{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/13671"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/13671","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Design and Construction of an Avalanche Photodioclc-Based Gamma CRmera Prototype","abstract":"<p>Objective: The design of a prototype avalanche photodiode gamma camera and an adaptable and expandable acquisition board. To test the performance of the acquisition board a photomultiplier base camera is constructed and utilized in various configurations. The APD-based gamma camera is tested on the same acquisition board to evaluate its performance.</p> <p>Results:Spectra have been collected and analyzed utilizing four various detector/system configurations. i) a PET module, utilizing a PMT coupled to a pixilated BGO crystal with a high energy Na-22 source. ii) a single PMT extracted from a PET module akin to the one mentioned previously and coupled to NaI(T1) with a Co-57 source. iii) the same PMT coupled to a CsI(T1) crystal with a variety of sources, including Tc-99m, Ga-67 and Co37. iv) an APD coupled to a CsI(T1) crystal with a variety of sources including Tc-99m and Co-57. Images have been collected from multiple camera configurations, all by a 2 by 2 array. APD's with CsI(T!), PMT's and NaI(T1) and a PET module with PMT's on BGO</p> <p>Conclusion: These requirements have been met with the current design and the system has been tested in a controlled environment. collecting spectrum while operating a single channel and for some configurations, images were collected operating a multi-channel array. A number of steps can be taken to improve upon this prototype, The detector itself may benefit from a pixilated crystal and current APD technology. The acquisition board should be transferred to a multiple printed circuit board design allowing it to be implemented ill a black-box manner. Additionally. the current USB bridge' limits the transfer rate of data between the DSC and the' PC. as a result. alternatives should be investigated.</p>","abstract_html":"&lt;p&gt;Objective: The design of a prototype avalanche photodiode gamma camera and an adaptable and expandable acquisition board. To test the performance of the acquisition board a photomultiplier base camera is constructed and utilized in various configurations. The APD-based gamma camera is tested on the same acquisition board to evaluate its performance.&lt;/p&gt; &lt;p&gt;Results:Spectra have been collected and analyzed utilizing four various detector/system configurations. i) a PET module, utilizing a PMT coupled to a pixilated BGO crystal with a high energy Na-22 source. ii) a single PMT extracted from a PET module akin to the one mentioned previously and coupled to NaI(T1) with a Co-57 source. iii) the same PMT coupled to a CsI(T1) crystal with a variety of sources, including Tc-99m, Ga-67 and Co37. iv) an APD coupled to a CsI(T1) crystal with a variety of sources including Tc-99m and Co-57. Images have been collected from multiple camera configurations, all by a 2 by 2 array. APD&#x27;s with CsI(T!), PMT&#x27;s and NaI(T1) and a PET module with PMT&#x27;s on BGO&lt;/p&gt; &lt;p&gt;Conclusion: These requirements have been met with the current design and the system has been tested in a controlled environment. collecting spectrum while operating a single channel and for some configurations, images were collected operating a multi-channel array. A number of steps can be taken to improve upon this prototype, The detector itself may benefit from a pixilated crystal and current APD technology. The acquisition board should be transferred to a multiple printed circuit board design allowing it to be implemented ill a black-box manner. Additionally. the current USB bridge&#x27; limits the transfer rate of data between the DSC and the&#x27; PC. as a result. alternatives should be investigated.&lt;/p&gt;","abstract_has_math":false,"creators":["Smith, Jamie"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Medical Physics","school":null,"contributors":[],"advisors":["Farncombe, Troy H."],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007-11","date_published":"2007-11","updated_at":"2026-11-18T19:38:18Z","subjects":["Other Medical Sciences","Other Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/20631"],"render_values":[{"text":"https://doi.org/10.71548/20631","href":"https://doi.org/10.71548/20631","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/8506","9584","4822925"],"render_values":[{"text":"opendissertations/8506","href":null,"code":true},{"text":"9584","href":null,"code":true},{"text":"4822925","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/13671","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/13671","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F13671","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Farncombe, Troy H."]