{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/21708"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/21708","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"INFLUENCE OF USING BONDING AGENT AND SHEAR STUDS ON BOND STRENGTH OF CONCRETE OVERLAYS ON PRESTRESSED SLABS","abstract":"This study explores the effects of using bonding agent and shear studs in conjunction with a defined surface roughness condition on the bond strength of concrete overlays poured over prestressed concrete slabs. The shear bond and tensile bond strengths are tested for seven cases by using Double-L test and Split-Prism test respectively. The test variables are surface roughness, use of slurry mix, commercial bonding agent and shear studs at the interface. Application of grooves on the substrate provides a good bond owing to an interlocking effect. Application of bonding agent results in the lowest bond strengths by introduction of a plane of weakness. The bond strength values where shear studs are used are the highest of all test cases. Based on the findings from this study, a recommendation is made to Maryland Department of Transportation to use precast panels with pre-existing grooves and simply pour the overlay concrete on top.","abstract_html":"This study explores the effects of using bonding agent and shear studs in conjunction with a defined surface roughness condition on the bond strength of concrete overlays poured over prestressed concrete slabs. The shear bond and tensile bond strengths are tested for seven cases by using Double-L test and Split-Prism test respectively. The test variables are surface roughness, use of slurry mix, commercial bonding agent and shear studs at the interface. Application of grooves on the substrate provides a good bond owing to an interlocking effect. Application of bonding agent results in the lowest bond strengths by introduction of a plane of weakness. The bond strength values where shear studs are used are the highest of all test cases. Based on the findings from this study, a recommendation is made to Maryland Department of Transportation to use precast panels with pre-existing grooves and simply pour the overlay concrete on top.","abstract_has_math":false,"creators":["Sharma, Shubham"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":["Amde, Amde M."],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T08:50:55Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/21708"],"render_values":[{"text":"http://hdl.handle.net/1903/21708","href":"https://hdl.handle.net/1903/21708","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/3hmi-rbh4","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/3hmi-rbh4","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F21708","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F21708","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Amde, Amde M."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Sharma, Shubham"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-02-05T06:36:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-02-05T06:36:26Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/3hmi-rbh4"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/21708"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study explores the effects of using bonding agent and shear studs in conjunction with a defined surface roughness condition on the bond strength of concrete overlays poured over prestressed concrete slabs. The shear bond and tensile bond strengths are tested for seven cases by using Double-L test and Split-Prism test respectively. The test variables are surface roughness, use of slurry mix, commercial bonding agent and shear studs at the interface. Application of grooves on the substrate provides a good bond owing to an interlocking effect. Application of bonding agent results in the lowest bond strengths by introduction of a plane of weakness. The bond strength values where shear studs are used are the highest of all test cases. Based on the findings from this study, a recommendation is made to Maryland Department of Transportation to use precast panels with pre-existing grooves and simply pour the overlay concrete on top."]},{"key":"dc:title","label":"Title","values":["INFLUENCE OF USING BONDING AGENT AND SHEAR STUDS ON BOND STRENGTH OF CONCRETE OVERLAYS ON PRESTRESSED SLABS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Amde, Amde M."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Sharma, Shubham"],"dc:date.accessioned":["2019-02-05T06:36:26Z"],"dc:date.available":["2019-02-05T06:36:26Z"],"dc:date.issued":["2018"],"dc:description.abstract":["This study explores the effects of using bonding agent and shear studs in conjunction with a defined surface roughness condition on the bond strength of concrete overlays poured over prestressed concrete slabs. The shear bond and tensile bond strengths are tested for seven cases by using Double-L test and Split-Prism test respectively. The test variables are surface roughness, use of slurry mix, commercial bonding agent and shear studs at the interface. Application of grooves on the substrate provides a good bond owing to an interlocking effect. Application of bonding agent results in the lowest bond strengths by introduction of a plane of weakness. The bond strength values where shear studs are used are the highest of all test cases. Based on the findings from this study, a recommendation is made to Maryland Department of Transportation to use precast panels with pre-existing grooves and simply pour the overlay concrete on top."],"dc:identifier":["https://doi.org/10.13016/3hmi-rbh4"],"dc:identifier.uri":["http://hdl.handle.net/1903/21708"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Engineering"],"dc:title":["INFLUENCE OF USING BONDING AGENT AND SHEAR STUDS ON BOND STRENGTH OF CONCRETE OVERLAYS ON PRESTRESSED SLABS"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:55Z"}