{"id":{"repo_id":"maryland","oai_identifier":"oai:drum.lib.umd.edu:1903/9008"},"canonical_url":"https://search.ndltd.org/etd/maryland/oai:drum.lib.umd.edu:1903/9008","repository":{"repo_id":"maryland","name":"University of Maryland","base_url":"https://api.drum.lib.umd.edu/server/oai/request"},"display":{"title":"Performance and Oil Retention Characteristics of a CO2 Heat Pump Water Heater","abstract":"A CO2 heat pump water heater (HPWH) was investigated experimentally and analytically. In the first stage of the study, a baseline performance was measured, investigating the effect of operating parameters on the system performance under typical tank heating scenarios. In the second, the CO2 HPWH was modeled to investigate the effect of optimizing key components. In the third, the oil retention mass, the increase in pressure drop, and the COP degradation were measured as a function of oil mass fraction. In the fourth, two alternative system configurations were investigated for potential performance enhancement; a two-stage compression cycle with internal heat exchanger and a system with a suction line heat exchanger. Overall, the CO2 cycle seems uniquely suited for water heating. CO2 HPWHs have enormous energy savings potential if the cooling from the evaporator can be harnessed during the summer months, and rejected to the environment during the colder months.","abstract_html":"A CO2 heat pump water heater (HPWH) was investigated experimentally and analytically. In the first stage of the study, a baseline performance was measured, investigating the effect of operating parameters on the system performance under typical tank heating scenarios. In the second, the CO2 HPWH was modeled to investigate the effect of optimizing key components. In the third, the oil retention mass, the increase in pressure drop, and the COP degradation were measured as a function of oil mass fraction. In the fourth, two alternative system configurations were investigated for potential performance enhancement; a two-stage compression cycle with internal heat exchanger and a system with a suction line heat exchanger. Overall, the CO2 cycle seems uniquely suited for water heating. CO2 HPWHs have enormous energy savings potential if the cooling from the evaporator can be harnessed during the summer months, and rejected to the environment during the colder months.","abstract_has_math":false,"creators":["Fernandez, Nicholas Edward Peter"],"institution":"Digital Repository at the University of Maryland","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Radermacher, Reinhard K"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-19T08:43:13Z","subjects":[],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1903/9008","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1903/9008","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amaryland%3Aoai%3Adrum.lib.umd.edu%3A1903%2F9008","prefix":"oai_dc"},"source_record":{"url":"https://api.drum.lib.umd.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adrum.lib.umd.edu%3A1903%2F9008","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Radermacher, Reinhard K"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Fernandez, Nicholas Edward Peter"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-03-24T05:46:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-03-24T05:46:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["CO2","Heat pump water heater","internal heat exchanger","Oil Retention","suction line heat exchanger"]},{"key":"dc:subject.proquest","label":"Dc Subject Proquest","values":["Engineering, Mechanical","Engineering, Environmental","Energy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1903/9008"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A CO2 heat pump water heater (HPWH) was investigated experimentally and analytically. In the first stage of the study, a baseline performance was measured, investigating the effect of operating parameters on the system performance under typical tank heating scenarios. In the second, the CO2 HPWH was modeled to investigate the effect of optimizing key components. In the third, the oil retention mass, the increase in pressure drop, and the COP degradation were measured as a function of oil mass fraction. In the fourth, two alternative system configurations were investigated for potential performance enhancement; a two-stage compression cycle with internal heat exchanger and a system with a suction line heat exchanger. Overall, the CO2 cycle seems uniquely suited for water heating. CO2 HPWHs have enormous energy savings potential if the cooling from the evaporator can be harnessed during the summer months, and rejected to the environment during the colder months."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["3766404 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Performance and Oil Retention Characteristics of a CO2 Heat Pump Water Heater"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Radermacher, Reinhard K"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Fernandez, Nicholas Edward Peter"],"dc:date.accessioned":["2009-03-24T05:46:31Z"],"dc:date.available":["2009-03-24T05:46:31Z"],"dc:date.issued":["2008"],"dc:description.abstract":["A CO2 heat pump water heater (HPWH) was investigated experimentally and analytically. In the first stage of the study, a baseline performance was measured, investigating the effect of operating parameters on the system performance under typical tank heating scenarios. In the second, the CO2 HPWH was modeled to investigate the effect of optimizing key components. In the third, the oil retention mass, the increase in pressure drop, and the COP degradation were measured as a function of oil mass fraction. In the fourth, two alternative system configurations were investigated for potential performance enhancement; a two-stage compression cycle with internal heat exchanger and a system with a suction line heat exchanger. Overall, the CO2 cycle seems uniquely suited for water heating. CO2 HPWHs have enormous energy savings potential if the cooling from the evaporator can be harnessed during the summer months, and rejected to the environment during the colder months."],"dc:format.extent":["3766404 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/1903/9008"],"dc:language.iso":["en_US"],"dc:publisher":["Digital Repository at the University of Maryland","University of Maryland (College Park, Md.)"],"dc:subject.keyword":["CO2","Heat pump water heater","internal heat exchanger","Oil Retention","suction line heat exchanger"],"dc:subject.proquest":["Engineering, Mechanical","Engineering, Environmental","Energy"],"dc:title":["Performance and Oil Retention Characteristics of a CO2 Heat Pump Water Heater"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T08:43:13Z"}