},{"key":"dc:contributor.department","label":"Department","values":["Medical Physics"]},{"key":"dc:creator","label":"Author","values":["Smith, Jamie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T17:04:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T17:04:48Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2013-11-14"]},{"key":"dc:date.issued","label":"Date","values":["2007-11"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Other Medical Sciences","Other Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/8506","9584","4822925"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/13671","https://doi.org/10.71548/20631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Objective: The design of a prototype avalanche photodiode gamma camera and an adaptable and expandable acquisition board. To test the performance of the acquisition board a photomultiplier base camera is constructed and utilized in various configurations. The APD-based gamma camera is tested on the same acquisition board to evaluate its performance.</p> <p>Results:Spectra have been collected and analyzed utilizing four various detector/system configurations. i) a PET module, utilizing a PMT coupled to a pixilated BGO crystal with a high energy Na-22 source. ii) a single PMT extracted from a PET module akin to the one mentioned previously and coupled to NaI(T1) with a Co-57 source. iii) the same PMT coupled to a CsI(T1) crystal with a variety of sources, including Tc-99m, Ga-67 and Co37. iv) an APD coupled to a CsI(T1) crystal with a variety of sources including Tc-99m and Co-57. Images have been collected from multiple camera configurations, all by a 2 by 2 array. APD's with CsI(T!), PMT's and NaI(T1) and a PET module with PMT's on BGO</p> <p>Conclusion: These requirements have been met with the current design and the system has been tested in a controlled environment. collecting spectrum while operating a single channel and for some configurations, images were collected operating a multi-channel array. A number of steps can be taken to improve upon this prototype, The detector itself may benefit from a pixilated crystal and current APD technology. The acquisition board should be transferred to a multiple printed circuit board design allowing it to be implemented ill a black-box manner. Additionally. the current USB bridge' limits the transfer rate of data between the DSC and the' PC. as a result. alternatives should be investigated.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (MSc)"]},{"key":"dc:title","label":"Title","values":["Design and Construction of an Avalanche Photodioclc-Based Gamma CRmera Prototype"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Farncombe, Troy H."],"dc:contributor.department":["Medical Physics"],"dc:creator":["Smith, Jamie"],"dc:date.accessioned":["2014-06-18T17:04:48Z"],"dc:date.available":["2014-06-18T17:04:48Z"],"dc:date.created":["2013-11-14"],"dc:date.issued":["2007-11"],"dc:description.abstract":["<p>Objective: The design of a prototype avalanche photodiode gamma camera and an adaptable and expandable acquisition board. To test the performance of the acquisition board a photomultiplier base camera is constructed and utilized in various configurations. The APD-based gamma camera is tested on the same acquisition board to evaluate its performance.</p> <p>Results:Spectra have been collected and analyzed utilizing four various detector/system configurations. i) a PET module, utilizing a PMT coupled to a pixilated BGO crystal with a high energy Na-22 source. ii) a single PMT extracted from a PET module akin to the one mentioned previously and coupled to NaI(T1) with a Co-57 source. iii) the same PMT coupled to a CsI(T1) crystal with a variety of sources, including Tc-99m, Ga-67 and Co37. iv) an APD coupled to a CsI(T1) crystal with a variety of sources including Tc-99m and Co-57. Images have been collected from multiple camera configurations, all by a 2 by 2 array. APD's with CsI(T!), PMT's and NaI(T1) and a PET module with PMT's on BGO</p> <p>Conclusion: These requirements have been met with the current design and the system has been tested in a controlled environment. collecting spectrum while operating a single channel and for some configurations, images were collected operating a multi-channel array. A number of steps can be taken to improve upon this prototype, The detector itself may benefit from a pixilated crystal and current APD technology. The acquisition board should be transferred to a multiple printed circuit board design allowing it to be implemented ill a black-box manner. Additionally. the current USB bridge' limits the transfer rate of data between the DSC and the' PC. as a result. alternatives should be investigated.</p>"],"dc:description.degree":["Master of Science (MSc)"],"dc:identifier.other":["opendissertations/8506","9584","4822925"],"dc:identifier.uri":["http://hdl.handle.net/11375/13671","https://doi.org/10.71548/20631"],"dc:subject":["Other Medical Sciences","Other Physics"],"dc:title":["Design and Construction of an Avalanche Photodioclc-Based Gamma CRmera Prototype"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:18Z"}