{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/11345"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/11345","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Experimental Evaluation of Bone Drilling using Ultrashort Pulsed Laser Ablation","abstract":"<p>Mechanical oscillating drills and saws are used in orthopaedic surgery to cut bone and develop screw-holes; however, their use causes friction resulting in significant thermal damage. Ultrashort pulsed lasers appear well-suited to replace traditional tools as they have the ability to efficiently remove bone tissue while causing only minimal collateral damage. Laser ablation also has the added advantages of: (i) no mechanical vibration; (ii) minimal invasiveness; and (iii) small focus spot size. In this thesis work, we experimentally investigated a few key aspects of ultrashort laser ablation of bone tissue.</p> <p>The ablation threshold of unaltered bone was measured using the <em>D</em><sup>2 </sup>technique and found to range from 1.66 J/cm<sup>2 </sup>± 0.87 J/cm<sup>2</sup> to 2.37 J/cm<sup>2 </sup>± 0.78 J/cm<sup>2</sup> depending on incident pulse number. The reduction in ablation threshold with pulse number was an indication of an incubation effect. Using a power law model, the incubation coefficient, ζ, was measured to be 0.89 ± 0.03.</p> <p>The effect of specific laser parameters and drilling protocols on ablation efficiency was also characterized. For ultrashort pulses (≤10 ps), the removal rate was found to be inversely related to the pulse duration; however, irradiation with 5-10 ps pulses were also shown to result in significant tissue removal. With a pulse repetition rate of 1 kHz, the removal rate was observed to be highest when ablating with 50-100 pulses per spot.</p> <p>Larger volumes (>1 mm<sup>3</sup>) of bone tissue were removed using laser scanning procedures. A series of scanned concentric circles produced a structure ~2.4 mm deep; however, ablated side-lobes were present at oblique angles to the incident beam. A two-layer structure subsequently produced no side-lobes. The ablative precision in trabecular bone was observed to be less than cortical bone. Using mimicked Nd:YAG laser parameters, cylindrical drilling produced craters significantly less deep than those achieved with a typical Ti:Sapphire configuration. The ability to drill large-scale holes using low average pulse energies and optimized scanning procedures will alleviate the stringent requirements for optical components in clinical practice.</p>","abstract_html":"&lt;p&gt;Mechanical oscillating drills and saws are used in orthopaedic surgery to cut bone and develop screw-holes; however, their use causes friction resulting in significant thermal damage. Ultrashort pulsed lasers appear well-suited to replace traditional tools as they have the ability to efficiently remove bone tissue while causing only minimal collateral damage. Laser ablation also has the added advantages of: (i) no mechanical vibration; (ii) minimal invasiveness; and (iii) small focus spot size. In this thesis work, we experimentally investigated a few key aspects of ultrashort laser ablation of bone tissue.&lt;/p&gt; &lt;p&gt;The ablation threshold of unaltered bone was measured using the &lt;em&gt;D&lt;/em&gt;&lt;sup&gt;2 &lt;/sup&gt;technique and found to range from 1.66 J/cm&lt;sup&gt;2 &lt;/sup&gt;± 0.87 J/cm&lt;sup&gt;2&lt;/sup&gt; to 2.37 J/cm&lt;sup&gt;2 &lt;/sup&gt;± 0.78 J/cm&lt;sup&gt;2&lt;/sup&gt; depending on incident pulse number. The reduction in ablation threshold with pulse number was an indication of an incubation effect. Using a power law model, the incubation coefficient, ζ, was measured to be 0.89 ± 0.03.&lt;/p&gt; &lt;p&gt;The effect of specific laser parameters and drilling protocols on ablation efficiency was also characterized. For ultrashort pulses (≤10 ps), the removal rate was found to be inversely related to the pulse duration; however, irradiation with 5-10 ps pulses were also shown to result in significant tissue removal. With a pulse repetition rate of 1 kHz, the removal rate was observed to be highest when ablating with 50-100 pulses per spot.&lt;/p&gt; &lt;p&gt;Larger volumes (&gt;1 mm&lt;sup&gt;3&lt;/sup&gt;) of bone tissue were removed using laser scanning procedures. A series of scanned concentric circles produced a structure ~2.4 mm deep; however, ablated side-lobes were present at oblique angles to the incident beam. A two-layer structure subsequently produced no side-lobes. The ablative precision in trabecular bone was observed to be less than cortical bone. Using mimicked Nd:YAG laser parameters, cylindrical drilling produced craters significantly less deep than those achieved with a typical Ti:Sapphire configuration. The ability to drill large-scale holes using low average pulse energies and optimized scanning procedures will alleviate the stringent requirements for optical components in clinical practice.&lt;/p&gt;","abstract_has_math":false,"creators":["Emigh, Brent J."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Medical Physics","school":null,"contributors":[],"advisors":["Fang, Qiyin","Hayward, Joseph E.","Haugen, Harold K."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-10","date_published":"2011-10","updated_at":"2026-11-18T19:38:38Z","subjects":["Laser ablation","femtosecond","bone","ultrafast material processing","incubation","Bioimaging and biomedical optics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/21576"],"render_values":[{"text":"https://doi.org/10.71548/21576","href":"https://doi.org/10.71548/21576","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/6319","7371","2262372"],"render_values":[{"text":"opendissertations/6319","href":null,"code":true},{"text":"7371","href":null,"code":true},{"text":"2262372","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/11345","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/11345","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F11345","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fang, Qiyin","Hayward, Joseph E.","Haugen, Harold K."]