{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/18447"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/18447","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Variable Recruitment in Bundles of Miniature Pneumatic Artificial Muscles and Space Qualified Pneumatic Artificial Muscles","abstract":"The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these manipulators experience efficiency losses when operated outside their target performance ranges. The unidirectional actuation behavior of a miniature PAM bundle and bidirectional actuation behavior of an antagonistic pair of miniature PAM bundles are characterized and modeled. The results are used to motivate the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle to improve the operating efficiency of the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed.","abstract_html":"The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these manipulators experience efficiency losses when operated outside their target performance ranges. The unidirectional actuation behavior of a miniature PAM bundle and bidirectional actuation behavior of an antagonistic pair of miniature PAM bundles are characterized and modeled. The results are used to motivate the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle to improve the operating efficiency of the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed.","abstract_has_math":false,"creators":["DeLaHunt, Sylvie Adams"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Wereley, Norman M"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T08:48:59Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/18447"],"render_values":[{"text":"http://hdl.handle.net/1903/18447","href":"https://hdl.handle.net/1903/18447","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/M2X78G","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/M2X78G","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F18447","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F18447","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wereley, Norman M"]},{"key":"dc:contributor.department","label":"Department","values":["Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["DeLaHunt, Sylvie Adams"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-06-22T06:24:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-06-22T06:24:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["McKibben Artificial Muscle","Miniature Pneumatic Artificial Muscle","Pneumatic Artificial Muscle","Space Robotics","Variable Recruitment"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Aerospace engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/M2X78G"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/18447"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these manipulators experience efficiency losses when operated outside their target performance ranges. The unidirectional actuation behavior of a miniature PAM bundle and bidirectional actuation behavior of an antagonistic pair of miniature PAM bundles are characterized and modeled. The results are used to motivate the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle to improve the operating efficiency of the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed."]},{"key":"dc:title","label":"Title","values":["Variable Recruitment in Bundles of Miniature Pneumatic Artificial Muscles and Space Qualified Pneumatic Artificial Muscles"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wereley, Norman M"],"dc:contributor.department":["Aerospace Engineering"],"dc:creator":["DeLaHunt, Sylvie Adams"],"dc:date.accessioned":["2016-06-22T06:24:24Z"],"dc:date.available":["2016-06-22T06:24:24Z"],"dc:date.issued":["2016"],"dc:description.abstract":["The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these manipulators experience efficiency losses when operated outside their target performance ranges. The unidirectional actuation behavior of a miniature PAM bundle and bidirectional actuation behavior of an antagonistic pair of miniature PAM bundles are characterized and modeled. The results are used to motivate the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle to improve the operating efficiency of the actuator. Additionally, the fabrication and quasi-static testing results for PAMs assembled from candidate space qualified bladder and braided sleeve materials for use in space robotics are assessed."],"dc:identifier":["https://doi.org/10.13016/M2X78G"],"dc:identifier.uri":["http://hdl.handle.net/1903/18447"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["McKibben Artificial Muscle","Miniature Pneumatic Artificial Muscle","Pneumatic Artificial Muscle","Space Robotics","Variable Recruitment"],"dc:subject.proquest":["Aerospace engineering"],"dc:title":["Variable Recruitment in Bundles of Miniature Pneumatic Artificial Muscles and Space Qualified Pneumatic Artificial Muscles"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:48:59Z"}