{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/19588"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/19588","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking","abstract":"<p>In this report various means of infra-red laser radiation detection were investigated. For the measurement of the energy of pulses of 10.6 μm laser radiation for energies up to 15-20 joules and also for energies up to 200 joules, two pyroelectric detector designs were researched. These two detector designs acted as monitors, using 10% of the beam for detection and allowing 90% to be used for other purposes. Responsivities of as much as 120 mV/J for the 15-20 joule detector and 16.7 mV/J for the 200 joule detector were obtained.</p> <p>Also three types of photon drag materials, used for pulse shape analysis and power detection were investigated. InAs and Te were compared to Ge for a possible faster and more sensitive alternative. Also a means of impedance matching and amplifying the output of these rather low sensitivity detectors using a magnetic current probe was analyzed.</p> <p>Finally an inexpensive and easily constructed container and mount for the 15-20 joules pyroelectric detector was designed along with an attachment to the Lumonics series 100 TEA lasers for ease of alignment with the beam.</p>","abstract_html":"&lt;p&gt;In this report various means of infra-red laser radiation detection were investigated. For the measurement of the energy of pulses of 10.6 μm laser radiation for energies up to 15-20 joules and also for energies up to 200 joules, two pyroelectric detector designs were researched. These two detector designs acted as monitors, using 10% of the beam for detection and allowing 90% to be used for other purposes. Responsivities of as much as 120 mV/J for the 15-20 joule detector and 16.7 mV/J for the 200 joule detector were obtained.&lt;/p&gt; &lt;p&gt;Also three types of photon drag materials, used for pulse shape analysis and power detection were investigated. InAs and Te were compared to Ge for a possible faster and more sensitive alternative. Also a means of impedance matching and amplifying the output of these rather low sensitivity detectors using a magnetic current probe was analyzed.&lt;/p&gt; &lt;p&gt;Finally an inexpensive and easily constructed container and mount for the 15-20 joules pyroelectric detector was designed along with an attachment to the Lumonics series 100 TEA lasers for ease of alignment with the beam.&lt;/p&gt;","abstract_has_math":false,"creators":["Malcolm, John W. T."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1972,"date_issued":"1972","date_published":"1972","updated_at":"2026-11-18T19:32:59Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/13033"],"render_values":[{"text":"https://doi.org/10.71548/13033","href":"https://doi.org/10.71548/13033","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/19588","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/19588","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F19588","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["Malcolm, John W. T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-06-20T17:12:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-06-20T17:12:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1972"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/19588","https://doi.org/10.71548/13033"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title: Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking, Author: John W. T. Malcolm, Location: Thode"]},{"key":"dc:description.abstract","label":"Abstract","values":["<p>In this report various means of infra-red laser radiation detection were investigated. For the measurement of the energy of pulses of 10.6 μm laser radiation for energies up to 15-20 joules and also for energies up to 200 joules, two pyroelectric detector designs were researched. These two detector designs acted as monitors, using 10% of the beam for detection and allowing 90% to be used for other purposes. Responsivities of as much as 120 mV/J for the 15-20 joule detector and 16.7 mV/J for the 200 joule detector were obtained.</p> <p>Also three types of photon drag materials, used for pulse shape analysis and power detection were investigated. InAs and Te were compared to Ge for a possible faster and more sensitive alternative. Also a means of impedance matching and amplifying the output of these rather low sensitivity detectors using a magnetic current probe was analyzed.</p> <p>Finally an inexpensive and easily constructed container and mount for the 15-20 joules pyroelectric detector was designed along with an attachment to the Lumonics series 100 TEA lasers for ease of alignment with the beam.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.department":["Engineering Physics"],"dc:creator":["Malcolm, John W. T."],"dc:date.accessioned":["2016-06-20T17:12:51Z"],"dc:date.available":["2016-06-20T17:12:51Z"],"dc:date.issued":["1972"],"dc:description":["Title: Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking, Author: John W. T. Malcolm, Location: Thode"],"dc:description.abstract":["<p>In this report various means of infra-red laser radiation detection were investigated. For the measurement of the energy of pulses of 10.6 μm laser radiation for energies up to 15-20 joules and also for energies up to 200 joules, two pyroelectric detector designs were researched. These two detector designs acted as monitors, using 10% of the beam for detection and allowing 90% to be used for other purposes. Responsivities of as much as 120 mV/J for the 15-20 joule detector and 16.7 mV/J for the 200 joule detector were obtained.</p> <p>Also three types of photon drag materials, used for pulse shape analysis and power detection were investigated. InAs and Te were compared to Ge for a possible faster and more sensitive alternative. Also a means of impedance matching and amplifying the output of these rather low sensitivity detectors using a magnetic current probe was analyzed.</p> <p>Finally an inexpensive and easily constructed container and mount for the 15-20 joules pyroelectric detector was designed along with an attachment to the Lumonics series 100 TEA lasers for ease of alignment with the beam.</p>"],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.uri":["http://hdl.handle.net/11375/19588","https://doi.org/10.71548/13033"],"dc:language.iso":["en"],"dc:title":["Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:32:59Z"}