{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/2187"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/2187","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"PERFORMANCE AND ENVIRONMENTAL ACCOUNTING OF AIR BIOFILTRATION FOR CARBON MONOXIDE REMOVAL","abstract":"The ability of air biofilters to remove carbon monoxide (CO), a priority pollutant that harms human and environmental health was investigated. Environmental accounting of biofilters was performed using emergy analysis to compare resource requirements of biofilters to catalytic converters. Cylindrical PVC biofilters were filled with pebbles or compost, inoculated with soil slurries and loaded with either bottled CO or engine exhaust CO. In batch experiments, compost and pebble biofilters exhibited exponential decrease in CO over time with compost removing 90% of 1000 ppm-bottled CO and pebble biofilters removing 80% CO in 24 hours. In continuous flow experiments, compost biofilter exposed to 1000 ppm-CO generated from a gasoline engine was able to reduce CO levels (45%) at efficiency commensurate to a bottled CO source. In the range of 500-1000 ppm-CO, biofilters used less total environmental and energy resources to remove CO (12E9 solar emjoules) than conventional catalytic converters (40E9 solar emjoules).","abstract_html":"The ability of air biofilters to remove carbon monoxide (CO), a priority pollutant that harms human and environmental health was investigated. Environmental accounting of biofilters was performed using emergy analysis to compare resource requirements of biofilters to catalytic converters. Cylindrical PVC biofilters were filled with pebbles or compost, inoculated with soil slurries and loaded with either bottled CO or engine exhaust CO. In batch experiments, compost and pebble biofilters exhibited exponential decrease in CO over time with compost removing 90% of 1000 ppm-bottled CO and pebble biofilters removing 80% CO in 24 hours. In continuous flow experiments, compost biofilter exposed to 1000 ppm-CO generated from a gasoline engine was able to reduce CO levels (45%) at efficiency commensurate to a bottled CO source. In the range of 500-1000 ppm-CO, biofilters used less total environmental and energy resources to remove CO (12E9 solar emjoules) than conventional catalytic converters (40E9 solar emjoules).","abstract_has_math":false,"creators":["Ganeshan, Priti"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biological Resources Engineering","school":null,"contributors":[],"advisors":["TILLEY, DAVID R"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-01-18","date_published":"2005-01-18","updated_at":"2026-11-19T08:50:55Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/2187","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/2187","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F2187","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F2187","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["TILLEY, DAVID R"]},{"key":"dc:contributor.department","label":"Department","values":["Biological Resources Engineering"]},{"key":"dc:creator","label":"Author","values":["Ganeshan, Priti"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-02-02T07:02:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-02-02T07:02:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-01-18"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["CARBON MONOXIDE","BIOFILTRATION","EMERGY","ENVIRONMENTAL ACCOUNTING"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Environmental"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/2187"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The ability of air biofilters to remove carbon monoxide (CO), a priority pollutant that harms human and environmental health was investigated. Environmental accounting of biofilters was performed using emergy analysis to compare resource requirements of biofilters to catalytic converters. Cylindrical PVC biofilters were filled with pebbles or compost, inoculated with soil slurries and loaded with either bottled CO or engine exhaust CO. In batch experiments, compost and pebble biofilters exhibited exponential decrease in CO over time with compost removing 90% of 1000 ppm-bottled CO and pebble biofilters removing 80% CO in 24 hours. In continuous flow experiments, compost biofilter exposed to 1000 ppm-CO generated from a gasoline engine was able to reduce CO levels (45%) at efficiency commensurate to a bottled CO source. In the range of 500-1000 ppm-CO, biofilters used less total environmental and energy resources to remove CO (12E9 solar emjoules) than conventional catalytic converters (40E9 solar emjoules)."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1690625 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["PERFORMANCE AND ENVIRONMENTAL ACCOUNTING OF AIR BIOFILTRATION FOR CARBON MONOXIDE REMOVAL"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["TILLEY, DAVID R"],"dc:contributor.department":["Biological Resources Engineering"],"dc:creator":["Ganeshan, Priti"],"dc:date.accessioned":["2005-02-02T07:02:22Z"],"dc:date.available":["2005-02-02T07:02:22Z"],"dc:date.issued":["2005-01-18"],"dc:description.abstract":["The ability of air biofilters to remove carbon monoxide (CO), a priority pollutant that harms human and environmental health was investigated. Environmental accounting of biofilters was performed using emergy analysis to compare resource requirements of biofilters to catalytic converters. Cylindrical PVC biofilters were filled with pebbles or compost, inoculated with soil slurries and loaded with either bottled CO or engine exhaust CO. In batch experiments, compost and pebble biofilters exhibited exponential decrease in CO over time with compost removing 90% of 1000 ppm-bottled CO and pebble biofilters removing 80% CO in 24 hours. In continuous flow experiments, compost biofilter exposed to 1000 ppm-CO generated from a gasoline engine was able to reduce CO levels (45%) at efficiency commensurate to a bottled CO source. In the range of 500-1000 ppm-CO, biofilters used less total environmental and energy resources to remove CO (12E9 solar emjoules) than conventional catalytic converters (40E9 solar emjoules)."],"dc:format.extent":["1690625 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/2187"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["CARBON MONOXIDE","BIOFILTRATION","EMERGY","ENVIRONMENTAL ACCOUNTING"],"dc:subject.proquest":["Engineering, Environmental"],"dc:title":["PERFORMANCE AND ENVIRONMENTAL ACCOUNTING OF AIR BIOFILTRATION FOR CARBON MONOXIDE REMOVAL"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:55Z"}