{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7402"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7402","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"MICROFLUIDICS INTERFACING TO MASS SPECTROMETRY","abstract":"Polymer-based microfluidic systems have received considerable attention for high throughput chemical analysis. Recently, the ongoing development of microfluidics interfacing to high-accuracy mass spectrometry to identify large molecules had an important impact on biochemistry. A primary goal of this dissertation is the development of a microfluidic apparatus for performing microscale gel electrophoresis, coupled with integrated electrospray tips for either direct interfacing to mass spectrometry through ESI-MS, or coupling to MALDI-MS through the deposition of separated analyte onto a MALDI target for offline analysis. In this dissertation, microfabrication techniques for polymer-based microchip are developed. A novel electrospray interface is demonstrated with good performance. The optimization of multi-channel electrospray tips for multiplexed analysis from a single microfluidic chip was demonstrated. Gas-phased electrophoretic protein/peptide concentration on a pre-structured MALDI target was further demonstrated via theoretical and experimental analysis. The results for developing μGE-ES using linear polymer gel validate the underlined principles and specify challenges involved in coupling μGE to MS. Finally, cross-linked polyacrylamide gel was explored and characterized using in-situ photo- polymerization method in microchannels.","abstract_html":"Polymer-based microfluidic systems have received considerable attention for high throughput chemical analysis. Recently, the ongoing development of microfluidics interfacing to high-accuracy mass spectrometry to identify large molecules had an important impact on biochemistry. A primary goal of this dissertation is the development of a microfluidic apparatus for performing microscale gel electrophoresis, coupled with integrated electrospray tips for either direct interfacing to mass spectrometry through ESI-MS, or coupling to MALDI-MS through the deposition of separated analyte onto a MALDI target for offline analysis. In this dissertation, microfabrication techniques for polymer-based microchip are developed. A novel electrospray interface is demonstrated with good performance. The optimization of multi-channel electrospray tips for multiplexed analysis from a single microfluidic chip was demonstrated. Gas-phased electrophoretic protein/peptide concentration on a pre-structured MALDI target was further demonstrated via theoretical and experimental analysis. The results for developing μGE-ES using linear polymer gel validate the underlined principles and specify challenges involved in coupling μGE to MS. Finally, cross-linked polyacrylamide gel was explored and characterized using in-situ photo- polymerization method in microchannels.","abstract_has_math":false,"creators":["Zhou, Yi"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Devoe, Don L"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-08-14","date_published":"2007-08-14","updated_at":"2026-11-19T08:54:25Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7402","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7402","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F7402","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7402","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Devoe, Don L"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Zhou, Yi"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-09-28T15:03:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-09-28T15:03:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-08-14"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7402"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Polymer-based microfluidic systems have received considerable attention for high throughput chemical analysis. Recently, the ongoing development of microfluidics interfacing to high-accuracy mass spectrometry to identify large molecules had an important impact on biochemistry. A primary goal of this dissertation is the development of a microfluidic apparatus for performing microscale gel electrophoresis, coupled with integrated electrospray tips for either direct interfacing to mass spectrometry through ESI-MS, or coupling to MALDI-MS through the deposition of separated analyte onto a MALDI target for offline analysis. In this dissertation, microfabrication techniques for polymer-based microchip are developed. A novel electrospray interface is demonstrated with good performance. The optimization of multi-channel electrospray tips for multiplexed analysis from a single microfluidic chip was demonstrated. Gas-phased electrophoretic protein/peptide concentration on a pre-structured MALDI target was further demonstrated via theoretical and experimental analysis. The results for developing μGE-ES using linear polymer gel validate the underlined principles and specify challenges involved in coupling μGE to MS. Finally, cross-linked polyacrylamide gel was explored and characterized using in-situ photo- polymerization method in microchannels."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["4254502 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["MICROFLUIDICS INTERFACING TO MASS SPECTROMETRY"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Devoe, Don L"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Zhou, Yi"],"dc:date.accessioned":["2007-09-28T15:03:25Z"],"dc:date.available":["2007-09-28T15:03:25Z"],"dc:date.issued":["2007-08-14"],"dc:description.abstract":["Polymer-based microfluidic systems have received considerable attention for high throughput chemical analysis. Recently, the ongoing development of microfluidics interfacing to high-accuracy mass spectrometry to identify large molecules had an important impact on biochemistry. A primary goal of this dissertation is the development of a microfluidic apparatus for performing microscale gel electrophoresis, coupled with integrated electrospray tips for either direct interfacing to mass spectrometry through ESI-MS, or coupling to MALDI-MS through the deposition of separated analyte onto a MALDI target for offline analysis. In this dissertation, microfabrication techniques for polymer-based microchip are developed. A novel electrospray interface is demonstrated with good performance. The optimization of multi-channel electrospray tips for multiplexed analysis from a single microfluidic chip was demonstrated. Gas-phased electrophoretic protein/peptide concentration on a pre-structured MALDI target was further demonstrated via theoretical and experimental analysis. The results for developing μGE-ES using linear polymer gel validate the underlined principles and specify challenges involved in coupling μGE to MS. Finally, cross-linked polyacrylamide gel was explored and characterized using in-situ photo- polymerization method in microchannels."],"dc:format.extent":["4254502 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7402"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.proquest":["Engineering, Mechanical"],"dc:title":["MICROFLUIDICS INTERFACING TO MASS SPECTROMETRY"],"dc:type":["Dissertation"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:54:25Z"}