{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/13653"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/13653","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Experimental and Computational Analysis of the Fire Suppression Effectiveness of Halon 1301 Replacements","abstract":"Experimental and computational work was performed to help understand why sub-inerting concentrations of HFC-125 (C2HF5) produced overpressures in the FAA aerosol can explosion test. The fire suppression performance of HCFC-123 (C2HCl2F3) was also investigated to determine whether it may perform better than HFC-125. Thermodynamic analysis shows that both agents increase the overall heat release for lean mixtures containing the aerosol can contents. HFC-125 also increases the overall reaction rate when added to lean mixtures. The overall reaction rate of mixtures containing HCFC-123 is generally lowered when sub-inerting concentrations are added. Experimental results showed that HCFC-123 has a lower minimum inerting concentration (8.9%) than HFC-125 (13.5%). Mixtures containing HCFC-123 were found to produce peak pressures in the 2 L chamber that were estimated to cause overpressures in the FAA chamber. Nitrogen dilution resulting in 20% oxygen in air was successful at eliminating the overpressure of mixtures containing HCFC-123.","abstract_html":"Experimental and computational work was performed to help understand why sub-inerting concentrations of HFC-125 (C2HF5) produced overpressures in the FAA aerosol can explosion test. The fire suppression performance of HCFC-123 (C2HCl2F3) was also investigated to determine whether it may perform better than HFC-125. Thermodynamic analysis shows that both agents increase the overall heat release for lean mixtures containing the aerosol can contents. HFC-125 also increases the overall reaction rate when added to lean mixtures. The overall reaction rate of mixtures containing HCFC-123 is generally lowered when sub-inerting concentrations are added. Experimental results showed that HCFC-123 has a lower minimum inerting concentration (8.9%) than HFC-125 (13.5%). Mixtures containing HCFC-123 were found to produce peak pressures in the 2 L chamber that were estimated to cause overpressures in the FAA chamber. Nitrogen dilution resulting in 20% oxygen in air was successful at eliminating the overpressure of mixtures containing HCFC-123.","abstract_has_math":false,"creators":["Pagliaro, John Leonard"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Sunderland, Peter B"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T08:51:25Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1903/13653","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/1903/13653","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F13653","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sunderland, Peter B"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Pagliaro, John Leonard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-07T07:20:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-07T07:20:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Aircraft Cargo Bay","FAA Aerosol Can Test","Fire Suppression","Halon 1301","HCFC-123","HFC-125"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Mechanical engineering","Chemical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/13653"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experimental and computational work was performed to help understand why sub-inerting concentrations of HFC-125 (C2HF5) produced overpressures in the FAA aerosol can explosion test. The fire suppression performance of HCFC-123 (C2HCl2F3) was also investigated to determine whether it may perform better than HFC-125. Thermodynamic analysis shows that both agents increase the overall heat release for lean mixtures containing the aerosol can contents. HFC-125 also increases the overall reaction rate when added to lean mixtures. The overall reaction rate of mixtures containing HCFC-123 is generally lowered when sub-inerting concentrations are added. Experimental results showed that HCFC-123 has a lower minimum inerting concentration (8.9%) than HFC-125 (13.5%). Mixtures containing HCFC-123 were found to produce peak pressures in the 2 L chamber that were estimated to cause overpressures in the FAA chamber. Nitrogen dilution resulting in 20% oxygen in air was successful at eliminating the overpressure of mixtures containing HCFC-123."]},{"key":"dc:title","label":"Title","values":["Experimental and Computational Analysis of the Fire Suppression Effectiveness of Halon 1301 Replacements"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sunderland, Peter B"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Pagliaro, John Leonard"],"dc:date.accessioned":["2013-02-07T07:20:58Z"],"dc:date.available":["2013-02-07T07:20:58Z"],"dc:date.issued":["2012"],"dc:description.abstract":["Experimental and computational work was performed to help understand why sub-inerting concentrations of HFC-125 (C2HF5) produced overpressures in the FAA aerosol can explosion test. The fire suppression performance of HCFC-123 (C2HCl2F3) was also investigated to determine whether it may perform better than HFC-125. Thermodynamic analysis shows that both agents increase the overall heat release for lean mixtures containing the aerosol can contents. HFC-125 also increases the overall reaction rate when added to lean mixtures. The overall reaction rate of mixtures containing HCFC-123 is generally lowered when sub-inerting concentrations are added. Experimental results showed that HCFC-123 has a lower minimum inerting concentration (8.9%) than HFC-125 (13.5%). Mixtures containing HCFC-123 were found to produce peak pressures in the 2 L chamber that were estimated to cause overpressures in the FAA chamber. Nitrogen dilution resulting in 20% oxygen in air was successful at eliminating the overpressure of mixtures containing HCFC-123."],"dc:identifier.uri":["http://hdl.handle.net/1903/13653"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["Aircraft Cargo Bay","FAA Aerosol Can Test","Fire Suppression","Halon 1301","HCFC-123","HFC-125"],"dc:subject.proquest":["Mechanical engineering","Chemical engineering"],"dc:title":["Experimental and Computational Analysis of the Fire Suppression Effectiveness of Halon 1301 Replacements"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:51:25Z"}