{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/17202"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/17202","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Load-following heat, hot water and power distributed generation using an integrated solid oxide fuel cell, compressed air energy storage and solar panel array system.","abstract":"Distributed generation (defined as the production of power in small quantities at the point of use) has recently gained significant interest due to its benefits over a centralized approach. This thesis investigates the integration of a natural gas fed solid-oxide fuel cell (SOFC) and compressed air energy storage (CAES) technologies for distributed generation at the building-level scale. The SOFC/CAES system is also integrated with multiple vital sub-systems (including on-site solar panels) for the building to provide the heat, through an in-floor heating system, hot water, and power demanded by the building. This thesis investigates the models for the SOFC/CAES system, and implements them in a generic analysis tool providing a means for rapid analysis of a wide variety of case studies. The analysis tool determines the ability of the SOFC/CAES system to follow the power and heat loads demanded by the building, and evaluates its performance with an assortment of metrics, including efficiencies, CO2 emissions and grid-independence. The SOFC/CAES system was investigated for the new ExCEL building at McMaster University. It was found that the system was able to produce upwards 75% of the heat and hot water demand, and upwards of 94% of the power demand of the building. When compared to the current state-of-the-art natural gas based power producing technology and high efficiency furnace, the SOFC/CAES system reduces the CO2 emissions associated with the building by a minimum of 8.7% and a maximum of 26.95%. The cost of electricity for the system is significantly (21% to 150%) more costly than current market prices; however the SOFC/CAES system is the least costly of all other distributed generation technologies investigated for the case of the ExCEL building.","abstract_html":"Distributed generation (defined as the production of power in small quantities at the point of use) has recently gained significant interest due to its benefits over a centralized approach. This thesis investigates the integration of a natural gas fed solid-oxide fuel cell (SOFC) and compressed air energy storage (CAES) technologies for distributed generation at the building-level scale. The SOFC/CAES system is also integrated with multiple vital sub-systems (including on-site solar panels) for the building to provide the heat, through an in-floor heating system, hot water, and power demanded by the building. This thesis investigates the models for the SOFC/CAES system, and implements them in a generic analysis tool providing a means for rapid analysis of a wide variety of case studies. The analysis tool determines the ability of the SOFC/CAES system to follow the power and heat loads demanded by the building, and evaluates its performance with an assortment of metrics, including efficiencies, CO2 emissions and grid-independence. The SOFC/CAES system was investigated for the new ExCEL building at McMaster University. It was found that the system was able to produce upwards 75% of the heat and hot water demand, and upwards of 94% of the power demand of the building. When compared to the current state-of-the-art natural gas based power producing technology and high efficiency furnace, the SOFC/CAES system reduces the CO2 emissions associated with the building by a minimum of 8.7% and a maximum of 26.95%. The cost of electricity for the system is significantly (21% to 150%) more costly than current market prices; however the SOFC/CAES system is the least costly of all other distributed generation technologies investigated for the case of the ExCEL building.","abstract_has_math":false,"creators":["Lefebvre, Kyle"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["Adams II, Thomas"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06","date_published":"2015-06","updated_at":"2026-11-18T19:38:05Z","subjects":["SOFC","Distributed Generation","CAES"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/19966"],"render_values":[{"text":"https://doi.org/10.71548/19966","href":"https://doi.org/10.71548/19966","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/17202","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/17202","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F17202","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Adams II, Thomas"]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Lefebvre, Kyle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-04-23T18:27:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-04-23T18:27:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-06"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["SOFC","Distributed Generation","CAES"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/17202","https://doi.org/10.71548/19966"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Distributed generation (defined as the production of power in small quantities at the point of use) has recently gained significant interest due to its benefits over a centralized approach. This thesis investigates the integration of a natural gas fed solid-oxide fuel cell (SOFC) and compressed air energy storage (CAES) technologies for distributed generation at the building-level scale. The SOFC/CAES system is also integrated with multiple vital sub-systems (including on-site solar panels) for the building to provide the heat, through an in-floor heating system, hot water, and power demanded by the building. This thesis investigates the models for the SOFC/CAES system, and implements them in a generic analysis tool providing a means for rapid analysis of a wide variety of case studies. The analysis tool determines the ability of the SOFC/CAES system to follow the power and heat loads demanded by the building, and evaluates its performance with an assortment of metrics, including efficiencies, CO2 emissions and grid-independence. The SOFC/CAES system was investigated for the new ExCEL building at McMaster University. It was found that the system was able to produce upwards 75% of the heat and hot water demand, and upwards of 94% of the power demand of the building. When compared to the current state-of-the-art natural gas based power producing technology and high efficiency furnace, the SOFC/CAES system reduces the CO2 emissions associated with the building by a minimum of 8.7% and a maximum of 26.95%. The cost of electricity for the system is significantly (21% to 150%) more costly than current market prices; however the SOFC/CAES system is the least costly of all other distributed generation technologies investigated for the case of the ExCEL building."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["Load-following heat, hot water and power distributed generation using an integrated solid oxide fuel cell, compressed air energy storage and solar panel array system."]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Adams II, Thomas"],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Lefebvre, Kyle"],"dc:date.accessioned":["2015-04-23T18:27:01Z"],"dc:date.available":["2015-04-23T18:27:01Z"],"dc:date.issued":["2015-06"],"dc:description.abstract":["Distributed generation (defined as the production of power in small quantities at the point of use) has recently gained significant interest due to its benefits over a centralized approach. This thesis investigates the integration of a natural gas fed solid-oxide fuel cell (SOFC) and compressed air energy storage (CAES) technologies for distributed generation at the building-level scale. The SOFC/CAES system is also integrated with multiple vital sub-systems (including on-site solar panels) for the building to provide the heat, through an in-floor heating system, hot water, and power demanded by the building. This thesis investigates the models for the SOFC/CAES system, and implements them in a generic analysis tool providing a means for rapid analysis of a wide variety of case studies. The analysis tool determines the ability of the SOFC/CAES system to follow the power and heat loads demanded by the building, and evaluates its performance with an assortment of metrics, including efficiencies, CO2 emissions and grid-independence. The SOFC/CAES system was investigated for the new ExCEL building at McMaster University. It was found that the system was able to produce upwards 75% of the heat and hot water demand, and upwards of 94% of the power demand of the building. When compared to the current state-of-the-art natural gas based power producing technology and high efficiency furnace, the SOFC/CAES system reduces the CO2 emissions associated with the building by a minimum of 8.7% and a maximum of 26.95%. The cost of electricity for the system is significantly (21% to 150%) more costly than current market prices; however the SOFC/CAES system is the least costly of all other distributed generation technologies investigated for the case of the ExCEL building."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/17202","https://doi.org/10.71548/19966"],"dc:language.iso":["en"],"dc:subject":["SOFC","Distributed Generation","CAES"],"dc:title":["Load-following heat, hot water and power distributed generation using an integrated solid oxide fuel cell, compressed air energy storage and solar panel array system."],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:05Z"}