{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/30734"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/30734","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Development of the Cold Atom Vacuum Standard","abstract":"We describe the inception, design, development, and initial results of The Cold Atom Vacuum Standard (CAVS). It has been known for many years that vacuum level limits the lifetime of a cold atom cloud; we invert this to create a vacuum pressure measurement tool based on the trapped cloud lifetime. The difference between a standard and a sensor is of great concern to metrologists: a primary standard defines a unit, and a sensor transduces it. To have a device capable of both functions is to have a calibration-free measurement tool, which is of interest to many stakeholders in academia, industry, and defense. We describe all aspects of construction of the CAVS, including a lengthy investigation of vacuum technology. We ultimately demonstrate that the device is traceable to pressure through the fundamental physics of collision cross sections, thereby elevating it to status as not just a sensor, but a standard.","abstract_html":"We describe the inception, design, development, and initial results of The Cold Atom Vacuum Standard (CAVS). It has been known for many years that vacuum level limits the lifetime of a cold atom cloud; we invert this to create a vacuum pressure measurement tool based on the trapped cloud lifetime. The difference between a standard and a sensor is of great concern to metrologists: a primary standard defines a unit, and a sensor transduces it. To have a device capable of both functions is to have a calibration-free measurement tool, which is of interest to many stakeholders in academia, industry, and defense. We describe all aspects of construction of the CAVS, including a lengthy investigation of vacuum technology. We ultimately demonstrate that the device is traceable to pressure through the fundamental physics of collision cross sections, thereby elevating it to status as not just a sensor, but a standard.","abstract_has_math":false,"creators":["Scherschligt, Julia"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Porto, Trey","Rolston, Steven"],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T08:55:25Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/30734"],"render_values":[{"text":"http://hdl.handle.net/1903/30734","href":"https://hdl.handle.net/1903/30734","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/dspace/s5zz-xeuw","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/dspace/s5zz-xeuw","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F30734","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F30734","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Porto, Trey","Rolston, Steven"]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Scherschligt, Julia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-10-06T05:35:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-10-06T05:35:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["cold atom","metrology","standard","vacuum"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Atomic physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/dspace/s5zz-xeuw"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/30734"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["We describe the inception, design, development, and initial results of The Cold Atom Vacuum Standard (CAVS). It has been known for many years that vacuum level limits the lifetime of a cold atom cloud; we invert this to create a vacuum pressure measurement tool based on the trapped cloud lifetime. The difference between a standard and a sensor is of great concern to metrologists: a primary standard defines a unit, and a sensor transduces it. To have a device capable of both functions is to have a calibration-free measurement tool, which is of interest to many stakeholders in academia, industry, and defense. We describe all aspects of construction of the CAVS, including a lengthy investigation of vacuum technology. We ultimately demonstrate that the device is traceable to pressure through the fundamental physics of collision cross sections, thereby elevating it to status as not just a sensor, but a standard."]},{"key":"dc:title","label":"Title","values":["Development of the Cold Atom Vacuum Standard"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Porto, Trey","Rolston, Steven"],"dc:contributor.department":["Physics"],"dc:creator":["Scherschligt, Julia"],"dc:date.accessioned":["2023-10-06T05:35:18Z"],"dc:date.available":["2023-10-06T05:35:18Z"],"dc:date.issued":["2023"],"dc:description.abstract":["We describe the inception, design, development, and initial results of The Cold Atom Vacuum Standard (CAVS). It has been known for many years that vacuum level limits the lifetime of a cold atom cloud; we invert this to create a vacuum pressure measurement tool based on the trapped cloud lifetime. The difference between a standard and a sensor is of great concern to metrologists: a primary standard defines a unit, and a sensor transduces it. To have a device capable of both functions is to have a calibration-free measurement tool, which is of interest to many stakeholders in academia, industry, and defense. We describe all aspects of construction of the CAVS, including a lengthy investigation of vacuum technology. We ultimately demonstrate that the device is traceable to pressure through the fundamental physics of collision cross sections, thereby elevating it to status as not just a sensor, but a standard."],"dc:identifier":["https://doi.org/10.13016/dspace/s5zz-xeuw"],"dc:identifier.uri":["http://hdl.handle.net/1903/30734"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["cold atom","metrology","standard","vacuum"],"dc:subject.proquest":["Atomic physics"],"dc:title":["Development of the Cold Atom Vacuum Standard"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:55:25Z"}