{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/7655"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/7655","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Development of an Advanced Adhesion Test for Polymer Interfaces","abstract":"The bond strength of polymer interfaces within packaged microelectronic devices significantly influences their reliability. In the interest of predictive modeling and to facilitate materials selection during the design process, it is highly desirable to be able to distinguish between the adhesive performances of multiple polymer interfaces. However, typical adhesion testing is normally plagued by large deviations in its test results which make drawing statistical conclusions from adhesion strength data difficult. To remedy this, an investigation into the primary sources of variance associated with the pull test was performed. Four primary factors were identified, load alignment, loading rate, bond thickness, and the edge condition. The control of each of these four parameters was targeted during the development of an improved adhesion test technique. The results are an adhesion measurement method which has successfully reduced the scatter in test results from a standard deviation of 50% to approximately 10%.","abstract_html":"The bond strength of polymer interfaces within packaged microelectronic devices significantly influences their reliability. In the interest of predictive modeling and to facilitate materials selection during the design process, it is highly desirable to be able to distinguish between the adhesive performances of multiple polymer interfaces. However, typical adhesion testing is normally plagued by large deviations in its test results which make drawing statistical conclusions from adhesion strength data difficult. To remedy this, an investigation into the primary sources of variance associated with the pull test was performed. Four primary factors were identified, load alignment, loading rate, bond thickness, and the edge condition. The control of each of these four parameters was targeted during the development of an improved adhesion test technique. The results are an adhesion measurement method which has successfully reduced the scatter in test results from a standard deviation of 50% to approximately 10%.","abstract_has_math":false,"creators":["Vickey, Nathan Andrew"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Han, Bongtae"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-11-19","date_published":"2007-11-19","updated_at":"2026-11-19T08:55:06Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/7655","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/7655","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F7655","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Han, Bongtae"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Vickey, Nathan Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-04-22T16:03:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-04-22T16:03:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-11-19"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["adhesion testing","pull test","electronic packaging","polymer interfaces","variance"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical","Engineering, Packaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/7655"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The bond strength of polymer interfaces within packaged microelectronic devices significantly influences their reliability. In the interest of predictive modeling and to facilitate materials selection during the design process, it is highly desirable to be able to distinguish between the adhesive performances of multiple polymer interfaces. However, typical adhesion testing is normally plagued by large deviations in its test results which make drawing statistical conclusions from adhesion strength data difficult. To remedy this, an investigation into the primary sources of variance associated with the pull test was performed. Four primary factors were identified, load alignment, loading rate, bond thickness, and the edge condition. The control of each of these four parameters was targeted during the development of an improved adhesion test technique. The results are an adhesion measurement method which has successfully reduced the scatter in test results from a standard deviation of 50% to approximately 10%."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["2215631 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of an Advanced Adhesion Test for Polymer Interfaces"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Han, Bongtae"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Vickey, Nathan Andrew"],"dc:date.accessioned":["2008-04-22T16:03:37Z"],"dc:date.available":["2008-04-22T16:03:37Z"],"dc:date.issued":["2007-11-19"],"dc:description.abstract":["The bond strength of polymer interfaces within packaged microelectronic devices significantly influences their reliability. In the interest of predictive modeling and to facilitate materials selection during the design process, it is highly desirable to be able to distinguish between the adhesive performances of multiple polymer interfaces. However, typical adhesion testing is normally plagued by large deviations in its test results which make drawing statistical conclusions from adhesion strength data difficult. To remedy this, an investigation into the primary sources of variance associated with the pull test was performed. Four primary factors were identified, load alignment, loading rate, bond thickness, and the edge condition. The control of each of these four parameters was targeted during the development of an improved adhesion test technique. The results are an adhesion measurement method which has successfully reduced the scatter in test results from a standard deviation of 50% to approximately 10%."],"dc:format.extent":["2215631 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/7655"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["adhesion testing","pull test","electronic packaging","polymer interfaces","variance"],"dc:subject.proquest":["Engineering, Mechanical","Engineering, Packaging"],"dc:title":["Development of an Advanced Adhesion Test for Polymer Interfaces"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:55:06Z"}