},{"key":"dc:contributor.department","label":"Department","values":["Medical Physics"]},{"key":"dc:creator","label":"Author","values":["Emigh, Brent J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:54:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:54:21Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-09-28"]},{"key":"dc:date.issued","label":"Date","values":["2011-10"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Laser ablation","femtosecond","bone","ultrafast material processing","incubation","Bioimaging and biomedical optics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/6319","7371","2262372"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/11345","https://doi.org/10.71548/21576"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Mechanical oscillating drills and saws are used in orthopaedic surgery to cut bone and develop screw-holes; however, their use causes friction resulting in significant thermal damage. Ultrashort pulsed lasers appear well-suited to replace traditional tools as they have the ability to efficiently remove bone tissue while causing only minimal collateral damage. Laser ablation also has the added advantages of: (i) no mechanical vibration; (ii) minimal invasiveness; and (iii) small focus spot size. In this thesis work, we experimentally investigated a few key aspects of ultrashort laser ablation of bone tissue.</p> <p>The ablation threshold of unaltered bone was measured using the <em>D</em><sup>2 </sup>technique and found to range from 1.66 J/cm<sup>2 </sup>± 0.87 J/cm<sup>2</sup> to 2.37 J/cm<sup>2 </sup>± 0.78 J/cm<sup>2</sup> depending on incident pulse number. The reduction in ablation threshold with pulse number was an indication of an incubation effect. Using a power law model, the incubation coefficient, ζ, was measured to be 0.89 ± 0.03.</p> <p>The effect of specific laser parameters and drilling protocols on ablation efficiency was also characterized. For ultrashort pulses (≤10 ps), the removal rate was found to be inversely related to the pulse duration; however, irradiation with 5-10 ps pulses were also shown to result in significant tissue removal. With a pulse repetition rate of 1 kHz, the removal rate was observed to be highest when ablating with 50-100 pulses per spot.</p> <p>Larger volumes (>1 mm<sup>3</sup>) of bone tissue were removed using laser scanning procedures. A series of scanned concentric circles produced a structure ~2.4 mm deep; however, ablated side-lobes were present at oblique angles to the incident beam. A two-layer structure subsequently produced no side-lobes. The ablative precision in trabecular bone was observed to be less than cortical bone. Using mimicked Nd:YAG laser parameters, cylindrical drilling produced craters significantly less deep than those achieved with a typical Ti:Sapphire configuration. The ability to drill large-scale holes using low average pulse energies and optimized scanning procedures will alleviate the stringent requirements for optical components in clinical practice.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (MSc)"]},{"key":"dc:title","label":"Title","values":["Experimental Evaluation of Bone Drilling using Ultrashort Pulsed Laser Ablation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fang, Qiyin","Hayward, Joseph E.","Haugen, Harold K."],"dc:contributor.department":["Medical Physics"],"dc:creator":["Emigh, Brent J."],"dc:date.accessioned":["2014-06-18T16:54:21Z"],"dc:date.available":["2014-06-18T16:54:21Z"],"dc:date.created":["2011-09-28"],"dc:date.issued":["2011-10"],"dc:description.abstract":["<p>Mechanical oscillating drills and saws are used in orthopaedic surgery to cut bone and develop screw-holes; however, their use causes friction resulting in significant thermal damage. Ultrashort pulsed lasers appear well-suited to replace traditional tools as they have the ability to efficiently remove bone tissue while causing only minimal collateral damage. Laser ablation also has the added advantages of: (i) no mechanical vibration; (ii) minimal invasiveness; and (iii) small focus spot size. In this thesis work, we experimentally investigated a few key aspects of ultrashort laser ablation of bone tissue.</p> <p>The ablation threshold of unaltered bone was measured using the <em>D</em><sup>2 </sup>technique and found to range from 1.66 J/cm<sup>2 </sup>± 0.87 J/cm<sup>2</sup> to 2.37 J/cm<sup>2 </sup>± 0.78 J/cm<sup>2</sup> depending on incident pulse number. The reduction in ablation threshold with pulse number was an indication of an incubation effect. Using a power law model, the incubation coefficient, ζ, was measured to be 0.89 ± 0.03.</p> <p>The effect of specific laser parameters and drilling protocols on ablation efficiency was also characterized. For ultrashort pulses (≤10 ps), the removal rate was found to be inversely related to the pulse duration; however, irradiation with 5-10 ps pulses were also shown to result in significant tissue removal. With a pulse repetition rate of 1 kHz, the removal rate was observed to be highest when ablating with 50-100 pulses per spot.</p> <p>Larger volumes (>1 mm<sup>3</sup>) of bone tissue were removed using laser scanning procedures. A series of scanned concentric circles produced a structure ~2.4 mm deep; however, ablated side-lobes were present at oblique angles to the incident beam. A two-layer structure subsequently produced no side-lobes. The ablative precision in trabecular bone was observed to be less than cortical bone. Using mimicked Nd:YAG laser parameters, cylindrical drilling produced craters significantly less deep than those achieved with a typical Ti:Sapphire configuration. The ability to drill large-scale holes using low average pulse energies and optimized scanning procedures will alleviate the stringent requirements for optical components in clinical practice.</p>"],"dc:description.degree":["Master of Science (MSc)"],"dc:identifier.other":["opendissertations/6319","7371","2262372"],"dc:identifier.uri":["http://hdl.handle.net/11375/11345","https://doi.org/10.71548/21576"],"dc:subject":["Laser ablation","femtosecond","bone","ultrafast material processing","incubation","Bioimaging and biomedical optics"],"dc:title":["Experimental Evaluation of Bone Drilling using Ultrashort Pulsed Laser Ablation"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:38Z"}