{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/6998"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/6998","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Thermo-Optic Aspects of Large Screen Plasma Display Panels","abstract":"Plasma Display Panels (PDPs) are a popular technology for large size television displays. Screen inefficiencies, which result in significant localized heat generation, necessitate the use of advanced thermal management materials to reduce the peak temperatures and spatial temperature variations across the screen. In the current study, infrared thermography was used to obtain thermal maps of a typical, 42\", high-definition PDP screen for different illumination patterns and for several configurations of externally controlled heaters simulating PDP heat generation. The results were used to validate a three-dimensional numerical thermal model of the PDP designed to predict the beneficial effects of anisotropic graphite heat spreaders on the temperature distribution. In addition, a color analyzer was used to determine the spatial and temporal variations in luminosity across the PDP when operated continuously for 1750 hours. The thermal model and experimental luminosity characteristics were used to evaluate the deleterious effects of temperature on PDP performance.","abstract_html":"Plasma Display Panels (PDPs) are a popular technology for large size television displays. Screen inefficiencies, which result in significant localized heat generation, necessitate the use of advanced thermal management materials to reduce the peak temperatures and spatial temperature variations across the screen. In the current study, infrared thermography was used to obtain thermal maps of a typical, 42&quot;, high-definition PDP screen for different illumination patterns and for several configurations of externally controlled heaters simulating PDP heat generation. The results were used to validate a three-dimensional numerical thermal model of the PDP designed to predict the beneficial effects of anisotropic graphite heat spreaders on the temperature distribution. In addition, a color analyzer was used to determine the spatial and temporal variations in luminosity across the PDP when operated continuously for 1750 hours. The thermal model and experimental luminosity characteristics were used to evaluate the deleterious effects of temperature on PDP performance.","abstract_has_math":false,"creators":["Kahn, Jeffry Joseph"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Bar-Cohen, Avram"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-05-16","date_published":"2007-05-16","updated_at":"2026-11-19T08:43:19Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/6998","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/6998","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F6998","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F6998","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bar-Cohen, Avram"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Kahn, Jeffry Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-06-22T05:39:19Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-06-22T05:39:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-05-16"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Plasma Display Panel","PDP","Luminosity","Numerical Modeling","Thermal Management","Heat Spreader"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/6998"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Plasma Display Panels (PDPs) are a popular technology for large size television displays. Screen inefficiencies, which result in significant localized heat generation, necessitate the use of advanced thermal management materials to reduce the peak temperatures and spatial temperature variations across the screen. In the current study, infrared thermography was used to obtain thermal maps of a typical, 42\", high-definition PDP screen for different illumination patterns and for several configurations of externally controlled heaters simulating PDP heat generation. The results were used to validate a three-dimensional numerical thermal model of the PDP designed to predict the beneficial effects of anisotropic graphite heat spreaders on the temperature distribution. In addition, a color analyzer was used to determine the spatial and temporal variations in luminosity across the PDP when operated continuously for 1750 hours. The thermal model and experimental luminosity characteristics were used to evaluate the deleterious effects of temperature on PDP performance."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["1568064 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Thermo-Optic Aspects of Large Screen Plasma Display Panels"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bar-Cohen, Avram"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Kahn, Jeffry Joseph"],"dc:date.accessioned":["2007-06-22T05:39:19Z"],"dc:date.available":["2007-06-22T05:39:19Z"],"dc:date.issued":["2007-05-16"],"dc:description.abstract":["Plasma Display Panels (PDPs) are a popular technology for large size television displays. Screen inefficiencies, which result in significant localized heat generation, necessitate the use of advanced thermal management materials to reduce the peak temperatures and spatial temperature variations across the screen. In the current study, infrared thermography was used to obtain thermal maps of a typical, 42\", high-definition PDP screen for different illumination patterns and for several configurations of externally controlled heaters simulating PDP heat generation. The results were used to validate a three-dimensional numerical thermal model of the PDP designed to predict the beneficial effects of anisotropic graphite heat spreaders on the temperature distribution. In addition, a color analyzer was used to determine the spatial and temporal variations in luminosity across the PDP when operated continuously for 1750 hours. The thermal model and experimental luminosity characteristics were used to evaluate the deleterious effects of temperature on PDP performance."],"dc:format.extent":["1568064 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/6998"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["Plasma Display Panel","PDP","Luminosity","Numerical Modeling","Thermal Management","Heat Spreader"],"dc:subject.proquest":["Engineering, Mechanical"],"dc:title":["Thermo-Optic Aspects of Large Screen Plasma Display Panels"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:43:19Z"}