{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/36233"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/36233","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"SAMPLE PREPARATION FOR POINT-OF-CARE ASSAYS WITH WHOLE BLOOD SAMPLES","abstract":"In recent decades, significant advances have been made in diagnostics, particularly point-of-care diagnostics. Most of these advances have focused on the analytical steps of diagnostics rather than the pre-analytical steps. The pre-analytical steps include sample collection, transit, storage, and sample preparation, with most of these being process issues. However, sample preparation is often an overlooked step in the pre-analytical phase that contributes to the turnaround time of diagnostic assays. Laboratory assays often have long turnaround times because they rely on sample preparation in a central laboratory, whereas point-of-care assays could offer a more rapid alternative. Upon review of the literature, many proposed point-of-care assays are not truly point-of-care, nor are they as rapid as they should be when using blood as the sample, since they rely on blood-sample preparation steps that require central laboratories. To truly be point-of-care, whole-blood sample preparation should ideally be performed without requiring central laboratory equipment or personnel, with plasma or serum separation integrated into the point-of-care assay. Three novel whole blood sample preparation strategies are reported in this thesis. Each technique uses a different primary mechanism. The first technique uses agglomeration agents to promote red blood cell removal for optically based homogeneous assays. The second technique uses a two-stage filter cassette to convert blood to serum for fluorescence assays. Finally, the third strategy uses acid digestion and filtration to lyse red blood cells and coagulate debris for point-of-care lead testing. These blood microsample preparation methods, through their simple operation and rapid conversion of whole blood to a prepared sample, have the potential to greatly advance the pre-analytical phase of point-of-care assays.","abstract_html":"In recent decades, significant advances have been made in diagnostics, particularly point-of-care diagnostics. Most of these advances have focused on the analytical steps of diagnostics rather than the pre-analytical steps. The pre-analytical steps include sample collection, transit, storage, and sample preparation, with most of these being process issues. However, sample preparation is often an overlooked step in the pre-analytical phase that contributes to the turnaround time of diagnostic assays. Laboratory assays often have long turnaround times because they rely on sample preparation in a central laboratory, whereas point-of-care assays could offer a more rapid alternative. Upon review of the literature, many proposed point-of-care assays are not truly point-of-care, nor are they as rapid as they should be when using blood as the sample, since they rely on blood-sample preparation steps that require central laboratories. To truly be point-of-care, whole-blood sample preparation should ideally be performed without requiring central laboratory equipment or personnel, with plasma or serum separation integrated into the point-of-care assay. Three novel whole blood sample preparation strategies are reported in this thesis. Each technique uses a different primary mechanism. The first technique uses agglomeration agents to promote red blood cell removal for optically based homogeneous assays. The second technique uses a two-stage filter cassette to convert blood to serum for fluorescence assays. Finally, the third strategy uses acid digestion and filtration to lyse red blood cells and coagulate debris for point-of-care lead testing. These blood microsample preparation methods, through their simple operation and rapid conversion of whole blood to a prepared sample, have the potential to greatly advance the pre-analytical phase of point-of-care assays.","abstract_has_math":false,"creators":["Pueschel, Alexander Ryan"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Bioengineering","school":null,"contributors":[],"advisors":["White, Ian M"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T08:48:12Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/36233"],"render_values":[{"text":"http://hdl.handle.net/1903/36233","href":"https://hdl.handle.net/1903/36233","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.13016/lzaa-zioy","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.13016/lzaa-zioy","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F36233","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F36233","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["White, Ian M"]},{"key":"dc:contributor.department","label":"Department","values":["Bioengineering"]},{"key":"dc:creator","label":"Author","values":["Pueschel, Alexander Ryan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-27T06:00:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Bioengineering","Biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.13016/lzaa-zioy"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/36233"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In recent decades, significant advances have been made in diagnostics, particularly point-of-care diagnostics. Most of these advances have focused on the analytical steps of diagnostics rather than the pre-analytical steps. The pre-analytical steps include sample collection, transit, storage, and sample preparation, with most of these being process issues. However, sample preparation is often an overlooked step in the pre-analytical phase that contributes to the turnaround time of diagnostic assays. Laboratory assays often have long turnaround times because they rely on sample preparation in a central laboratory, whereas point-of-care assays could offer a more rapid alternative. Upon review of the literature, many proposed point-of-care assays are not truly point-of-care, nor are they as rapid as they should be when using blood as the sample, since they rely on blood-sample preparation steps that require central laboratories. To truly be point-of-care, whole-blood sample preparation should ideally be performed without requiring central laboratory equipment or personnel, with plasma or serum separation integrated into the point-of-care assay. Three novel whole blood sample preparation strategies are reported in this thesis. Each technique uses a different primary mechanism. The first technique uses agglomeration agents to promote red blood cell removal for optically based homogeneous assays. The second technique uses a two-stage filter cassette to convert blood to serum for fluorescence assays. Finally, the third strategy uses acid digestion and filtration to lyse red blood cells and coagulate debris for point-of-care lead testing. These blood microsample preparation methods, through their simple operation and rapid conversion of whole blood to a prepared sample, have the potential to greatly advance the pre-analytical phase of point-of-care assays."]},{"key":"dc:title","label":"Title","values":["SAMPLE PREPARATION FOR POINT-OF-CARE ASSAYS WITH WHOLE BLOOD SAMPLES"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["White, Ian M"],"dc:contributor.department":["Bioengineering"],"dc:creator":["Pueschel, Alexander Ryan"],"dc:date.accessioned":["2026-10-27T06:00:06Z"],"dc:date.issued":["2026"],"dc:description.abstract":["In recent decades, significant advances have been made in diagnostics, particularly point-of-care diagnostics. Most of these advances have focused on the analytical steps of diagnostics rather than the pre-analytical steps. The pre-analytical steps include sample collection, transit, storage, and sample preparation, with most of these being process issues. However, sample preparation is often an overlooked step in the pre-analytical phase that contributes to the turnaround time of diagnostic assays. Laboratory assays often have long turnaround times because they rely on sample preparation in a central laboratory, whereas point-of-care assays could offer a more rapid alternative. Upon review of the literature, many proposed point-of-care assays are not truly point-of-care, nor are they as rapid as they should be when using blood as the sample, since they rely on blood-sample preparation steps that require central laboratories. To truly be point-of-care, whole-blood sample preparation should ideally be performed without requiring central laboratory equipment or personnel, with plasma or serum separation integrated into the point-of-care assay. Three novel whole blood sample preparation strategies are reported in this thesis. Each technique uses a different primary mechanism. The first technique uses agglomeration agents to promote red blood cell removal for optically based homogeneous assays. The second technique uses a two-stage filter cassette to convert blood to serum for fluorescence assays. Finally, the third strategy uses acid digestion and filtration to lyse red blood cells and coagulate debris for point-of-care lead testing. These blood microsample preparation methods, through their simple operation and rapid conversion of whole blood to a prepared sample, have the potential to greatly advance the pre-analytical phase of point-of-care assays."],"dc:identifier":["https://doi.org/10.13016/lzaa-zioy"],"dc:identifier.uri":["http://hdl.handle.net/1903/36233"],"dc:language.iso":["en"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Bioengineering","Biomedical engineering"],"dc:title":["SAMPLE PREPARATION FOR POINT-OF-CARE ASSAYS WITH WHOLE BLOOD SAMPLES"],"dc:type":["Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-19T08:48:12Z"}