{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/3085"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/3085","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Performance Investigation of CHP Equipment","abstract":"The Cooling Heating & Power systems for Buildings (BCHP) are attracting more attention due to their advantages as compared to conventional energy systems. As a developing technology, there are still problems to be solved. Fuel flexibility and dynamic response between different machines in the system are two of the main issues to be investigated. This study presents research conducted on a BCHP system that is composed of a microturbine, an absorption chiller and a solid desiccant unit that are driven by the microturbine's exhaust gas to provide cooling and dehumidification. It demonstrates the feasibility of operating the microturbine that is originally designed for natural gas on propane and analyzes the reasons for the efficiency reduction when operating on propane. It further presents a model that describes the transient behavior of the absorption chiller, which requires a much longer period to reach its steady state compared with the microturbine.","abstract_html":"The Cooling Heating &amp; Power systems for Buildings (BCHP) are attracting more attention due to their advantages as compared to conventional energy systems. As a developing technology, there are still problems to be solved. Fuel flexibility and dynamic response between different machines in the system are two of the main issues to be investigated. This study presents research conducted on a BCHP system that is composed of a microturbine, an absorption chiller and a solid desiccant unit that are driven by the microturbine&#x27;s exhaust gas to provide cooling and dehumidification. It demonstrates the feasibility of operating the microturbine that is originally designed for natural gas on propane and analyzes the reasons for the efficiency reduction when operating on propane. It further presents a model that describes the transient behavior of the absorption chiller, which requires a much longer period to reach its steady state compared with the microturbine.","abstract_has_math":false,"creators":["Bian, Ji"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Radermacher, Reinhard"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-11-03","date_published":"2005-11-03","updated_at":"2026-11-19T08:48:03Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/3085","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/3085","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F3085","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F3085","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Radermacher, Reinhard"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bian, Ji"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-02-04T06:47:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-02-04T06:47:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-11-03"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["CHP","microturbine","absorption chiller"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/3085"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Cooling Heating & Power systems for Buildings (BCHP) are attracting more attention due to their advantages as compared to conventional energy systems. As a developing technology, there are still problems to be solved. Fuel flexibility and dynamic response between different machines in the system are two of the main issues to be investigated. This study presents research conducted on a BCHP system that is composed of a microturbine, an absorption chiller and a solid desiccant unit that are driven by the microturbine's exhaust gas to provide cooling and dehumidification. It demonstrates the feasibility of operating the microturbine that is originally designed for natural gas on propane and analyzes the reasons for the efficiency reduction when operating on propane. It further presents a model that describes the transient behavior of the absorption chiller, which requires a much longer period to reach its steady state compared with the microturbine."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3513073 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Performance Investigation of CHP Equipment"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Radermacher, Reinhard"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Bian, Ji"],"dc:date.accessioned":["2006-02-04T06:47:07Z"],"dc:date.available":["2006-02-04T06:47:07Z"],"dc:date.issued":["2005-11-03"],"dc:description.abstract":["The Cooling Heating & Power systems for Buildings (BCHP) are attracting more attention due to their advantages as compared to conventional energy systems. As a developing technology, there are still problems to be solved. Fuel flexibility and dynamic response between different machines in the system are two of the main issues to be investigated. This study presents research conducted on a BCHP system that is composed of a microturbine, an absorption chiller and a solid desiccant unit that are driven by the microturbine's exhaust gas to provide cooling and dehumidification. It demonstrates the feasibility of operating the microturbine that is originally designed for natural gas on propane and analyzes the reasons for the efficiency reduction when operating on propane. It further presents a model that describes the transient behavior of the absorption chiller, which requires a much longer period to reach its steady state compared with the microturbine."],"dc:format.extent":["3513073 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/3085"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["CHP","microturbine","absorption chiller"],"dc:subject.proquest":["Engineering, Mechanical"],"dc:title":["Performance Investigation of CHP Equipment"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:48:03Z"}