{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/17815"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/17815","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Predictive Stochastic Feedforward-Feedback Control of a Heat Exchanger-Stirred Tank System","abstract":"An optimal stochastic feedforward-feedback control scheme is implemented on a heat exchanger-stirred tank system using an on-line minicomputer. Because variations in the measured disturbance variable have an effect on the output controlled variable before compensating action can become effective, the feedforward action must be predictive in nature. Statistical time series models are used to model both the measured disturbance and the unobserved disturbances in the system. These stochastic disturbance models and the transfer function models for the process are identified, fitted and checked using statistical model building procedures on a set of data collected on-line using the minicomputer. The predictive feedforward-feedback controller is derived from these models. The performance of the control scheme is compared with that of a pure feedback control scheme and the actual performances are shown to conform well to the theory.","abstract_html":"An optimal stochastic feedforward-feedback control scheme is implemented on a heat exchanger-stirred tank system using an on-line minicomputer. Because variations in the measured disturbance variable have an effect on the output controlled variable before compensating action can become effective, the feedforward action must be predictive in nature. Statistical time series models are used to model both the measured disturbance and the unobserved disturbances in the system. These stochastic disturbance models and the transfer function models for the process are identified, fitted and checked using statistical model building procedures on a set of data collected on-line using the minicomputer. The predictive feedforward-feedback controller is derived from these models. The performance of the control scheme is compared with that of a pure feedback control scheme and the actual performances are shown to conform well to the theory.","abstract_has_math":false,"creators":["Goford, P."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["MacGregor, J. F.","Wright, J. D."],"committee_chairs":[],"committee_members":[],"year":1975,"date_issued":"1975-10","date_published":"1975-10","updated_at":"2026-11-18T19:38:25Z","subjects":["chemical engineering","predictive, stochastic feedforward-feedback control","heat exchanger-stirred tank system"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/20924"],"render_values":[{"text":"https://doi.org/10.71548/20924","href":"https://doi.org/10.71548/20924","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/17815","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/17815","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F17815","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["MacGregor, J. F.","Wright, J. D."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Goford, P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-07-29T13:36:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-07-29T13:36:20Z"]},{"key":"dc:date.issued","label":"Date","values":["1975-10"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["chemical engineering","predictive, stochastic feedforward-feedback control","heat exchanger-stirred tank system"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/17815","https://doi.org/10.71548/20924"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An optimal stochastic feedforward-feedback control scheme is implemented on a heat exchanger-stirred tank system using an on-line minicomputer. Because variations in the measured disturbance variable have an effect on the output controlled variable before compensating action can become effective, the feedforward action must be predictive in nature. Statistical time series models are used to model both the measured disturbance and the unobserved disturbances in the system. These stochastic disturbance models and the transfer function models for the process are identified, fitted and checked using statistical model building procedures on a set of data collected on-line using the minicomputer. The predictive feedforward-feedback controller is derived from these models. The performance of the control scheme is compared with that of a pure feedback control scheme and the actual performances are shown to conform well to the theory."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["Predictive Stochastic Feedforward-Feedback Control of a Heat Exchanger-Stirred Tank System"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["MacGregor, J. F.","Wright, J. D."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Goford, P."],"dc:date.accessioned":["2015-07-29T13:36:20Z"],"dc:date.available":["2015-07-29T13:36:20Z"],"dc:date.issued":["1975-10"],"dc:description.abstract":["An optimal stochastic feedforward-feedback control scheme is implemented on a heat exchanger-stirred tank system using an on-line minicomputer. Because variations in the measured disturbance variable have an effect on the output controlled variable before compensating action can become effective, the feedforward action must be predictive in nature. Statistical time series models are used to model both the measured disturbance and the unobserved disturbances in the system. These stochastic disturbance models and the transfer function models for the process are identified, fitted and checked using statistical model building procedures on a set of data collected on-line using the minicomputer. The predictive feedforward-feedback controller is derived from these models. The performance of the control scheme is compared with that of a pure feedback control scheme and the actual performances are shown to conform well to the theory."],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.uri":["http://hdl.handle.net/11375/17815","https://doi.org/10.71548/20924"],"dc:language.iso":["en"],"dc:subject":["chemical engineering","predictive, stochastic feedforward-feedback control","heat exchanger-stirred tank system"],"dc:title":["Predictive Stochastic Feedforward-Feedback Control of a Heat Exchanger-Stirred Tank System"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:25Z"}