{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/1709"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/1709","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Predicting Smoke Detector Responce Using a Quantitative Salt-Water Modeling Technique","abstract":"This investigation provides a detailed analysis of the hydraulic analogue technique used as a predictive tool for understanding smoke detector response within a complex enclosure. There currently exists no collectively accepted method for predicting the response of smoke detectors; one of the most important elements in life safety. A quantitative technique has been developed using salt-water modeling and planar laser induced fluorescence (PLIF) diagnostics. The non-intrusive diagnostic technique is used to temporally and spatially characterize the dispersion of a buoyant plume within a 1/7th scale room-corridor-room enclosure. This configuration is geometrically similar to a full-scale fire test facility, where local conditions were characterized near five ionization type smoke detectors placed throughout the enclosure. An evaluation of the scaled local conditions and dispersive event times for both systems was used to formulate a preliminary predictive detector response model for use with the hydraulic analogue.","abstract_html":"This investigation provides a detailed analysis of the hydraulic analogue technique used as a predictive tool for understanding smoke detector response within a complex enclosure. There currently exists no collectively accepted method for predicting the response of smoke detectors; one of the most important elements in life safety. A quantitative technique has been developed using salt-water modeling and planar laser induced fluorescence (PLIF) diagnostics. The non-intrusive diagnostic technique is used to temporally and spatially characterize the dispersion of a buoyant plume within a 1/7th scale room-corridor-room enclosure. This configuration is geometrically similar to a full-scale fire test facility, where local conditions were characterized near five ionization type smoke detectors placed throughout the enclosure. An evaluation of the scaled local conditions and dispersive event times for both systems was used to formulate a preliminary predictive detector response model for use with the hydraulic analogue.","abstract_has_math":false,"creators":["jankiewicz, sean"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Marshall, Andre","Roby, Richard"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-06-16","date_published":"2004-06-16","updated_at":"2026-11-19T08:50:20Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/1709","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/1709","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F1709","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F1709","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marshall, Andre","Roby, Richard"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["jankiewicz, sean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2004-08-27T05:17:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2004-08-27T05:17:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2004-06-16"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["fire","salt water","PLIF","modeling","smoke detector","dispersion"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/1709"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This investigation provides a detailed analysis of the hydraulic analogue technique used as a predictive tool for understanding smoke detector response within a complex enclosure. There currently exists no collectively accepted method for predicting the response of smoke detectors; one of the most important elements in life safety. A quantitative technique has been developed using salt-water modeling and planar laser induced fluorescence (PLIF) diagnostics. The non-intrusive diagnostic technique is used to temporally and spatially characterize the dispersion of a buoyant plume within a 1/7th scale room-corridor-room enclosure. This configuration is geometrically similar to a full-scale fire test facility, where local conditions were characterized near five ionization type smoke detectors placed throughout the enclosure. An evaluation of the scaled local conditions and dispersive event times for both systems was used to formulate a preliminary predictive detector response model for use with the hydraulic analogue."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["5005392 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Predicting Smoke Detector Responce Using a Quantitative Salt-Water Modeling Technique"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marshall, Andre","Roby, Richard"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["jankiewicz, sean"],"dc:date.accessioned":["2004-08-27T05:17:58Z"],"dc:date.available":["2004-08-27T05:17:58Z"],"dc:date.issued":["2004-06-16"],"dc:description.abstract":["This investigation provides a detailed analysis of the hydraulic analogue technique used as a predictive tool for understanding smoke detector response within a complex enclosure. There currently exists no collectively accepted method for predicting the response of smoke detectors; one of the most important elements in life safety. A quantitative technique has been developed using salt-water modeling and planar laser induced fluorescence (PLIF) diagnostics. The non-intrusive diagnostic technique is used to temporally and spatially characterize the dispersion of a buoyant plume within a 1/7th scale room-corridor-room enclosure. This configuration is geometrically similar to a full-scale fire test facility, where local conditions were characterized near five ionization type smoke detectors placed throughout the enclosure. An evaluation of the scaled local conditions and dispersive event times for both systems was used to formulate a preliminary predictive detector response model for use with the hydraulic analogue."],"dc:format.extent":["5005392 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/1709"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["fire","salt water","PLIF","modeling","smoke detector","dispersion"],"dc:subject.proquest":["Engineering, General"],"dc:title":["Predicting Smoke Detector Responce Using a Quantitative Salt-Water Modeling Technique"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:20Z"}