{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/13558"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/13558","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Application of Plate Heat Exchanger for Low Temperature Lift Heat Pump Systems","abstract":"In this thesis I investigated the energy saving potential of a low temperature lift heat pump (LTLHP) such as water source heat pump (WSHP), and studied the utilization of a plate heat exchanger (PHE) as the LTLHP evaporator. Due to the facility limitation, I only tested and studied the evaporator for LTLHP. Since the LTLHP requires a large water flow rate, its heat source liquid-to-refrigerant PHE is operated at lower refrigerant mass flux than typical applications. I varied the vapor quality, heat flux, evaporation pressure, and refrigerant mass flux to provide unique heat transfer characteristics, and I studied their effects on evaporation heat transfer. Based on the collected data, I concluded that at a low mass flux range, evaporation heat transfer is dominated by nucleate boiling, and convective boiling has mall influence. In addition, I carried out a simulation to compare the performance of WSHP with air source heat pump (ASHP).","abstract_html":"In this thesis I investigated the energy saving potential of a low temperature lift heat pump (LTLHP) such as water source heat pump (WSHP), and studied the utilization of a plate heat exchanger (PHE) as the LTLHP evaporator. Due to the facility limitation, I only tested and studied the evaporator for LTLHP. Since the LTLHP requires a large water flow rate, its heat source liquid-to-refrigerant PHE is operated at lower refrigerant mass flux than typical applications. I varied the vapor quality, heat flux, evaporation pressure, and refrigerant mass flux to provide unique heat transfer characteristics, and I studied their effects on evaporation heat transfer. Based on the collected data, I concluded that at a low mass flux range, evaporation heat transfer is dominated by nucleate boiling, and convective boiling has mall influence. In addition, I carried out a simulation to compare the performance of WSHP with air source heat pump (ASHP).","abstract_has_math":false,"creators":["Li, Song"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Radermacher, Reinhard"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T08:53:28Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/13558","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/13558","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F13558","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F13558","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Radermacher, Reinhard"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Li, Song"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-06T07:17:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-06T07:17:39Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/13558"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis I investigated the energy saving potential of a low temperature lift heat pump (LTLHP) such as water source heat pump (WSHP), and studied the utilization of a plate heat exchanger (PHE) as the LTLHP evaporator. Due to the facility limitation, I only tested and studied the evaporator for LTLHP. Since the LTLHP requires a large water flow rate, its heat source liquid-to-refrigerant PHE is operated at lower refrigerant mass flux than typical applications. I varied the vapor quality, heat flux, evaporation pressure, and refrigerant mass flux to provide unique heat transfer characteristics, and I studied their effects on evaporation heat transfer. Based on the collected data, I concluded that at a low mass flux range, evaporation heat transfer is dominated by nucleate boiling, and convective boiling has mall influence. In addition, I carried out a simulation to compare the performance of WSHP with air source heat pump (ASHP)."]},{"key":"dc:title","label":"Title","values":["Application of Plate Heat Exchanger for Low Temperature Lift Heat Pump Systems"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Radermacher, Reinhard"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Li, Song"],"dc:date.accessioned":["2013-02-06T07:17:39Z"],"dc:date.available":["2013-02-06T07:17:39Z"],"dc:date.issued":["2012"],"dc:description.abstract":["In this thesis I investigated the energy saving potential of a low temperature lift heat pump (LTLHP) such as water source heat pump (WSHP), and studied the utilization of a plate heat exchanger (PHE) as the LTLHP evaporator. Due to the facility limitation, I only tested and studied the evaporator for LTLHP. Since the LTLHP requires a large water flow rate, its heat source liquid-to-refrigerant PHE is operated at lower refrigerant mass flux than typical applications. I varied the vapor quality, heat flux, evaporation pressure, and refrigerant mass flux to provide unique heat transfer characteristics, and I studied their effects on evaporation heat transfer. Based on the collected data, I concluded that at a low mass flux range, evaporation heat transfer is dominated by nucleate boiling, and convective boiling has mall influence. In addition, I carried out a simulation to compare the performance of WSHP with air source heat pump (ASHP)."],"dc:identifier.uri":["http://hdl.handle.net/1903/13558"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Engineering"],"dc:title":["Application of Plate Heat Exchanger for Low Temperature Lift Heat Pump Systems"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:53:28Z"}