{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7366"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7366","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Design of a dielectrophoretic cell loading device","abstract":"In recent years there has been an increasing interest in studying individual cells, and structures that physically entrap one or few cells have been developed for this purpose, but the approaches to load cells into these structures leave a lot to be desired. This dissertation discusses the design of a device that loads cells suspended in a solution into microvials using a combination of dielectrophoresis and fluid flow, which offers significant advantages over previous loading approaches. The basic concept is to use fluid flow and dielectrophoretic forces to position a given cell above a given vial, within an array of similar vials, and then bringing the cell into the vial. The loading of several cells flowing in a channel into a vial in a matter of seconds is demonstrated. The design of the loading device spurred the development of novel topics in the area of dielectrophoresis. The structures into which cells are loaded produce \"parasitic cages\". The effect of multiple electric fields and at multiple frequencies had to be explored to eliminate the parasitic cages, and new theory was developed to describe the phenomenon in a straight forward and convenient way. The design process of dielectrophoretic structures known as flow through sorters was simplified significantly using a method that relies on non dimensional analysis and a figure of merit. These topics investigated have broader applications than just loading cells into vials. The dissertation demonstrates technologies and design and fabrication methods key to the cell loading design. The dissertation ends by describing the design of a device that can be implemented to load cells into vials on integrated circuit chips and outlining this device's expected characteristics and performance based on the theory and methods presented through the dissertation.","abstract_html":"In recent years there has been an increasing interest in studying individual cells, and structures that physically entrap one or few cells have been developed for this purpose, but the approaches to load cells into these structures leave a lot to be desired. This dissertation discusses the design of a device that loads cells suspended in a solution into microvials using a combination of dielectrophoresis and fluid flow, which offers significant advantages over previous loading approaches. The basic concept is to use fluid flow and dielectrophoretic forces to position a given cell above a given vial, within an array of similar vials, and then bringing the cell into the vial. The loading of several cells flowing in a channel into a vial in a matter of seconds is demonstrated. The design of the loading device spurred the development of novel topics in the area of dielectrophoresis. The structures into which cells are loaded produce &quot;parasitic cages&quot;. The effect of multiple electric fields and at multiple frequencies had to be explored to eliminate the parasitic cages, and new theory was developed to describe the phenomenon in a straight forward and convenient way. The design process of dielectrophoretic structures known as flow through sorters was simplified significantly using a method that relies on non dimensional analysis and a figure of merit. These topics investigated have broader applications than just loading cells into vials. The dissertation demonstrates technologies and design and fabrication methods key to the cell loading design. The dissertation ends by describing the design of a device that can be implemented to load cells into vials on integrated circuit chips and outlining this device&#x27;s expected characteristics and performance based on the theory and methods presented through the dissertation.","abstract_has_math":false,"creators":["Urdaneta, Mario Gustavo"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Smela, Elisabeth"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-09","date_published":"2007-08-09","updated_at":"2026-11-19T08:43:36Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7366","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7366","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F7366","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7366","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Smela, Elisabeth"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Urdaneta, Mario Gustavo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-09-28T15:02:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-09-28T15:02:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-08-09"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["dielectrophoresis","cell manipulation","cell loading","multiple frequency dielectrophoresis","MFDEP","cell cage","cell clinics"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical","Engineering, Biomedical","Engineering, General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7366"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In recent years there has been an increasing interest in studying individual cells, and structures that physically entrap one or few cells have been developed for this purpose, but the approaches to load cells into these structures leave a lot to be desired. This dissertation discusses the design of a device that loads cells suspended in a solution into microvials using a combination of dielectrophoresis and fluid flow, which offers significant advantages over previous loading approaches. The basic concept is to use fluid flow and dielectrophoretic forces to position a given cell above a given vial, within an array of similar vials, and then bringing the cell into the vial. The loading of several cells flowing in a channel into a vial in a matter of seconds is demonstrated. The design of the loading device spurred the development of novel topics in the area of dielectrophoresis. The structures into which cells are loaded produce \"parasitic cages\". The effect of multiple electric fields and at multiple frequencies had to be explored to eliminate the parasitic cages, and new theory was developed to describe the phenomenon in a straight forward and convenient way. The design process of dielectrophoretic structures known as flow through sorters was simplified significantly using a method that relies on non dimensional analysis and a figure of merit. These topics investigated have broader applications than just loading cells into vials. The dissertation demonstrates technologies and design and fabrication methods key to the cell loading design. The dissertation ends by describing the design of a device that can be implemented to load cells into vials on integrated circuit chips and outlining this device's expected characteristics and performance based on the theory and methods presented through the dissertation."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["9180312 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of a dielectrophoretic cell loading device"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Smela, Elisabeth"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Urdaneta, Mario Gustavo"],"dc:date.accessioned":["2007-09-28T15:02:15Z"],"dc:date.available":["2007-09-28T15:02:15Z"],"dc:date.issued":["2007-08-09"],"dc:description.abstract":["In recent years there has been an increasing interest in studying individual cells, and structures that physically entrap one or few cells have been developed for this purpose, but the approaches to load cells into these structures leave a lot to be desired. This dissertation discusses the design of a device that loads cells suspended in a solution into microvials using a combination of dielectrophoresis and fluid flow, which offers significant advantages over previous loading approaches. The basic concept is to use fluid flow and dielectrophoretic forces to position a given cell above a given vial, within an array of similar vials, and then bringing the cell into the vial. The loading of several cells flowing in a channel into a vial in a matter of seconds is demonstrated. The design of the loading device spurred the development of novel topics in the area of dielectrophoresis. The structures into which cells are loaded produce \"parasitic cages\". The effect of multiple electric fields and at multiple frequencies had to be explored to eliminate the parasitic cages, and new theory was developed to describe the phenomenon in a straight forward and convenient way. The design process of dielectrophoretic structures known as flow through sorters was simplified significantly using a method that relies on non dimensional analysis and a figure of merit. These topics investigated have broader applications than just loading cells into vials. The dissertation demonstrates technologies and design and fabrication methods key to the cell loading design. The dissertation ends by describing the design of a device that can be implemented to load cells into vials on integrated circuit chips and outlining this device's expected characteristics and performance based on the theory and methods presented through the dissertation."],"dc:format.extent":["9180312 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7366"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["dielectrophoresis","cell manipulation","cell loading","multiple frequency dielectrophoresis","MFDEP","cell cage","cell clinics"],"dc:subject.proquest":["Engineering, Mechanical","Engineering, Biomedical","Engineering, General"],"dc:title":["Design of a dielectrophoretic cell loading device"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:43:36Z"}