{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/18017"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/18017","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"The Optimal Placement of Shutoff Rods in CANDU Nuclear Reactors (Part A)","abstract":"<p> The optimal placement of shutdown systems in power reactors is investigated, in particular, the placement of mechanical and liquid shutoff rods. Two CANDU reactor cores were used as a basis for evaluation. The optimal shutdown system was defined here to be one which, with the least number of rods, maximizes the reactivity depth of the system with the two most effective rods assumed to be absent. It was found that rows of rods placed parallel to the fuel channels were more effective and four of these rows were required in a simple core. For real cores where positions are limited six or seven rows were needed to obtain a large system worth. (Time analysis was not done to evaluate insertion rate and delay effects on the power transient in the case of an accident.) </p>","abstract_html":"&lt;p&gt; The optimal placement of shutdown systems in power reactors is investigated, in particular, the placement of mechanical and liquid shutoff rods. Two CANDU reactor cores were used as a basis for evaluation. The optimal shutdown system was defined here to be one which, with the least number of rods, maximizes the reactivity depth of the system with the two most effective rods assumed to be absent. It was found that rows of rods placed parallel to the fuel channels were more effective and four of these rows were required in a simple core. For real cores where positions are limited six or seven rows were needed to obtain a large system worth. (Time analysis was not done to evaluate insertion rate and delay effects on the power transient in the case of an accident.) &lt;/p&gt;","abstract_has_math":false,"creators":["Gordon, Charles W."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":["Roshd, M. H. M."],"committee_chairs":[],"committee_members":[],"year":1975,"date_issued":"1975-11","date_published":"1975-11","updated_at":"2026-11-18T19:36:37Z","subjects":["CANDU, optimal, power reactors, rods, reactivity"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/16977"],"render_values":[{"text":"https://doi.org/10.71548/16977","href":"https://doi.org/10.71548/16977","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/18017","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/18017","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F18017","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roshd, M. H. M."]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["Gordon, Charles W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-14T18:02:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-14T18:02:18Z"]},{"key":"dc:date.issued","label":"Date","values":["1975-11"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CANDU, optimal, power reactors, rods, reactivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/18017","https://doi.org/10.71548/16977"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p> The optimal placement of shutdown systems in power reactors is investigated, in particular, the placement of mechanical and liquid shutoff rods. Two CANDU reactor cores were used as a basis for evaluation. The optimal shutdown system was defined here to be one which, with the least number of rods, maximizes the reactivity depth of the system with the two most effective rods assumed to be absent. It was found that rows of rods placed parallel to the fuel channels were more effective and four of these rows were required in a simple core. For real cores where positions are limited six or seven rows were needed to obtain a large system worth. (Time analysis was not done to evaluate insertion rate and delay effects on the power transient in the case of an accident.) </p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (MEngr)"]},{"key":"dc:title","label":"Title","values":["The Optimal Placement of Shutoff Rods in CANDU Nuclear Reactors (Part A)"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Roshd, M. H. M."],"dc:contributor.department":["Engineering Physics"],"dc:creator":["Gordon, Charles W."],"dc:date.accessioned":["2015-09-14T18:02:18Z"],"dc:date.available":["2015-09-14T18:02:18Z"],"dc:date.issued":["1975-11"],"dc:description.abstract":["<p> The optimal placement of shutdown systems in power reactors is investigated, in particular, the placement of mechanical and liquid shutoff rods. Two CANDU reactor cores were used as a basis for evaluation. The optimal shutdown system was defined here to be one which, with the least number of rods, maximizes the reactivity depth of the system with the two most effective rods assumed to be absent. It was found that rows of rods placed parallel to the fuel channels were more effective and four of these rows were required in a simple core. For real cores where positions are limited six or seven rows were needed to obtain a large system worth. (Time analysis was not done to evaluate insertion rate and delay effects on the power transient in the case of an accident.) </p>"],"dc:description.degree":["Master of Engineering (MEngr)"],"dc:identifier.uri":["http://hdl.handle.net/11375/18017","https://doi.org/10.71548/16977"],"dc:language.iso":["en_US"],"dc:subject":["CANDU, optimal, power reactors, rods, reactivity"],"dc:title":["The Optimal Placement of Shutoff Rods in CANDU Nuclear Reactors (Part A)"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:36:37Z"}