{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/20647"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/20647","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"A Mechanistic Model to Predict Fuel Channel Failure in the Event of Pressure Tube Overheating","abstract":"Under normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event.","abstract_html":"Under normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event.","abstract_has_math":false,"creators":["Dion, Alexander"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":["Luxat, John"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T05:55:01Z","subjects":["Thermal Hydraulics","CANDU","Fuel Channel Failure","Film Boiling"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/13719"],"render_values":[{"text":"https://doi.org/10.71548/13719","href":"https://doi.org/10.71548/13719","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/20647","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/20647","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F20647","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Luxat, John"]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["Dion, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-10-05T19:40:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-10-05T19:40:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Thermal Hydraulics","CANDU","Fuel Channel Failure","Film Boiling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/20647","https://doi.org/10.71548/13719"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Under normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Computer software was developed to predict CANDU fuel channel failure in the event of a total station blackout. The model created successfully predicted the available experimental data."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["A Mechanistic Model to Predict Fuel Channel Failure in the Event of Pressure Tube Overheating"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["A Model to Predict Fuel Channel Failure"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Luxat, John"],"dc:contributor.department":["Engineering Physics"],"dc:creator":["Dion, Alexander"],"dc:date.accessioned":["2016-10-05T19:40:24Z"],"dc:date.available":["2016-10-05T19:40:24Z"],"dc:date.issued":["2016"],"dc:description.abstract":["Under normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event."],"dc:description.abstractgeneral":["Computer software was developed to predict CANDU fuel channel failure in the event of a total station blackout. The model created successfully predicted the available experimental data."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/20647","https://doi.org/10.71548/13719"],"dc:language.iso":["en"],"dc:subject":["Thermal Hydraulics","CANDU","Fuel Channel Failure","Film Boiling"],"dc:title":["A Mechanistic Model to Predict Fuel Channel Failure in the Event of Pressure Tube Overheating"],"dc:title.alternative":["A Model to Predict Fuel Channel Failure"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-19T05:55:01Z"}