{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/8927"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/8927","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"An Optical MEMS Sensor for On-chip Catechol Detection","abstract":"This thesis reports the successful design, fabrication and testing of an optical MEMS sensor for the detection of the toxic phenol, catechol. Catechol's presence in food and drinking water posses a health concern due to its harmful effects on cell respiration. By-products of catechol oxidation have demonstrated increased absorbance changes in a chitosan film in the UV and near UV range. Our reported sensor utilizes patterned SU-8 waveguides and a microfluidic channel to deliver catechol samples to an electrodeposited chitosan film for absorbance measurements at 472 nm. Concentrations as low as 1 mM catechol are detected while control experiments including ascorbic acid display no measurable response. By using optical detection methods, our device does not suffer from many of the problems which plague conventional electrochemical based sensors.","abstract_html":"This thesis reports the successful design, fabrication and testing of an optical MEMS sensor for the detection of the toxic phenol, catechol. Catechol&#x27;s presence in food and drinking water posses a health concern due to its harmful effects on cell respiration. By-products of catechol oxidation have demonstrated increased absorbance changes in a chitosan film in the UV and near UV range. Our reported sensor utilizes patterned SU-8 waveguides and a microfluidic channel to deliver catechol samples to an electrodeposited chitosan film for absorbance measurements at 472 nm. Concentrations as low as 1 mM catechol are detected while control experiments including ascorbic acid display no measurable response. By using optical detection methods, our device does not suffer from many of the problems which plague conventional electrochemical based sensors.","abstract_has_math":false,"creators":["Dykstra, Peter Hume"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Ghodssi, Reza"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-12-08","date_published":"2008-12-08","updated_at":"2026-11-19T08:53:17Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/8927","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/8927","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F8927","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F8927","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ghodssi, Reza"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Dykstra, Peter Hume"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-01-24T07:32:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-01-24T07:32:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-12-08"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Catechol","Chitosan","Microfluidic device","Polymer waveguides"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Electronics and Electrical","Engineering, Biomedical","Physics, Optics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/8927"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis reports the successful design, fabrication and testing of an optical MEMS sensor for the detection of the toxic phenol, catechol. Catechol's presence in food and drinking water posses a health concern due to its harmful effects on cell respiration. By-products of catechol oxidation have demonstrated increased absorbance changes in a chitosan film in the UV and near UV range. Our reported sensor utilizes patterned SU-8 waveguides and a microfluidic channel to deliver catechol samples to an electrodeposited chitosan film for absorbance measurements at 472 nm. Concentrations as low as 1 mM catechol are detected while control experiments including ascorbic acid display no measurable response. By using optical detection methods, our device does not suffer from many of the problems which plague conventional electrochemical based sensors."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["8217124 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An Optical MEMS Sensor for On-chip Catechol Detection"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ghodssi, Reza"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Dykstra, Peter Hume"],"dc:date.accessioned":["2009-01-24T07:32:41Z"],"dc:date.available":["2009-01-24T07:32:41Z"],"dc:date.issued":["2008-12-08"],"dc:description.abstract":["This thesis reports the successful design, fabrication and testing of an optical MEMS sensor for the detection of the toxic phenol, catechol. Catechol's presence in food and drinking water posses a health concern due to its harmful effects on cell respiration. By-products of catechol oxidation have demonstrated increased absorbance changes in a chitosan film in the UV and near UV range. Our reported sensor utilizes patterned SU-8 waveguides and a microfluidic channel to deliver catechol samples to an electrodeposited chitosan film for absorbance measurements at 472 nm. Concentrations as low as 1 mM catechol are detected while control experiments including ascorbic acid display no measurable response. By using optical detection methods, our device does not suffer from many of the problems which plague conventional electrochemical based sensors."],"dc:format.extent":["8217124 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/8927"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["Catechol","Chitosan","Microfluidic device","Polymer waveguides"],"dc:subject.proquest":["Engineering, Electronics and Electrical","Engineering, Biomedical","Physics, Optics"],"dc:title":["An Optical MEMS Sensor for On-chip Catechol Detection"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:53:17Z"}