{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/3602"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/3602","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Thin-Filament Pyrometry with a Digital Still Camera","abstract":"A novel thin-filament pyrometer is presented here. It involves a consumer-grade color digital still camera with a charged-couple device sensor with 3008 X 2000 pixels and 12 bits per color plane. A blue Schott filter and custom white balance were used to yield similar red, green and blue intensities along the fibers. SiCO fibers with diameters of 13.9 microns were used and scanning-electron microscopy revealed the fibers to be uniform. Measurements were performed in a methane/air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouple measurements. The camera was found to be well suited to thin-filament pyrometry. The pyrometry measurements yielded gas temperatures in the range of 1350 - 2200 K with an estimated uncertainty of ± 60 K, a relative temperature resolution of ± 0.215 K, a spatial resolution of 42 µm and a temporal resolution of 0.66 ms. Fiber aging had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple.","abstract_html":"A novel thin-filament pyrometer is presented here. It involves a consumer-grade color digital still camera with a charged-couple device sensor with 3008 X 2000 pixels and 12 bits per color plane. A blue Schott filter and custom white balance were used to yield similar red, green and blue intensities along the fibers. SiCO fibers with diameters of 13.9 microns were used and scanning-electron microscopy revealed the fibers to be uniform. Measurements were performed in a methane/air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouple measurements. The camera was found to be well suited to thin-filament pyrometry. The pyrometry measurements yielded gas temperatures in the range of 1350 - 2200 K with an estimated uncertainty of ± 60 K, a relative temperature resolution of ± 0.215 K, a spatial resolution of 42 µm and a temporal resolution of 0.66 ms. Fiber aging had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple.","abstract_has_math":false,"creators":["Maun, Jignesh D"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Sunderland, Peter B"],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006-05-08","date_published":"2006-05-08","updated_at":"2026-11-19T08:45:59Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/3602","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/3602","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F3602","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F3602","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sunderland, Peter B"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Maun, Jignesh D"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-06-14T06:07:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-06-14T06:07:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2006-05-08"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["thin-filament pyrometry","combustion diagnostics","diffusion flame","thermocouple","soot","silicon carbide fibers;"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/3602"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A novel thin-filament pyrometer is presented here. It involves a consumer-grade color digital still camera with a charged-couple device sensor with 3008 X 2000 pixels and 12 bits per color plane. A blue Schott filter and custom white balance were used to yield similar red, green and blue intensities along the fibers. SiCO fibers with diameters of 13.9 microns were used and scanning-electron microscopy revealed the fibers to be uniform. Measurements were performed in a methane/air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouple measurements. The camera was found to be well suited to thin-filament pyrometry. The pyrometry measurements yielded gas temperatures in the range of 1350 - 2200 K with an estimated uncertainty of ± 60 K, a relative temperature resolution of ± 0.215 K, a spatial resolution of 42 µm and a temporal resolution of 0.66 ms. Fiber aging had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1449441 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Thin-Filament Pyrometry with a Digital Still Camera"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sunderland, Peter B"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Maun, Jignesh D"],"dc:date.accessioned":["2006-06-14T06:07:37Z"],"dc:date.available":["2006-06-14T06:07:37Z"],"dc:date.issued":["2006-05-08"],"dc:description.abstract":["A novel thin-filament pyrometer is presented here. It involves a consumer-grade color digital still camera with a charged-couple device sensor with 3008 X 2000 pixels and 12 bits per color plane. A blue Schott filter and custom white balance were used to yield similar red, green and blue intensities along the fibers. SiCO fibers with diameters of 13.9 microns were used and scanning-electron microscopy revealed the fibers to be uniform. Measurements were performed in a methane/air coflowing laminar jet diffusion flame with a luminosity length of 72 mm. Calibration of the pyrometer was accomplished with B-type thermocouple measurements. The camera was found to be well suited to thin-filament pyrometry. The pyrometry measurements yielded gas temperatures in the range of 1350 - 2200 K with an estimated uncertainty of ± 60 K, a relative temperature resolution of ± 0.215 K, a spatial resolution of 42 µm and a temporal resolution of 0.66 ms. Fiber aging had no effect on the results. Soot deposition was less problematic for the pyrometer than for the thermocouple."],"dc:format.extent":["1449441 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/3602"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["thin-filament pyrometry","combustion diagnostics","diffusion flame","thermocouple","soot","silicon carbide fibers;"],"dc:subject.proquest":["Engineering, Mechanical"],"dc:title":["Thin-Filament Pyrometry with a Digital Still Camera"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:45:59Z"}