{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/19097"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/19097","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"SUBJECT-SPECIFIC MULTICHANNEL BLIND SYSTEM IDENTIFICATION OF HUMAN ARTERIAL TREE VIA CUFF OSCILLATION MEASUREMENTS","abstract":"We developed and evaluated a mathematical model-based method to monitor cardiovascular health and estimate risk predictors from two peripheral cuff oscillation measurements. The model structure was established by studying tube-load models individually augmented with a gain, Voigt model, and standard linear solid model to best capture the relationship between carotid tonometry and cuff waveforms at the upper arm and ankle. The arm-cuff interface was better modeled with increasing viscoelasticity but not as much for the ankle-cuff interface. Next, model-estimated ankle blood pressure waveforms were used to formulate a matrix equation for estimating wave reflection. Subsequently derived risk predictors were adequately correlated with those from reference methods. Finally, subject-specific central blood pressure waveforms were estimated from two cuff oscillation signals via multichannel blind system identification. The model estimated central arterial blood pressure waveforms with good accuracy with a median RMSE of 3.08 mmHg and IQR of 1.71 mmHg.","abstract_html":"We developed and evaluated a mathematical model-based method to monitor cardiovascular health and estimate risk predictors from two peripheral cuff oscillation measurements. The model structure was established by studying tube-load models individually augmented with a gain, Voigt model, and standard linear solid model to best capture the relationship between carotid tonometry and cuff waveforms at the upper arm and ankle. The arm-cuff interface was better modeled with increasing viscoelasticity but not as much for the ankle-cuff interface. Next, model-estimated ankle blood pressure waveforms were used to formulate a matrix equation for estimating wave reflection. Subsequently derived risk predictors were adequately correlated with those from reference methods. Finally, subject-specific central blood pressure waveforms were estimated from two cuff oscillation signals via multichannel blind system identification. The model estimated central arterial blood pressure waveforms with good accuracy with a median RMSE of 3.08 mmHg and IQR of 1.71 mmHg.","abstract_has_math":false,"creators":["Lee, Jongchan"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Hahn, Jin-Oh"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T08:50:15Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/19097"],"render_values":[{"text":"http://hdl.handle.net/1903/19097","href":"https://hdl.handle.net/1903/19097","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/M26J9F","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/M26J9F","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F19097","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F19097","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hahn, Jin-Oh"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lee, Jongchan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-25T06:40:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-25T06:40:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["arterial blood pressure","arterial tree","mathematical modeling","pulse volume waveform","transfer function","viscoelastic model"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Biomedical engineering","Mechanical engineering","Biomechanics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/M26J9F"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/19097"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["We developed and evaluated a mathematical model-based method to monitor cardiovascular health and estimate risk predictors from two peripheral cuff oscillation measurements. The model structure was established by studying tube-load models individually augmented with a gain, Voigt model, and standard linear solid model to best capture the relationship between carotid tonometry and cuff waveforms at the upper arm and ankle. The arm-cuff interface was better modeled with increasing viscoelasticity but not as much for the ankle-cuff interface. Next, model-estimated ankle blood pressure waveforms were used to formulate a matrix equation for estimating wave reflection. Subsequently derived risk predictors were adequately correlated with those from reference methods. Finally, subject-specific central blood pressure waveforms were estimated from two cuff oscillation signals via multichannel blind system identification. The model estimated central arterial blood pressure waveforms with good accuracy with a median RMSE of 3.08 mmHg and IQR of 1.71 mmHg."]},{"key":"dc:title","label":"Title","values":["SUBJECT-SPECIFIC MULTICHANNEL BLIND SYSTEM IDENTIFICATION OF HUMAN ARTERIAL TREE VIA CUFF OSCILLATION MEASUREMENTS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hahn, Jin-Oh"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Lee, Jongchan"],"dc:date.accessioned":["2017-01-25T06:40:49Z"],"dc:date.available":["2017-01-25T06:40:49Z"],"dc:date.issued":["2016"],"dc:description.abstract":["We developed and evaluated a mathematical model-based method to monitor cardiovascular health and estimate risk predictors from two peripheral cuff oscillation measurements. The model structure was established by studying tube-load models individually augmented with a gain, Voigt model, and standard linear solid model to best capture the relationship between carotid tonometry and cuff waveforms at the upper arm and ankle. The arm-cuff interface was better modeled with increasing viscoelasticity but not as much for the ankle-cuff interface. Next, model-estimated ankle blood pressure waveforms were used to formulate a matrix equation for estimating wave reflection. Subsequently derived risk predictors were adequately correlated with those from reference methods. Finally, subject-specific central blood pressure waveforms were estimated from two cuff oscillation signals via multichannel blind system identification. The model estimated central arterial blood pressure waveforms with good accuracy with a median RMSE of 3.08 mmHg and IQR of 1.71 mmHg."],"dc:identifier":["https://doi.org/10.13016/M26J9F"],"dc:identifier.uri":["http://hdl.handle.net/1903/19097"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["arterial blood pressure","arterial tree","mathematical modeling","pulse volume waveform","transfer function","viscoelastic model"],"dc:subject.proquest":["Biomedical engineering","Mechanical engineering","Biomechanics"],"dc:title":["SUBJECT-SPECIFIC MULTICHANNEL BLIND SYSTEM IDENTIFICATION OF HUMAN ARTERIAL TREE VIA CUFF OSCILLATION MEASUREMENTS"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:15Z"}