{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/20028"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/20028","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Thermal Characterization of Firebrand Piles","abstract":"Over the past several decades, the severity of wildland-urban interface (WUI) fires has increased drastically, resulting in thousands of structures lost globally each year. The cause of the majority of structure losses is ignition via firebrands, small pieces of burning material which are generated from burning vegetation and structures. In this thesis, a methodology for studying the heating to recipient fuels by firebrands is developed. Small-scale experiments designed to capture heating from firebrand piles and the process of ignition were conducted using laboratory-fabricated cylindrical wooden firebrands. The methodology compares two heat flux measurement methods. Experimental results compare the effects of varying firebrand diameter, pile mass, and wind speed. An ignition condition is described using temperature and heat flux.","abstract_html":"Over the past several decades, the severity of wildland-urban interface (WUI) fires has increased drastically, resulting in thousands of structures lost globally each year. The cause of the majority of structure losses is ignition via firebrands, small pieces of burning material which are generated from burning vegetation and structures. In this thesis, a methodology for studying the heating to recipient fuels by firebrands is developed. Small-scale experiments designed to capture heating from firebrand piles and the process of ignition were conducted using laboratory-fabricated cylindrical wooden firebrands. The methodology compares two heat flux measurement methods. Experimental results compare the effects of varying firebrand diameter, pile mass, and wind speed. An ignition condition is described using temperature and heat flux.","abstract_has_math":false,"creators":["Hakes, Raquel Sara Pilar"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Gollner, Michael J"],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T08:48:37Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/20028"],"render_values":[{"text":"http://hdl.handle.net/1903/20028","href":"https://hdl.handle.net/1903/20028","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/M2H70814D","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/M2H70814D","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F20028","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F20028","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gollner, Michael J"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Hakes, Raquel Sara Pilar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-09-14T05:49:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-14T05:49:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Burning embers","Firebrands","Heat transfer","Wildfire","Wildland fire"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/M2H70814D"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/20028"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Over the past several decades, the severity of wildland-urban interface (WUI) fires has increased drastically, resulting in thousands of structures lost globally each year. The cause of the majority of structure losses is ignition via firebrands, small pieces of burning material which are generated from burning vegetation and structures. In this thesis, a methodology for studying the heating to recipient fuels by firebrands is developed. Small-scale experiments designed to capture heating from firebrand piles and the process of ignition were conducted using laboratory-fabricated cylindrical wooden firebrands. The methodology compares two heat flux measurement methods. Experimental results compare the effects of varying firebrand diameter, pile mass, and wind speed. An ignition condition is described using temperature and heat flux."]},{"key":"dc:title","label":"Title","values":["Thermal Characterization of Firebrand Piles"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gollner, Michael J"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Hakes, Raquel Sara Pilar"],"dc:date.accessioned":["2017-09-14T05:49:04Z"],"dc:date.available":["2017-09-14T05:49:04Z"],"dc:date.issued":["2017"],"dc:description.abstract":["Over the past several decades, the severity of wildland-urban interface (WUI) fires has increased drastically, resulting in thousands of structures lost globally each year. The cause of the majority of structure losses is ignition via firebrands, small pieces of burning material which are generated from burning vegetation and structures. In this thesis, a methodology for studying the heating to recipient fuels by firebrands is developed. Small-scale experiments designed to capture heating from firebrand piles and the process of ignition were conducted using laboratory-fabricated cylindrical wooden firebrands. The methodology compares two heat flux measurement methods. Experimental results compare the effects of varying firebrand diameter, pile mass, and wind speed. An ignition condition is described using temperature and heat flux."],"dc:identifier":["https://doi.org/10.13016/M2H70814D"],"dc:identifier.uri":["http://hdl.handle.net/1903/20028"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["Burning embers","Firebrands","Heat transfer","Wildfire","Wildland fire"],"dc:subject.proquest":["Engineering"],"dc:title":["Thermal Characterization of Firebrand Piles"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:48:37Z"}