{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/19098"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/19098","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Water Mist Suppression in a Turbulent Line Burner","abstract":"An experimental study of water mist fire suppression in a buoyant, turbulent diffusion flame is presented. An existing turbulent line burner facility was modified to allow for water mist suppression. These modifications include streamlining the oxidizer delivery system, facility improvements to increase mist generation efficiency, as well as the addition of a mist containment system and an enhanced exhaust flow to homogenize the water mist in the flame region and reduce secondary flows. Following these improvements, the capabilities of the water mist generation system were characterized both using a classical mass balance approach and using more modern advanced diagnostic techniques. The turbulent line burner facility fitted with the water mist improvements were applied to suppress a 50 kW methane flame. Species-based calorimetry was used to evaluate the global heat release rate and combustion efficiency to evaluate suppression behavior. Detailed local measurements of flame temperature were also performed and provide a useful data set for the evaluation of flame suppression response and for the validation of CFD fire models.","abstract_html":"An experimental study of water mist fire suppression in a buoyant, turbulent diffusion flame is presented. An existing turbulent line burner facility was modified to allow for water mist suppression. These modifications include streamlining the oxidizer delivery system, facility improvements to increase mist generation efficiency, as well as the addition of a mist containment system and an enhanced exhaust flow to homogenize the water mist in the flame region and reduce secondary flows. Following these improvements, the capabilities of the water mist generation system were characterized both using a classical mass balance approach and using more modern advanced diagnostic techniques. The turbulent line burner facility fitted with the water mist improvements were applied to suppress a 50 kW methane flame. Species-based calorimetry was used to evaluate the global heat release rate and combustion efficiency to evaluate suppression behavior. Detailed local measurements of flame temperature were also performed and provide a useful data set for the evaluation of flame suppression response and for the validation of CFD fire models.","abstract_has_math":false,"creators":["Keller, Elizabeth"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Marshall, Andre W"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T08:50:03Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/19098"],"render_values":[{"text":"http://hdl.handle.net/1903/19098","href":"https://hdl.handle.net/1903/19098","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/M22V7J","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/M22V7J","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F19098","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F19098","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marshall, Andre W"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Keller, Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-25T06:40:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-25T06:40:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["extinction","mass loading","temperature","turbulent flame","turbulent line burner","water mist"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/M22V7J"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/19098"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental study of water mist fire suppression in a buoyant, turbulent diffusion flame is presented. An existing turbulent line burner facility was modified to allow for water mist suppression. These modifications include streamlining the oxidizer delivery system, facility improvements to increase mist generation efficiency, as well as the addition of a mist containment system and an enhanced exhaust flow to homogenize the water mist in the flame region and reduce secondary flows. Following these improvements, the capabilities of the water mist generation system were characterized both using a classical mass balance approach and using more modern advanced diagnostic techniques. The turbulent line burner facility fitted with the water mist improvements were applied to suppress a 50 kW methane flame. Species-based calorimetry was used to evaluate the global heat release rate and combustion efficiency to evaluate suppression behavior. Detailed local measurements of flame temperature were also performed and provide a useful data set for the evaluation of flame suppression response and for the validation of CFD fire models."]},{"key":"dc:title","label":"Title","values":["Water Mist Suppression in a Turbulent Line Burner"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marshall, Andre W"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Keller, Elizabeth"],"dc:date.accessioned":["2017-01-25T06:40:58Z"],"dc:date.available":["2017-01-25T06:40:58Z"],"dc:date.issued":["2016"],"dc:description.abstract":["An experimental study of water mist fire suppression in a buoyant, turbulent diffusion flame is presented. An existing turbulent line burner facility was modified to allow for water mist suppression. These modifications include streamlining the oxidizer delivery system, facility improvements to increase mist generation efficiency, as well as the addition of a mist containment system and an enhanced exhaust flow to homogenize the water mist in the flame region and reduce secondary flows. Following these improvements, the capabilities of the water mist generation system were characterized both using a classical mass balance approach and using more modern advanced diagnostic techniques. The turbulent line burner facility fitted with the water mist improvements were applied to suppress a 50 kW methane flame. Species-based calorimetry was used to evaluate the global heat release rate and combustion efficiency to evaluate suppression behavior. Detailed local measurements of flame temperature were also performed and provide a useful data set for the evaluation of flame suppression response and for the validation of CFD fire models."],"dc:identifier":["https://doi.org/10.13016/M22V7J"],"dc:identifier.uri":["http://hdl.handle.net/1903/19098"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["extinction","mass loading","temperature","turbulent flame","turbulent line burner","water mist"],"dc:subject.proquest":["Engineering"],"dc:title":["Water Mist Suppression in a Turbulent Line Burner"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:03Z"}