{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/17932"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/17932","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Optical Density Formation in Track-Etch Radiography (Part A)","abstract":"Track-etch imaging is investigated as a recording method for neutron radiographic purposes. A theoretical model is formulated and evaluated together with experimental data which is analyzed in an attempt to explore the possibility of maximizing optical contrast. A central converter system with Lithium-6 as the converter and cellulose-nitrate as the recorders is used. It is found that the maximum contrast is achieved by using a clear cellulose-nitrate recorder at least 10 µm thick and a Lithium-6 converter of approximately 140 µm thickness.","abstract_html":"Track-etch imaging is investigated as a recording method for neutron radiographic purposes. A theoretical model is formulated and evaluated together with experimental data which is analyzed in an attempt to explore the possibility of maximizing optical contrast. A central converter system with Lithium-6 as the converter and cellulose-nitrate as the recorders is used. It is found that the maximum contrast is achieved by using a clear cellulose-nitrate recorder at least 10 µm thick and a Lithium-6 converter of approximately 140 µm thickness.","abstract_has_math":false,"creators":["Hartmann, Wolfgang Joachim"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":["Harms, A. A."],"committee_chairs":[],"committee_members":[],"year":1975,"date_issued":"1975-11","date_published":"1975-11","updated_at":"2026-11-18T19:37:34Z","subjects":["engineering physics","optical density formation","track-etch radiography","neutron radiography"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/18990"],"render_values":[{"text":"https://doi.org/10.71548/18990","href":"https://doi.org/10.71548/18990","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/17932","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/17932","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F17932","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Harms, A. A."]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["Hartmann, Wolfgang Joachim"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-08-20T12:22:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-08-20T12:22:36Z"]},{"key":"dc:date.issued","label":"Date","values":["1975-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["engineering physics","optical density formation","track-etch radiography","neutron radiography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/17932","https://doi.org/10.71548/18990"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["One of two project reports. Part B can be found at:"]},{"key":"dc:description.abstract","label":"Abstract","values":["Track-etch imaging is investigated as a recording method for neutron radiographic purposes. A theoretical model is formulated and evaluated together with experimental data which is analyzed in an attempt to explore the possibility of maximizing optical contrast. A central converter system with Lithium-6 as the converter and cellulose-nitrate as the recorders is used. It is found that the maximum contrast is achieved by using a clear cellulose-nitrate recorder at least 10 µm thick and a Lithium-6 converter of approximately 140 µm thickness."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["Optical Density Formation in Track-Etch Radiography (Part A)"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Harms, A. A."],"dc:contributor.department":["Engineering Physics"],"dc:creator":["Hartmann, Wolfgang Joachim"],"dc:date.accessioned":["2015-08-20T12:22:36Z"],"dc:date.available":["2015-08-20T12:22:36Z"],"dc:date.issued":["1975-11"],"dc:description":["One of two project reports. Part B can be found at:"],"dc:description.abstract":["Track-etch imaging is investigated as a recording method for neutron radiographic purposes. A theoretical model is formulated and evaluated together with experimental data which is analyzed in an attempt to explore the possibility of maximizing optical contrast. A central converter system with Lithium-6 as the converter and cellulose-nitrate as the recorders is used. It is found that the maximum contrast is achieved by using a clear cellulose-nitrate recorder at least 10 µm thick and a Lithium-6 converter of approximately 140 µm thickness."],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.uri":["http://hdl.handle.net/11375/17932","https://doi.org/10.71548/18990"],"dc:language.iso":["en"],"dc:subject":["engineering physics","optical density formation","track-etch radiography","neutron radiography"],"dc:title":["Optical Density Formation in Track-Etch Radiography (Part A)"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:37:34Z"}