{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7367"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7367","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws.","abstract":"Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct offers a healing advantage over another. An FEA analysis was conducted using ABAQUS, with all contact surfaces modeled as friction interfaces; additionally, a pretension was applied to the non-locking construct to simulate the effect of installation. The models were subjected to axial tension loads, and results were compared with existing cadaveric and synthetic experimental loading. Additional validation involved screw pullout testing conducted on cadaveric humeri. Results showed that the strain fields at the fracture site showed no significant variation in distribution, shape, or magnitude, therefore concluding that the locking plate offered no biomechanical healing advantage.","abstract_html":"Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct offers a healing advantage over another. An FEA analysis was conducted using ABAQUS, with all contact surfaces modeled as friction interfaces; additionally, a pretension was applied to the non-locking construct to simulate the effect of installation. The models were subjected to axial tension loads, and results were compared with existing cadaveric and synthetic experimental loading. Additional validation involved screw pullout testing conducted on cadaveric humeri. Results showed that the strain fields at the fracture site showed no significant variation in distribution, shape, or magnitude, therefore concluding that the locking plate offered no biomechanical healing advantage.","abstract_has_math":false,"creators":["Johnson, Aaron"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Barker, Donald"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-13","date_published":"2007-08-13","updated_at":"2026-11-19T08:44:55Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7367","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7367","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F7367","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7367","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Barker, Donald"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Johnson, Aaron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-09-28T15:02:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-09-28T15:02:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-08-13"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["humeral FEA comparison","locking and cortical screw pullout","humeral fixation","orthopedic","biomechanics"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical","Health Sciences, Medicine and Surgery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7367"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct offers a healing advantage over another. An FEA analysis was conducted using ABAQUS, with all contact surfaces modeled as friction interfaces; additionally, a pretension was applied to the non-locking construct to simulate the effect of installation. The models were subjected to axial tension loads, and results were compared with existing cadaveric and synthetic experimental loading. Additional validation involved screw pullout testing conducted on cadaveric humeri. Results showed that the strain fields at the fracture site showed no significant variation in distribution, shape, or magnitude, therefore concluding that the locking plate offered no biomechanical healing advantage."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["810982 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Barker, Donald"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Johnson, Aaron"],"dc:date.accessioned":["2007-09-28T15:02:17Z"],"dc:date.available":["2007-09-28T15:02:17Z"],"dc:date.issued":["2007-08-13"],"dc:description.abstract":["Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct offers a healing advantage over another. An FEA analysis was conducted using ABAQUS, with all contact surfaces modeled as friction interfaces; additionally, a pretension was applied to the non-locking construct to simulate the effect of installation. The models were subjected to axial tension loads, and results were compared with existing cadaveric and synthetic experimental loading. Additional validation involved screw pullout testing conducted on cadaveric humeri. Results showed that the strain fields at the fracture site showed no significant variation in distribution, shape, or magnitude, therefore concluding that the locking plate offered no biomechanical healing advantage."],"dc:format.extent":["810982 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7367"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["humeral FEA comparison","locking and cortical screw pullout","humeral fixation","orthopedic","biomechanics"],"dc:subject.proquest":["Engineering, Mechanical","Health Sciences, Medicine and Surgery"],"dc:title":["Humeral Fracture Fixation Techniques: A FEA comparison of locing and compression techniques with cadaveric pullout comparison of cortical compression and internal locking screws."],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:44:55Z"}