{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/17701"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/17701","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"An Optimization Study of an Intermittent-Flow Multistage Fluidized Ion Exchange Column with Fluid Diode Downcomers","abstract":"<p> An optimization study of an intermittent-flow multistage fluidized ion exchange column was performed using a stochastic approximation method. A new type of downcomer, a fluid diode, was designed and employed to alleviate liquid bypassing through the downcomer. The well known ion exchange system, H⁺/Na⁺ exchange on Dowex 50W resin, was used in this work. </p> <p> The volumetric efficiency of the system was optimized with regard to certain column and diode parameters. A maximum volumetric efficiency of 71.8 hr⁻¹ was obtained for the following conditions: </p> <p> average liquid flowrate = 3661 ml/min ; </p> <p> resin flowrate = 56.1 gm/min ; </p> <p> plate spacing 11.43 cm ; </p> <p> lateral diode displacement= 0.794 cm. </p> <p> Experiments have shown that a 78.2% increase in volumetric efficiency was achieved by use of the fluidic diode downcomers. </p>","abstract_html":"&lt;p&gt; An optimization study of an intermittent-flow multistage fluidized ion exchange column was performed using a stochastic approximation method. A new type of downcomer, a fluid diode, was designed and employed to alleviate liquid bypassing through the downcomer. The well known ion exchange system, H⁺/Na⁺ exchange on Dowex 50W resin, was used in this work. &lt;/p&gt; &lt;p&gt; The volumetric efficiency of the system was optimized with regard to certain column and diode parameters. A maximum volumetric efficiency of 71.8 hr⁻¹ was obtained for the following conditions: &lt;/p&gt; &lt;p&gt; average liquid flowrate = 3661 ml/min ; &lt;/p&gt; &lt;p&gt; resin flowrate = 56.1 gm/min ; &lt;/p&gt; &lt;p&gt; plate spacing 11.43 cm ; &lt;/p&gt; &lt;p&gt; lateral diode displacement= 0.794 cm. &lt;/p&gt; &lt;p&gt; Experiments have shown that a 78.2% increase in volumetric efficiency was achieved by use of the fluidic diode downcomers. &lt;/p&gt;","abstract_has_math":false,"creators":["Egan, Stephen Martin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["Shemilt, L. W."],"committee_chairs":[],"committee_members":[],"year":1971,"date_issued":"1971-10","date_published":"1971-10","updated_at":"2026-11-18T19:39:27Z","subjects":["chemical engineering","optimization study","intermittent-flow multistage fluidized","ion exchange column","fluid diode, downcomer"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/23548"],"render_values":[{"text":"https://doi.org/10.71548/23548","href":"https://doi.org/10.71548/23548","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/17701","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/17701","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F17701","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shemilt, L. W."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Egan, Stephen Martin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-07-09T17:36:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-07-09T17:36:45Z"]},{"key":"dc:date.issued","label":"Date","values":["1971-10"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["chemical engineering","optimization study","intermittent-flow multistage fluidized","ion exchange column","fluid diode, downcomer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/17701","https://doi.org/10.71548/23548"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p> An optimization study of an intermittent-flow multistage fluidized ion exchange column was performed using a stochastic approximation method. A new type of downcomer, a fluid diode, was designed and employed to alleviate liquid bypassing through the downcomer. The well known ion exchange system, H⁺/Na⁺ exchange on Dowex 50W resin, was used in this work. </p> <p> The volumetric efficiency of the system was optimized with regard to certain column and diode parameters. A maximum volumetric efficiency of 71.8 hr⁻¹ was obtained for the following conditions: </p> <p> average liquid flowrate = 3661 ml/min ; </p> <p> resin flowrate = 56.1 gm/min ; </p> <p> plate spacing 11.43 cm ; </p> <p> lateral diode displacement= 0.794 cm. </p> <p> Experiments have shown that a 78.2% increase in volumetric efficiency was achieved by use of the fluidic diode downcomers. </p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["An Optimization Study of an Intermittent-Flow Multistage Fluidized Ion Exchange Column with Fluid Diode Downcomers"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shemilt, L. W."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Egan, Stephen Martin"],"dc:date.accessioned":["2015-07-09T17:36:45Z"],"dc:date.available":["2015-07-09T17:36:45Z"],"dc:date.issued":["1971-10"],"dc:description.abstract":["<p> An optimization study of an intermittent-flow multistage fluidized ion exchange column was performed using a stochastic approximation method. A new type of downcomer, a fluid diode, was designed and employed to alleviate liquid bypassing through the downcomer. The well known ion exchange system, H⁺/Na⁺ exchange on Dowex 50W resin, was used in this work. </p> <p> The volumetric efficiency of the system was optimized with regard to certain column and diode parameters. A maximum volumetric efficiency of 71.8 hr⁻¹ was obtained for the following conditions: </p> <p> average liquid flowrate = 3661 ml/min ; </p> <p> resin flowrate = 56.1 gm/min ; </p> <p> plate spacing 11.43 cm ; </p> <p> lateral diode displacement= 0.794 cm. </p> <p> Experiments have shown that a 78.2% increase in volumetric efficiency was achieved by use of the fluidic diode downcomers. </p>"],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.uri":["http://hdl.handle.net/11375/17701","https://doi.org/10.71548/23548"],"dc:language.iso":["en"],"dc:subject":["chemical engineering","optimization study","intermittent-flow multistage fluidized","ion exchange column","fluid diode, downcomer"],"dc:title":["An Optimization Study of an Intermittent-Flow Multistage Fluidized Ion Exchange Column with Fluid Diode Downcomers"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:39:27Z"}