{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/1453"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/1453","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Analysis of Fire Conditions in a Closed-End Tunnel","abstract":"Many studies have addressed fires in tunnels. For the most part, these previous studies have addressed fires that might occur during operation of the tunnel, when the tunnel has openings at both ends. During construction of a tunnel, the tunnel has only one opening as the tunnel is being bored. Analysis of fire conditions that might develop during construction of a tunnel is addressed here. A number of analyses are presented to assess tenability conditions in a closed-end subsurface environment as a result of different postulated fire scenarios. The purpose of these analyses is to develop fire tenability criteria for use in evaluating subsurface life and fire safety.","abstract_html":"Many studies have addressed fires in tunnels. For the most part, these previous studies have addressed fires that might occur during operation of the tunnel, when the tunnel has openings at both ends. During construction of a tunnel, the tunnel has only one opening as the tunnel is being bored. Analysis of fire conditions that might develop during construction of a tunnel is addressed here. A number of analyses are presented to assess tenability conditions in a closed-end subsurface environment as a result of different postulated fire scenarios. The purpose of these analyses is to develop fire tenability criteria for use in evaluating subsurface life and fire safety.","abstract_has_math":false,"creators":["DeJoseph, Joelle"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Mowrer, Frederick W"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-05-18","date_published":"2004-05-18","updated_at":"2026-11-19T08:53:49Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/1453","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/1453","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F1453","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F1453","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mowrer, Frederick W"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["DeJoseph, Joelle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2004-06-04T05:43:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2004-06-04T05:43:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-05-18"]},{"key":"dc:relation","label":"Dc Relation","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["tunnel","closed-end","tenability","Froude Number","Richardson Number"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/1453"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Many studies have addressed fires in tunnels. For the most part, these previous studies have addressed fires that might occur during operation of the tunnel, when the tunnel has openings at both ends. During construction of a tunnel, the tunnel has only one opening as the tunnel is being bored. Analysis of fire conditions that might develop during construction of a tunnel is addressed here. A number of analyses are presented to assess tenability conditions in a closed-end subsurface environment as a result of different postulated fire scenarios. The purpose of these analyses is to develop fire tenability criteria for use in evaluating subsurface life and fire safety."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["875865 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analysis of Fire Conditions in a Closed-End Tunnel"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mowrer, Frederick W"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["DeJoseph, Joelle"],"dc:date.accessioned":["2004-06-04T05:43:22Z"],"dc:date.available":["2004-06-04T05:43:22Z"],"dc:date.issued":["2004-05-18"],"dc:description.abstract":["Many studies have addressed fires in tunnels. For the most part, these previous studies have addressed fires that might occur during operation of the tunnel, when the tunnel has openings at both ends. During construction of a tunnel, the tunnel has only one opening as the tunnel is being bored. Analysis of fire conditions that might develop during construction of a tunnel is addressed here. A number of analyses are presented to assess tenability conditions in a closed-end subsurface environment as a result of different postulated fire scenarios. The purpose of these analyses is to develop fire tenability criteria for use in evaluating subsurface life and fire safety."],"dc:format.extent":["875865 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/1453"],"dc:language.iso":["en_US"],"dc:relation":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["tunnel","closed-end","tenability","Froude Number","Richardson Number"],"dc:subject.proquest":["Engineering, General"],"dc:title":["Analysis of Fire Conditions in a Closed-End Tunnel"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:53:49Z"}