{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7369"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7369","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Ignition Testing of U.S. Army Rocket Launch Tubes with Comparative Heat Transfer Analysis","abstract":"The objective of this research was to determine the time to ignition of U.S. Army fiberglass epoxy rocket tubes in various conditions. Experiments were conducted using an oxygen calorimeter and a propane burner for determining the ignition time. The Biot number and heat transfer coefficient was determined. A lumped capacitance method was used to calculate the energy input. The energy input from the rocket plume into the tube was calculated using a semi-infinite solid with surface convection. The two energy calculations were compared indicating that approximately 1.4 rockets must be fired in rapid succession to lead to ignition conditions. Tube condition was found to have no affect on ignition time.","abstract_html":"The objective of this research was to determine the time to ignition of U.S. Army fiberglass epoxy rocket tubes in various conditions. Experiments were conducted using an oxygen calorimeter and a propane burner for determining the ignition time. The Biot number and heat transfer coefficient was determined. A lumped capacitance method was used to calculate the energy input. The energy input from the rocket plume into the tube was calculated using a semi-infinite solid with surface convection. The two energy calculations were compared indicating that approximately 1.4 rockets must be fired in rapid succession to lead to ignition conditions. Tube condition was found to have no affect on ignition time.","abstract_has_math":false,"creators":["Ozog, Nicholas E"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Fire Protection Engineering","school":null,"contributors":[],"advisors":["Milke, James A"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-07","date_published":"2007-08-07","updated_at":"2026-11-19T08:53:15Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7369","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7369","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F7369","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7369","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Milke, James A"]},{"key":"dc:contributor.department","label":"Department","values":["Fire Protection Engineering"]},{"key":"dc:creator","label":"Author","values":["Ozog, Nicholas E"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-09-28T15:02:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-09-28T15:02:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-08-07"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Ignition of Solid","Semi-Infinite Solid","Biot Number","Heat Transfer Coefficient","Oxygen Calorimeter","Propane Burner"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, General"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7369"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research was to determine the time to ignition of U.S. Army fiberglass epoxy rocket tubes in various conditions. Experiments were conducted using an oxygen calorimeter and a propane burner for determining the ignition time. The Biot number and heat transfer coefficient was determined. A lumped capacitance method was used to calculate the energy input. The energy input from the rocket plume into the tube was calculated using a semi-infinite solid with surface convection. The two energy calculations were compared indicating that approximately 1.4 rockets must be fired in rapid succession to lead to ignition conditions. Tube condition was found to have no affect on ignition time."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["5781696 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Ignition Testing of U.S. Army Rocket Launch Tubes with Comparative Heat Transfer Analysis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Milke, James A"],"dc:contributor.department":["Fire Protection Engineering"],"dc:creator":["Ozog, Nicholas E"],"dc:date.accessioned":["2007-09-28T15:02:20Z"],"dc:date.available":["2007-09-28T15:02:20Z"],"dc:date.issued":["2007-08-07"],"dc:description.abstract":["The objective of this research was to determine the time to ignition of U.S. Army fiberglass epoxy rocket tubes in various conditions. Experiments were conducted using an oxygen calorimeter and a propane burner for determining the ignition time. The Biot number and heat transfer coefficient was determined. A lumped capacitance method was used to calculate the energy input. The energy input from the rocket plume into the tube was calculated using a semi-infinite solid with surface convection. The two energy calculations were compared indicating that approximately 1.4 rockets must be fired in rapid succession to lead to ignition conditions. Tube condition was found to have no affect on ignition time."],"dc:format.extent":["5781696 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7369"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["Ignition of Solid","Semi-Infinite Solid","Biot Number","Heat Transfer Coefficient","Oxygen Calorimeter","Propane Burner"],"dc:subject.proquest":["Engineering, General"],"dc:title":["Ignition Testing of U.S. Army Rocket Launch Tubes with Comparative Heat Transfer Analysis"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:53:15Z"}