{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/15339"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/15339","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"MICROFLUIDIC DEVICE FOR MICROINJECTION OF CAENORHABDITIS ELEGANS","abstract":"<p>Microinjection is an established and reliable method to deliver transgenic constructs and other reagents to specific locations in the animal. Specifically, microinjection of a desired DNA construct into the distal gonad is the most widely used method to generate germ-line transformation of <em>C. elegans</em>. Although, current <em>C. elegans</em> microinjection method is an effective manner for creating transgenic worms, it requirements such as expensive multi DOF micromanipulator, detailed injection alignment procedure and skilled operator which makes the microinjection process slow and not suitable for scale to high throughput. Although many microfabricated microinjectors exist, none of them are capable of immobilizing a freely mobile animal such as <em>C.elegans</em> worm. In this research, a microfluidic microinjector was developed to simultaneously immobilize a freely mobile animal such as <em>C.elegans</em> and perform microinjection by using a simple and fast mechanism for needle actuation. The entire process of the microinjection takes ~30 seconds which includes 10s for worm loading and aligning, 5s needle penetration, 5s reagent injection and 5s worm unloading. The capability of the microinjector chip for creating transgenic <em>C. elegans</em> was illustrated (with success rate between 4% to 20%)</p>","abstract_html":"&lt;p&gt;Microinjection is an established and reliable method to deliver transgenic constructs and other reagents to specific locations in the animal. Specifically, microinjection of a desired DNA construct into the distal gonad is the most widely used method to generate germ-line transformation of &lt;em&gt;C. elegans&lt;/em&gt;. Although, current &lt;em&gt;C. elegans&lt;/em&gt; microinjection method is an effective manner for creating transgenic worms, it requirements such as expensive multi DOF micromanipulator, detailed injection alignment procedure and skilled operator which makes the microinjection process slow and not suitable for scale to high throughput. Although many microfabricated microinjectors exist, none of them are capable of immobilizing a freely mobile animal such as &lt;em&gt;C.elegans&lt;/em&gt; worm. In this research, a microfluidic microinjector was developed to simultaneously immobilize a freely mobile animal such as &lt;em&gt;C.elegans&lt;/em&gt; and perform microinjection by using a simple and fast mechanism for needle actuation. The entire process of the microinjection takes ~30 seconds which includes 10s for worm loading and aligning, 5s needle penetration, 5s reagent injection and 5s worm unloading. The capability of the microinjector chip for creating transgenic &lt;em&gt;C. elegans&lt;/em&gt; was illustrated (with success rate between 4% to 20%)&lt;/p&gt;","abstract_has_math":false,"creators":["Ghaemi, Reza"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Selvaganapathy, P. R.","Gupta, Bhagwati"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-04","date_published":"2014-04","updated_at":"2026-11-19T05:55:01Z","subjects":["Microfluidic","Microinjection","C. elegans","Transgenic","Behavioral Neurobiology","Biological Engineering","Biology","Biomechanical Engineering","Biomedical devices and instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/18070"],"render_values":[{"text":"https://doi.org/10.71548/18070","href":"https://doi.org/10.71548/18070","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/8812","9890","5231581"],"render_values":[{"text":"opendissertations/8812","href":null,"code":true},{"text":"9890","href":null,"code":true},{"text":"5231581","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/15339","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/15339","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2015-02-27","access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F15339","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Selvaganapathy, P. R.","Gupta, Bhagwati"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Ghaemi, Reza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T21:13:42Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2014-02-27"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2015-02-27"]},{"key":"dc:date.issued","label":"Date","values":["2014-04"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidic","Microinjection","C. elegans","Transgenic","Behavioral Neurobiology","Biological Engineering","Biology","Biomechanical Engineering","Biomedical devices and instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/8812","9890","5231581"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/15339","https://doi.org/10.71548/18070"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Microinjection is an established and reliable method to deliver transgenic constructs and other reagents to specific locations in the animal. Specifically, microinjection of a desired DNA construct into the distal gonad is the most widely used method to generate germ-line transformation of <em>C. elegans</em>. Although, current <em>C. elegans</em> microinjection method is an effective manner for creating transgenic worms, it requirements such as expensive multi DOF micromanipulator, detailed injection alignment procedure and skilled operator which makes the microinjection process slow and not suitable for scale to high throughput. Although many microfabricated microinjectors exist, none of them are capable of immobilizing a freely mobile animal such as <em>C.elegans</em> worm. In this research, a microfluidic microinjector was developed to simultaneously immobilize a freely mobile animal such as <em>C.elegans</em> and perform microinjection by using a simple and fast mechanism for needle actuation. The entire process of the microinjection takes ~30 seconds which includes 10s for worm loading and aligning, 5s needle penetration, 5s reagent injection and 5s worm unloading. The capability of the microinjector chip for creating transgenic <em>C. elegans</em> was illustrated (with success rate between 4% to 20%)</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (MSc)"]},{"key":"dc:title","label":"Title","values":["MICROFLUIDIC DEVICE FOR MICROINJECTION OF CAENORHABDITIS ELEGANS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Selvaganapathy, P. R.","Gupta, Bhagwati"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Ghaemi, Reza"],"dc:date.accessioned":["2014-06-18T21:13:42Z"],"dc:date.created":["2014-02-27"],"dc:date.embargo":["2015-02-27"],"dc:date.issued":["2014-04"],"dc:description.abstract":["<p>Microinjection is an established and reliable method to deliver transgenic constructs and other reagents to specific locations in the animal. Specifically, microinjection of a desired DNA construct into the distal gonad is the most widely used method to generate germ-line transformation of <em>C. elegans</em>. Although, current <em>C. elegans</em> microinjection method is an effective manner for creating transgenic worms, it requirements such as expensive multi DOF micromanipulator, detailed injection alignment procedure and skilled operator which makes the microinjection process slow and not suitable for scale to high throughput. Although many microfabricated microinjectors exist, none of them are capable of immobilizing a freely mobile animal such as <em>C.elegans</em> worm. In this research, a microfluidic microinjector was developed to simultaneously immobilize a freely mobile animal such as <em>C.elegans</em> and perform microinjection by using a simple and fast mechanism for needle actuation. The entire process of the microinjection takes ~30 seconds which includes 10s for worm loading and aligning, 5s needle penetration, 5s reagent injection and 5s worm unloading. The capability of the microinjector chip for creating transgenic <em>C. elegans</em> was illustrated (with success rate between 4% to 20%)</p>"],"dc:description.degree":["Master of Science (MSc)"],"dc:identifier.other":["opendissertations/8812","9890","5231581"],"dc:identifier.uri":["http://hdl.handle.net/11375/15339","https://doi.org/10.71548/18070"],"dc:subject":["Microfluidic","Microinjection","C. elegans","Transgenic","Behavioral Neurobiology","Biological Engineering","Biology","Biomechanical Engineering","Biomedical devices and instrumentation"],"dc:title":["MICROFLUIDIC DEVICE FOR MICROINJECTION OF CAENORHABDITIS ELEGANS"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T05:55:01Z"}