (whiskers) were cut from sheets of the magnetostrictive iron-gallium alloy, Galfenol. These beams were cantilevered, with the fixed end of the whisker attached to a permanent magnet to provide the whisker with a magnetic bias. The free portion of the whisker was quasi-statically loaded, causing the whisker-like sensor to bend. The bending-induced strain caused the magnetization of the whisker to change, resulting in a changing magnetic field in the area surrounding the whisker. The change in magnetic field was detected by a giant magnetoresistance (GMR) sensor placed in proximity to the whisker. Therefore, the electrical resistance change of the GMR sensor was a function of the bending in the whisker due to external forces. Prototype design was aided using a bidirectionally coupled magnetoelastic model for computer simulation. The prototype was tested and evaluated under tactile loading and low speed flow conditions.","abstract_has_math":false,"creators":["Marana, Michael Adam"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Flatau, Alison"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T08:44:39Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/13003","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/13003","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F13003","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F13003","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Flatau, Alison"]},{"key":"dc:contributor.department","label":"Department","values":["Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Marana, Michael Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-10-10T11:17:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-10-10T11:17:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["BCMEM","Bio-Inspired","Galfenol","Magnetostrictive"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/13003"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A magnetostrictive sensor was designed, constructed, and evaluated for use as flow or tactile sensor. Vibrissa-like beams (whiskers) were cut from sheets of the magnetostrictive iron-gallium alloy, Galfenol. These beams were cantilevered, with the fixed end of the whisker attached to a permanent magnet to provide the whisker with a magnetic bias. The free portion of the whisker was quasi-statically loaded, causing the whisker-like sensor to bend. The bending-induced strain caused the magnetization of the whisker to change, resulting in a changing magnetic field in the area surrounding the whisker. The change in magnetic field was detected by a giant magnetoresistance (GMR) sensor placed in proximity to the whisker. Therefore, the electrical resistance change of the GMR sensor was a function of the bending in the whisker due to external forces. Prototype design was aided using a bidirectionally coupled magnetoelastic model for computer simulation. The prototype was tested and evaluated under tactile loading and low speed flow conditions."]},{"key":"dc:title","label":"Title","values":["Development of a Bio-Inspired Magnetostrictive Flow and Tactile Sensor"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Flatau, Alison"],"dc:contributor.department":["Aerospace Engineering"],"dc:creator":["Marana, Michael Adam"],"dc:date.accessioned":["2012-10-10T11:17:02Z"],"dc:date.available":["2012-10-10T11:17:02Z"],"dc:date.issued":["2012"],"dc:description.abstract":["A magnetostrictive sensor was designed, constructed, and evaluated for use as flow or tactile sensor. Vibrissa-like beams (whiskers) were cut from sheets of the magnetostrictive iron-gallium alloy, Galfenol. These beams were cantilevered, with the fixed end of the whisker attached to a permanent magnet to provide the whisker with a magnetic bias. The free portion of the whisker was quasi-statically loaded, causing the whisker-like sensor to bend. The bending-induced strain caused the magnetization of the whisker to change, resulting in a changing magnetic field in the area surrounding the whisker. The change in magnetic field was detected by a giant magnetoresistance (GMR) sensor placed in proximity to the whisker. Therefore, the electrical resistance change of the GMR sensor was a function of the bending in the whisker due to external forces. Prototype design was aided using a bidirectionally coupled magnetoelastic model for computer simulation. The prototype was tested and evaluated under tactile loading and low speed flow conditions."],"dc:identifier.uri":["http://hdl.handle.net/1903/13003"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["BCMEM","Bio-Inspired","Galfenol","Magnetostrictive"],"dc:subject.proquest":["Engineering"],"dc:title":["Development of a Bio-Inspired Magnetostrictive Flow and Tactile Sensor"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:44:39Z"}