{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/3262"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/3262","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"MODELING AND EXPERIMENTS ON INJECTION INTO UNIVERSITY OF MARYLAND ELECTRON RING","abstract":"The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the earth's magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This thesis presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues.","abstract_html":"The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the earth&#x27;s magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This thesis presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues.","abstract_has_math":false,"creators":["Bai, Gang"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["O'Shea, Patrick"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-12-12","date_published":"2005-12-12","updated_at":"2026-11-19T08:52:33Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/3262","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/3262","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F3262","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F3262","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["O'Shea, Patrick"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bai, Gang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-02-04T07:59:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-02-04T07:59:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-12-12"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Electronics and Electrical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/3262"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the earth's magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This thesis presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1112935 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["MODELING AND EXPERIMENTS ON INJECTION INTO UNIVERSITY OF MARYLAND ELECTRON RING"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["O'Shea, Patrick"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Bai, Gang"],"dc:date.accessioned":["2006-02-04T07:59:29Z"],"dc:date.available":["2006-02-04T07:59:29Z"],"dc:date.issued":["2005-12-12"],"dc:description.abstract":["The University of Maryland Electron Ring (UMER) is built as a low-cost testbed for intense beam physics for benefit of larger ion accelerators. The beam intensity is designed to be variable, spanning the entire range from low current operation to highly space-charge-dominated transport. The ring has been closed and multi-turn commissioning has begun. One of the biggest challenges of multi-turn operation of UMER is correctly operating the Y-shaped injection/recirculation section, which is specially designed for UMER multi-turn operation. It is a challenge because the system requires several quadrupoles and dipoles in a very stringent space, resulting in mechanical, electrical, and beam control complexities. Also, the earth's magnetic field and the image charge effects have to be investigated because they are strong enough to impact the beam centroid motion. This thesis presents both simulation and experimental study of the beam centroid motion in the injection region to address above issues."],"dc:format.extent":["1112935 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/3262"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Engineering, Electronics and Electrical"],"dc:title":["MODELING AND EXPERIMENTS ON INJECTION INTO UNIVERSITY OF MARYLAND ELECTRON RING"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:52:33Z"}