{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/3280"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/3280","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"FLAMMABILITY CHARACTERISTICS OF WATER-BASED POLYCRYLIC AND OIL-BASED POLYURETHANE COATED OAK VENEER PLYWOOD SAMPLES SUBJECTED TO INCIDENT HEAT FLUXES","abstract":"The flammability characteristics of oak veneer plywood were evaluated in the Cone Calorimeter. Samples of 6.35 mm (1/4 in.) thick and 19.05 mm (3/4 in.) thick oak veneer plywood were coated with 3, 6, and 9 coats of either oil-based polyurethane or water-based polycrylic clear finishes and tested at incident heat fluxes of 35, 50, and 75 kW/m2 along with uncoated samples. Both the type of finish and the number of coatings were found to influence the ignition time, the measured peak heat release rate, and the minimum flux for ignition of the samples. The ignition times for the coated samples were 2 to 3 times lower than the unfinished samples. Predicted times to ignition differed by a factor of 2 to 3 from the measured values (with the exception of the samples with nine coats of finish.) The predicted ignition temperatures differed by as much as 100 ºC from the measured temperatures. The Quintiere flammability parameter, b, was found to be positive for all testing scenarios, suggesting a propensity for flame spread at the incident heat fluxes evaluated.","abstract_html":"The flammability characteristics of oak veneer plywood were evaluated in the Cone Calorimeter. Samples of 6.35 mm (1/4 in.) thick and 19.05 mm (3/4 in.) thick oak veneer plywood were coated with 3, 6, and 9 coats of either oil-based polyurethane or water-based polycrylic clear finishes and tested at incident heat fluxes of 35, 50, and 75 kW/m2 along with uncoated samples. Both the type of finish and the number of coatings were found to influence the ignition time, the measured peak heat release rate, and the minimum flux for ignition of the samples. The ignition times for the coated samples were 2 to 3 times lower than the unfinished samples. Predicted times to ignition differed by a factor of 2 to 3 from the measured values (with the exception of the samples with nine coats of finish.) The predicted ignition temperatures differed by as much as 100 ºC from the measured temperatures. The Quintiere flammability parameter, b, was found to be positive for all testing scenarios, suggesting a propensity for flame spread at the incident heat fluxes evaluated.","abstract_has_math":false,"creators":["Thompson, Sarah Elizabeth"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Mowrer, Frederick W."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-12-13","date_published":"2005-12-13","updated_at":"2026-11-19T08:43:15Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/3280","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/3280","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F3280","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F3280","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mowrer, Frederick W."]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Thompson, Sarah Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-02-04T08:07:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-02-04T08:07:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2005-12-13"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["calorimetry","flammability","heat release rate","ignition","interior finish","plywood"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/3280"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The flammability characteristics of oak veneer plywood were evaluated in the Cone Calorimeter. Samples of 6.35 mm (1/4 in.) thick and 19.05 mm (3/4 in.) thick oak veneer plywood were coated with 3, 6, and 9 coats of either oil-based polyurethane or water-based polycrylic clear finishes and tested at incident heat fluxes of 35, 50, and 75 kW/m2 along with uncoated samples. Both the type of finish and the number of coatings were found to influence the ignition time, the measured peak heat release rate, and the minimum flux for ignition of the samples. The ignition times for the coated samples were 2 to 3 times lower than the unfinished samples. Predicted times to ignition differed by a factor of 2 to 3 from the measured values (with the exception of the samples with nine coats of finish.) The predicted ignition temperatures differed by as much as 100 ºC from the measured temperatures. The Quintiere flammability parameter, b, was found to be positive for all testing scenarios, suggesting a propensity for flame spread at the incident heat fluxes evaluated."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1602837 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["FLAMMABILITY CHARACTERISTICS OF WATER-BASED POLYCRYLIC AND OIL-BASED POLYURETHANE COATED OAK VENEER PLYWOOD SAMPLES SUBJECTED TO INCIDENT HEAT FLUXES"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mowrer, Frederick W."],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Thompson, Sarah Elizabeth"],"dc:date.accessioned":["2006-02-04T08:07:30Z"],"dc:date.available":["2006-02-04T08:07:30Z"],"dc:date.issued":["2005-12-13"],"dc:description.abstract":["The flammability characteristics of oak veneer plywood were evaluated in the Cone Calorimeter. Samples of 6.35 mm (1/4 in.) thick and 19.05 mm (3/4 in.) thick oak veneer plywood were coated with 3, 6, and 9 coats of either oil-based polyurethane or water-based polycrylic clear finishes and tested at incident heat fluxes of 35, 50, and 75 kW/m2 along with uncoated samples. Both the type of finish and the number of coatings were found to influence the ignition time, the measured peak heat release rate, and the minimum flux for ignition of the samples. The ignition times for the coated samples were 2 to 3 times lower than the unfinished samples. Predicted times to ignition differed by a factor of 2 to 3 from the measured values (with the exception of the samples with nine coats of finish.) The predicted ignition temperatures differed by as much as 100 ºC from the measured temperatures. The Quintiere flammability parameter, b, was found to be positive for all testing scenarios, suggesting a propensity for flame spread at the incident heat fluxes evaluated."],"dc:format.extent":["1602837 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/3280"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["calorimetry","flammability","heat release rate","ignition","interior finish","plywood"],"dc:subject.proquest":["Engineering, General"],"dc:title":["FLAMMABILITY CHARACTERISTICS OF WATER-BASED POLYCRYLIC AND OIL-BASED POLYURETHANE COATED OAK VENEER PLYWOOD SAMPLES SUBJECTED TO INCIDENT HEAT FLUXES"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:43:15Z"}