{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/19496"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/19496","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"A STUDY OF POROUS ELECTRODES FOR DNA ELECTROCHEMICAL DETECTION AND THE DEVELOPMENT OF A HYBRIDIZATION EFFICIENCY CHARACTERIZATION TECHNIQUE","abstract":"Point-of-care DNA diagnostics for resource-limited settings require high sensitivity and low limits of detection but is constrained by a limitation on the complexity of instrumentation and resource consumption. To assist in the research and development of such technology, rapid-prototyping offers quick turnaround times from ideation to proof-of-concept testing at reduced costs. All-solution processed electrodes which exhibit micro/nano-scale wrinkling and porosity were rapidly-prototyped. Probe density was shown to be tunable with these electrodes and densities were greater than planar electrodes due to a surface area enhancement. Such electrodes also demonstrated favorable characteristics for the electrocatalytic detection of DNA hybridization. Characterization of hybridization efficiency for DNA biosensors often require the determination of probe and target DNA densities in separate experiments, relying on averaged measurements which lose device specificity. A new method to quantify hybridization efficiency was developed which allows the label-free, sequential determination of probe DNA and target DNA density in one experiment, allowing electrode-specific characterization of hybridization efficiency.","abstract_html":"Point-of-care DNA diagnostics for resource-limited settings require high sensitivity and low limits of detection but is constrained by a limitation on the complexity of instrumentation and resource consumption. To assist in the research and development of such technology, rapid-prototyping offers quick turnaround times from ideation to proof-of-concept testing at reduced costs. All-solution processed electrodes which exhibit micro/nano-scale wrinkling and porosity were rapidly-prototyped. Probe density was shown to be tunable with these electrodes and densities were greater than planar electrodes due to a surface area enhancement. Such electrodes also demonstrated favorable characteristics for the electrocatalytic detection of DNA hybridization. Characterization of hybridization efficiency for DNA biosensors often require the determination of probe and target DNA densities in separate experiments, relying on averaged measurements which lose device specificity. A new method to quantify hybridization efficiency was developed which allows the label-free, sequential determination of probe DNA and target DNA density in one experiment, allowing electrode-specific characterization of hybridization efficiency.","abstract_has_math":false,"creators":["Fung, Barnabas"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":["Soleymani, Leyla"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-18T19:33:38Z","subjects":["Biosensors","Electrochemical","DNA","rapid-prototyping","point-of-care"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/14631"],"render_values":[{"text":"https://doi.org/10.71548/14631","href":"https://doi.org/10.71548/14631","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/19496","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/19496","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F19496","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Soleymani, Leyla"]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["Fung, Barnabas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-06-09T13:25:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-06-09T13:25:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biosensors","Electrochemical","DNA","rapid-prototyping","point-of-care"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/19496","https://doi.org/10.71548/14631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Point-of-care DNA diagnostics for resource-limited settings require high sensitivity and low limits of detection but is constrained by a limitation on the complexity of instrumentation and resource consumption. To assist in the research and development of such technology, rapid-prototyping offers quick turnaround times from ideation to proof-of-concept testing at reduced costs. All-solution processed electrodes which exhibit micro/nano-scale wrinkling and porosity were rapidly-prototyped. Probe density was shown to be tunable with these electrodes and densities were greater than planar electrodes due to a surface area enhancement. Such electrodes also demonstrated favorable characteristics for the electrocatalytic detection of DNA hybridization. Characterization of hybridization efficiency for DNA biosensors often require the determination of probe and target DNA densities in separate experiments, relying on averaged measurements which lose device specificity. A new method to quantify hybridization efficiency was developed which allows the label-free, sequential determination of probe DNA and target DNA density in one experiment, allowing electrode-specific characterization of hybridization efficiency."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["A STUDY OF POROUS ELECTRODES FOR DNA ELECTROCHEMICAL DETECTION AND THE DEVELOPMENT OF A HYBRIDIZATION EFFICIENCY CHARACTERIZATION TECHNIQUE"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Soleymani, Leyla"],"dc:contributor.department":["Engineering Physics"],"dc:creator":["Fung, Barnabas"],"dc:date.accessioned":["2016-06-09T13:25:08Z"],"dc:date.available":["2016-06-09T13:25:08Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Point-of-care DNA diagnostics for resource-limited settings require high sensitivity and low limits of detection but is constrained by a limitation on the complexity of instrumentation and resource consumption. To assist in the research and development of such technology, rapid-prototyping offers quick turnaround times from ideation to proof-of-concept testing at reduced costs. All-solution processed electrodes which exhibit micro/nano-scale wrinkling and porosity were rapidly-prototyped. Probe density was shown to be tunable with these electrodes and densities were greater than planar electrodes due to a surface area enhancement. Such electrodes also demonstrated favorable characteristics for the electrocatalytic detection of DNA hybridization. Characterization of hybridization efficiency for DNA biosensors often require the determination of probe and target DNA densities in separate experiments, relying on averaged measurements which lose device specificity. A new method to quantify hybridization efficiency was developed which allows the label-free, sequential determination of probe DNA and target DNA density in one experiment, allowing electrode-specific characterization of hybridization efficiency."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/19496","https://doi.org/10.71548/14631"],"dc:language.iso":["en"],"dc:subject":["Biosensors","Electrochemical","DNA","rapid-prototyping","point-of-care"],"dc:title":["A STUDY OF POROUS ELECTRODES FOR DNA ELECTROCHEMICAL DETECTION AND THE DEVELOPMENT OF A HYBRIDIZATION EFFICIENCY CHARACTERIZATION TECHNIQUE"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:33:38Z"}