{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/16110"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/16110","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Leveraging Porous Silicon Carbide to Create Simultaneously Low Stiffness and High Frequency AFM Microcantilevers","abstract":"Many operative modes of the atomic force microscope (AFM) are optimized by using cantilever probes that have both a low force constant and a high resonance frequency. Due to fabrication limitations, however, this ideal cannot be achieved without resorting to sizes incompatible with standard AFM instrumentation. This project proposes that cantilevers made from electrochemically etched porous silicon carbide (SiC) enjoy reduced force constants without significantly sacrificing frequency or size. The study includes prototype fabrication, as well as parametric experiments on the etching recipe and suggestions to improve the process. Analysis of the mechanical properties of the prototypes proves that introducing porosity to the structure greatly reduces the force constant (porous k = 0.27 bulk k) while only slightly reducing the resonance frequency (porous f0 = 0.86 bulk f0).","abstract_html":"Many operative modes of the atomic force microscope (AFM) are optimized by using cantilever probes that have both a low force constant and a high resonance frequency. Due to fabrication limitations, however, this ideal cannot be achieved without resorting to sizes incompatible with standard AFM instrumentation. This project proposes that cantilevers made from electrochemically etched porous silicon carbide (SiC) enjoy reduced force constants without significantly sacrificing frequency or size. The study includes prototype fabrication, as well as parametric experiments on the etching recipe and suggestions to improve the process. Analysis of the mechanical properties of the prototypes proves that introducing porosity to the structure greatly reduces the force constant (porous k = 0.27 bulk k) while only slightly reducing the resonance frequency (porous f0 = 0.86 bulk f0).","abstract_has_math":false,"creators":["Barkley, Sarice"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Solares, Santiago"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-19T08:49:37Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/16110"],"render_values":[{"text":"http://hdl.handle.net/1903/16110","href":"https://hdl.handle.net/1903/16110","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/M2JC8F","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/M2JC8F","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F16110","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F16110","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Solares, Santiago"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Barkley, Sarice"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-02-05T06:40:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-02-05T06:40:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["AFM","cantilever","HF","porous","probe","SiC"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Mechanical engineering","Nanotechnology","Nanoscience"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/M2JC8F"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/16110"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Many operative modes of the atomic force microscope (AFM) are optimized by using cantilever probes that have both a low force constant and a high resonance frequency. Due to fabrication limitations, however, this ideal cannot be achieved without resorting to sizes incompatible with standard AFM instrumentation. This project proposes that cantilevers made from electrochemically etched porous silicon carbide (SiC) enjoy reduced force constants without significantly sacrificing frequency or size. The study includes prototype fabrication, as well as parametric experiments on the etching recipe and suggestions to improve the process. Analysis of the mechanical properties of the prototypes proves that introducing porosity to the structure greatly reduces the force constant (porous k = 0.27 bulk k) while only slightly reducing the resonance frequency (porous f0 = 0.86 bulk f0)."]},{"key":"dc:title","label":"Title","values":["Leveraging Porous Silicon Carbide to Create Simultaneously Low Stiffness and High Frequency AFM Microcantilevers"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Solares, Santiago"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Barkley, Sarice"],"dc:date.accessioned":["2015-02-05T06:40:57Z"],"dc:date.available":["2015-02-05T06:40:57Z"],"dc:date.issued":["2014"],"dc:description.abstract":["Many operative modes of the atomic force microscope (AFM) are optimized by using cantilever probes that have both a low force constant and a high resonance frequency. Due to fabrication limitations, however, this ideal cannot be achieved without resorting to sizes incompatible with standard AFM instrumentation. This project proposes that cantilevers made from electrochemically etched porous silicon carbide (SiC) enjoy reduced force constants without significantly sacrificing frequency or size. The study includes prototype fabrication, as well as parametric experiments on the etching recipe and suggestions to improve the process. Analysis of the mechanical properties of the prototypes proves that introducing porosity to the structure greatly reduces the force constant (porous k = 0.27 bulk k) while only slightly reducing the resonance frequency (porous f0 = 0.86 bulk f0)."],"dc:identifier":["https://doi.org/10.13016/M2JC8F"],"dc:identifier.uri":["http://hdl.handle.net/1903/16110"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["AFM","cantilever","HF","porous","probe","SiC"],"dc:subject.proquest":["Mechanical engineering","Nanotechnology","Nanoscience"],"dc:title":["Leveraging Porous Silicon Carbide to Create Simultaneously Low Stiffness and High Frequency AFM Microcantilevers"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:49:37Z"}