{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/6983"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/6983","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Development of a display screen correlation metric for thermal imaging cameras","abstract":"Thermal imaging cameras detect infrared radiation to semi-quantitatively determine the thermal profile of the surroundings. Previously, no standard performance measurements have been established for thermal imaging cameras applications such as search and rescue and firefighting. The spatial contrast resolution in realistic atmospheric conditions was assessed through various full scale fires. Absorbing gas-phase combustion products greatly affected the ability of the TIC to measure local contrast in temperatures as a function of spatial frequency. A test was developed using a thermal gradient target to relate the voltage ramp output signal recorded in 8 bit digital tape format to the luminance projected by the LCD screen profile measured by a 16 bit CCD camera array with an IR filter. These relationship were nonlinear and unique to each imager tested. Measurements of the output signal only do not describe the final performance and a complete standard performance evaluation must measure the display luminance.","abstract_html":"Thermal imaging cameras detect infrared radiation to semi-quantitatively determine the thermal profile of the surroundings. Previously, no standard performance measurements have been established for thermal imaging cameras applications such as search and rescue and firefighting. The spatial contrast resolution in realistic atmospheric conditions was assessed through various full scale fires. Absorbing gas-phase combustion products greatly affected the ability of the TIC to measure local contrast in temperatures as a function of spatial frequency. A test was developed using a thermal gradient target to relate the voltage ramp output signal recorded in 8 bit digital tape format to the luminance projected by the LCD screen profile measured by a 16 bit CCD camera array with an IR filter. These relationship were nonlinear and unique to each imager tested. Measurements of the output signal only do not describe the final performance and a complete standard performance evaluation must measure the display luminance.","abstract_has_math":false,"creators":["Dinaburg, Joshua Benjamin"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Jackson, Gregory"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-05-11","date_published":"2007-05-11","updated_at":"2026-11-19T08:43:08Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/6983","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/6983","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F6983","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F6983","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jackson, Gregory"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Dinaburg, Joshua Benjamin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-06-22T05:38:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-06-22T05:38:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-05-11"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["thermal imaging","LCD display","metrology"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/6983"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Thermal imaging cameras detect infrared radiation to semi-quantitatively determine the thermal profile of the surroundings. Previously, no standard performance measurements have been established for thermal imaging cameras applications such as search and rescue and firefighting. The spatial contrast resolution in realistic atmospheric conditions was assessed through various full scale fires. Absorbing gas-phase combustion products greatly affected the ability of the TIC to measure local contrast in temperatures as a function of spatial frequency. A test was developed using a thermal gradient target to relate the voltage ramp output signal recorded in 8 bit digital tape format to the luminance projected by the LCD screen profile measured by a 16 bit CCD camera array with an IR filter. These relationship were nonlinear and unique to each imager tested. Measurements of the output signal only do not describe the final performance and a complete standard performance evaluation must measure the display luminance."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1270457 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of a display screen correlation metric for thermal imaging cameras"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jackson, Gregory"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Dinaburg, Joshua Benjamin"],"dc:date.accessioned":["2007-06-22T05:38:58Z"],"dc:date.available":["2007-06-22T05:38:58Z"],"dc:date.issued":["2007-05-11"],"dc:description.abstract":["Thermal imaging cameras detect infrared radiation to semi-quantitatively determine the thermal profile of the surroundings. Previously, no standard performance measurements have been established for thermal imaging cameras applications such as search and rescue and firefighting. The spatial contrast resolution in realistic atmospheric conditions was assessed through various full scale fires. Absorbing gas-phase combustion products greatly affected the ability of the TIC to measure local contrast in temperatures as a function of spatial frequency. A test was developed using a thermal gradient target to relate the voltage ramp output signal recorded in 8 bit digital tape format to the luminance projected by the LCD screen profile measured by a 16 bit CCD camera array with an IR filter. These relationship were nonlinear and unique to each imager tested. Measurements of the output signal only do not describe the final performance and a complete standard performance evaluation must measure the display luminance."],"dc:format.extent":["1270457 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/6983"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["thermal imaging","LCD display","metrology"],"dc:subject.proquest":["Engineering, Mechanical"],"dc:title":["Development of a display screen correlation metric for thermal imaging cameras"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:43:08Z"}