{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7022"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7022","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Development and Testing of a Metabolic Workload Measurement System for Space Suits","abstract":"Real time knowledge of the metabolic workload of an astronaut during an Extra-Vehicular Activity (EVA) can be instrumental for space suit research, design, and operation. Three indirect calorimetry approaches were developed to determine the metabolic workload of a subject in an open-loop space suit analogue. A study was conducted to compare the data obtained from three sensors: oxygen, carbon dioxide, and heart rate. Subjects performed treadmill exercise in an enclosed helmet assembly, which simulated the contained environment of a space suit while retaining arm and leg mobility. These results were validated against a standard system used by exercise physiologists. The carbon dioxide sensor method was shown to be the most reliable and a calibrated version of it is recommended for implementation into the MX-2 neutral buoyancy space suit analogue.","abstract_html":"Real time knowledge of the metabolic workload of an astronaut during an Extra-Vehicular Activity (EVA) can be instrumental for space suit research, design, and operation. Three indirect calorimetry approaches were developed to determine the metabolic workload of a subject in an open-loop space suit analogue. A study was conducted to compare the data obtained from three sensors: oxygen, carbon dioxide, and heart rate. Subjects performed treadmill exercise in an enclosed helmet assembly, which simulated the contained environment of a space suit while retaining arm and leg mobility. These results were validated against a standard system used by exercise physiologists. The carbon dioxide sensor method was shown to be the most reliable and a calibrated version of it is recommended for implementation into the MX-2 neutral buoyancy space suit analogue.","abstract_has_math":false,"creators":["Koscielniak, Agnieszka"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Aerospace Engineering","school":null,"contributors":[],"advisors":["Akin, David L"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-06-05","date_published":"2007-06-05","updated_at":"2026-11-19T08:50:55Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7022","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7022","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F7022","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7022","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Akin, David L"]},{"key":"dc:contributor.department","label":"Department","values":["Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Koscielniak, Agnieszka"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-06-22T05:40:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-06-22T05:40:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-06-05"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["space suit","metabolic workload","oxygen consumption","heart rate","exercise physiology"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Aerospace"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7022"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Real time knowledge of the metabolic workload of an astronaut during an Extra-Vehicular Activity (EVA) can be instrumental for space suit research, design, and operation. Three indirect calorimetry approaches were developed to determine the metabolic workload of a subject in an open-loop space suit analogue. A study was conducted to compare the data obtained from three sensors: oxygen, carbon dioxide, and heart rate. Subjects performed treadmill exercise in an enclosed helmet assembly, which simulated the contained environment of a space suit while retaining arm and leg mobility. These results were validated against a standard system used by exercise physiologists. The carbon dioxide sensor method was shown to be the most reliable and a calibrated version of it is recommended for implementation into the MX-2 neutral buoyancy space suit analogue."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["8906004 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and Testing of a Metabolic Workload Measurement System for Space Suits"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Akin, David L"],"dc:contributor.department":["Aerospace Engineering"],"dc:creator":["Koscielniak, Agnieszka"],"dc:date.accessioned":["2007-06-22T05:40:06Z"],"dc:date.available":["2007-06-22T05:40:06Z"],"dc:date.issued":["2007-06-05"],"dc:description.abstract":["Real time knowledge of the metabolic workload of an astronaut during an Extra-Vehicular Activity (EVA) can be instrumental for space suit research, design, and operation. Three indirect calorimetry approaches were developed to determine the metabolic workload of a subject in an open-loop space suit analogue. A study was conducted to compare the data obtained from three sensors: oxygen, carbon dioxide, and heart rate. Subjects performed treadmill exercise in an enclosed helmet assembly, which simulated the contained environment of a space suit while retaining arm and leg mobility. These results were validated against a standard system used by exercise physiologists. The carbon dioxide sensor method was shown to be the most reliable and a calibrated version of it is recommended for implementation into the MX-2 neutral buoyancy space suit analogue."],"dc:format.extent":["8906004 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7022"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["space suit","metabolic workload","oxygen consumption","heart rate","exercise physiology"],"dc:subject.proquest":["Engineering, Aerospace"],"dc:title":["Development and Testing of a Metabolic Workload Measurement System for Space Suits"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:50:55Z"}