{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/133"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/133","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Magnetic Anisotropy of Fe1-xGax Alloys","abstract":"Cubic magnetocrystalline anisotropy constants, K1 and K2, for Fe1-xGax alloys were measured using magnetization curves with x = 0.05, 0.125, 0.14, 0.18 and 0.20. Thin circular {110} disks with all <100>, <110> and <111> in the plane of the disk were used to measure K1 and K2. K1 was also measured with {100} circular disks. K1 for 5 at% Ga content has been found to be larger than that of pure Fe. K1 and K2 both drops gradually till 18 % Ga substitution. Then there is a sharp drop in the magnitude of both the constants. <110> and <111> directions were magnetically equivalent for all the compositions considered for this study resulting in K2 to be equal to 9K1/4. A calculation of anisotropy energy density verifies this result. Magnitude of K1 measured from both {110} and {100} disks were reasonably consistent.","abstract_html":"Cubic magnetocrystalline anisotropy constants, K1 and K2, for Fe1-xGax alloys were measured using magnetization curves with x = 0.05, 0.125, 0.14, 0.18 and 0.20. Thin circular {110} disks with all &lt;100&gt;, &lt;110&gt; and &lt;111&gt; in the plane of the disk were used to measure K1 and K2. K1 was also measured with {100} circular disks. K1 for 5 at% Ga content has been found to be larger than that of pure Fe. K1 and K2 both drops gradually till 18 % Ga substitution. Then there is a sharp drop in the magnitude of both the constants. &lt;110&gt; and &lt;111&gt; directions were magnetically equivalent for all the compositions considered for this study resulting in K2 to be equal to 9K1/4. A calculation of anisotropy energy density verifies this result. Magnitude of K1 measured from both {110} and {100} disks were reasonably consistent.","abstract_has_math":false,"creators":["Rafique, Sadia"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Material Science and Engineering","school":null,"contributors":[],"advisors":["Wuttig, Manfred","Salamanca-Riba, Lourdes","Cullen, James R"],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-12-22","date_published":"2003-12-22","updated_at":"2026-11-19T08:44:55Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/133","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/133","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F133","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F133","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wuttig, Manfred","Salamanca-Riba, Lourdes","Cullen, James R"]},{"key":"dc:contributor.department","label":"Department","values":["Material Science and Engineering"]},{"key":"dc:creator","label":"Author","values":["Rafique, Sadia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2004-05-31T19:54:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2004-05-31T19:54:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2003-12-22"]},{"key":"dc:relation","label":"Dc Relation","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Materials Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cubic magnetocrystalline anisotropy constants, K1 and K2, for Fe1-xGax alloys were measured using magnetization curves with x = 0.05, 0.125, 0.14, 0.18 and 0.20. Thin circular {110} disks with all <100>, <110> and <111> in the plane of the disk were used to measure K1 and K2. K1 was also measured with {100} circular disks. K1 for 5 at% Ga content has been found to be larger than that of pure Fe. K1 and K2 both drops gradually till 18 % Ga substitution. Then there is a sharp drop in the magnitude of both the constants. <110> and <111> directions were magnetically equivalent for all the compositions considered for this study resulting in K2 to be equal to 9K1/4. A calculation of anisotropy energy density verifies this result. Magnitude of K1 measured from both {110} and {100} disks were reasonably consistent."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2385225 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Magnetic Anisotropy of Fe1-xGax Alloys"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wuttig, Manfred","Salamanca-Riba, Lourdes","Cullen, James R"],"dc:contributor.department":["Material Science and Engineering"],"dc:creator":["Rafique, Sadia"],"dc:date.accessioned":["2004-05-31T19:54:12Z"],"dc:date.available":["2004-05-31T19:54:12Z"],"dc:date.issued":["2003-12-22"],"dc:description.abstract":["Cubic magnetocrystalline anisotropy constants, K1 and K2, for Fe1-xGax alloys were measured using magnetization curves with x = 0.05, 0.125, 0.14, 0.18 and 0.20. Thin circular {110} disks with all <100>, <110> and <111> in the plane of the disk were used to measure K1 and K2. K1 was also measured with {100} circular disks. K1 for 5 at% Ga content has been found to be larger than that of pure Fe. K1 and K2 both drops gradually till 18 % Ga substitution. Then there is a sharp drop in the magnitude of both the constants. <110> and <111> directions were magnetically equivalent for all the compositions considered for this study resulting in K2 to be equal to 9K1/4. A calculation of anisotropy energy density verifies this result. Magnitude of K1 measured from both {110} and {100} disks were reasonably consistent."],"dc:format.extent":["2385225 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/133"],"dc:language.iso":["en_US"],"dc:relation":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Engineering, Materials Science"],"dc:title":["Magnetic Anisotropy of Fe1-xGax Alloys"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:44:55Z"}