{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/20018"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/20018","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Heat Transfer to Sprays and Flowing Gases","abstract":"<p>An experimental investigation of an Atomized Suspension Technique system was carried out in an experimental apparatus of semi-pilot plant scale. The complex gas flow patterns which occur in such systems as the result of the interaction of natural convection and forced convection prevented a quantitative analysis of the system.</p> <p>The problem was then approached by dividing the overall process into a number of idealized studies; these were convection in the entrance region, radiation to a gas, radiation to a cloud of droplets.</p> <p>A theoretical model was developed to predict heat-transfer rates and gas temperature profiles in the entrance region (x/D < 2) of a cylindrical coolumn. The model was verified experimentally.</p> <p>A theoretical gas- radiation model was developed using the zoning technique of Hottel. Experimental gas-temperature measurerrents qualitatively verified the model.</p> <p>An investigation of the established immersion cell technique for the determination of drop-size distributions in sprays indicated that this technique could not be used with any confidence in systems where the spray is moving at low velocities.</p> <p>Several experimental devices and techniques were developed throughout the course of this study.</p>","abstract_html":"&lt;p&gt;An experimental investigation of an Atomized Suspension Technique system was carried out in an experimental apparatus of semi-pilot plant scale. The complex gas flow patterns which occur in such systems as the result of the interaction of natural convection and forced convection prevented a quantitative analysis of the system.&lt;/p&gt; &lt;p&gt;The problem was then approached by dividing the overall process into a number of idealized studies; these were convection in the entrance region, radiation to a gas, radiation to a cloud of droplets.&lt;/p&gt; &lt;p&gt;A theoretical model was developed to predict heat-transfer rates and gas temperature profiles in the entrance region (x/D &lt; 2) of a cylindrical coolumn. The model was verified experimentally.&lt;/p&gt; &lt;p&gt;A theoretical gas- radiation model was developed using the zoning technique of Hottel. Experimental gas-temperature measurerrents qualitatively verified the model.&lt;/p&gt; &lt;p&gt;An investigation of the established immersion cell technique for the determination of drop-size distributions in sprays indicated that this technique could not be used with any confidence in systems where the spray is moving at low velocities.&lt;/p&gt; &lt;p&gt;Several experimental devices and techniques were developed throughout the course of this study.&lt;/p&gt;","abstract_has_math":false,"creators":["Pollock, Kenneth G."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["Hoffman, T.W."],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967-10","date_published":"1967-10","updated_at":"2026-11-18T19:39:41Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/23667"],"render_values":[{"text":"https://doi.org/10.71548/23667","href":"https://doi.org/10.71548/23667","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/20018","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/20018","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F20018","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hoffman, T.W."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Pollock, Kenneth G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-03T14:51:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-03T14:51:57Z"]},{"key":"dc:date.issued","label":"Date","values":["1967-10"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/20018","https://doi.org/10.71548/23667"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Title: Heat Transfer to Sprays and Flowing Gases, Author: Kenneth G. Pollock, Location: Thode"]},{"key":"dc:description.abstract","label":"Abstract","values":["<p>An experimental investigation of an Atomized Suspension Technique system was carried out in an experimental apparatus of semi-pilot plant scale. The complex gas flow patterns which occur in such systems as the result of the interaction of natural convection and forced convection prevented a quantitative analysis of the system.</p> <p>The problem was then approached by dividing the overall process into a number of idealized studies; these were convection in the entrance region, radiation to a gas, radiation to a cloud of droplets.</p> <p>A theoretical model was developed to predict heat-transfer rates and gas temperature profiles in the entrance region (x/D < 2) of a cylindrical coolumn. The model was verified experimentally.</p> <p>A theoretical gas- radiation model was developed using the zoning technique of Hottel. Experimental gas-temperature measurerrents qualitatively verified the model.</p> <p>An investigation of the established immersion cell technique for the determination of drop-size distributions in sprays indicated that this technique could not be used with any confidence in systems where the spray is moving at low velocities.</p> <p>Several experimental devices and techniques were developed throughout the course of this study.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy (PhD)"]},{"key":"dc:title","label":"Title","values":["Heat Transfer to Sprays and Flowing Gases"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hoffman, T.W."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Pollock, Kenneth G."],"dc:date.accessioned":["2016-08-03T14:51:57Z"],"dc:date.available":["2016-08-03T14:51:57Z"],"dc:date.issued":["1967-10"],"dc:description":["Title: Heat Transfer to Sprays and Flowing Gases, Author: Kenneth G. Pollock, Location: Thode"],"dc:description.abstract":["<p>An experimental investigation of an Atomized Suspension Technique system was carried out in an experimental apparatus of semi-pilot plant scale. The complex gas flow patterns which occur in such systems as the result of the interaction of natural convection and forced convection prevented a quantitative analysis of the system.</p> <p>The problem was then approached by dividing the overall process into a number of idealized studies; these were convection in the entrance region, radiation to a gas, radiation to a cloud of droplets.</p> <p>A theoretical model was developed to predict heat-transfer rates and gas temperature profiles in the entrance region (x/D < 2) of a cylindrical coolumn. The model was verified experimentally.</p> <p>A theoretical gas- radiation model was developed using the zoning technique of Hottel. Experimental gas-temperature measurerrents qualitatively verified the model.</p> <p>An investigation of the established immersion cell technique for the determination of drop-size distributions in sprays indicated that this technique could not be used with any confidence in systems where the spray is moving at low velocities.</p> <p>Several experimental devices and techniques were developed throughout the course of this study.</p>"],"dc:description.degree":["Doctor of Philosophy (PhD)"],"dc:identifier.uri":["http://hdl.handle.net/11375/20018","https://doi.org/10.71548/23667"],"dc:language.iso":["en"],"dc:title":["Heat Transfer to Sprays and Flowing Gases"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:39:41Z"}