{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/23998"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/23998","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Design and Characterization of a Miniaturized Fluorescence Analysis System for Measurement of Cell-Free DNA","abstract":"Sepsis is a dysregulated systemic response to infection and is one of the leading causes of in-hospital mortality in Canada. Accurate distinction between survivors and non-survivors of sepsis has recently been demonstrated through quantification of cell-free DNA (cfDNA) concentration in blood. In an analysis of 80 septic patients, non-survivors of sepsis had significantly higher cfDNA concentration levels than that of survivors or healthy patients. Real time separation of cfDNA from contaminants in blood has also been done using a cross channel microfluidic device. Current methods for DNA quantification utilize time consuming and complicated laboratory equipment and therefore are not suitable for bedside real-time testing. Thus a handheld cfDNA fluorescence device coined the Sepsis Check was designed that can perform DNA characterization in a reservoir device and DNA detection in a microfluidic cross channel device. The goal is to use this system along with the cross channel devices to set apart survivors or healthy donors from non-survivors in patients with sepsis. The design consists of a 470𝑛𝑚 light emitting diode (LED) with 170𝑚𝑊 of optical power (LED470L – ThorLabs), an aspherical uncoated lens with a focal length of 15𝑚𝑚 (LA1540-ML – ThorLabs), a 488𝑛𝑚 bandpass filter with a 3𝑛𝑚 full width at half maximum (FWHM) (FL05488-3 – ThorLabs), an aspherical uncoated lens with a focal length of 25𝑚𝑚 (LA1560-ML – ThorLabs), an aspherical uncoated lens with a focal length of 35𝑚𝑚 (LA1027-ML – ThorLabs), a 525𝑛𝑚 longpass filter with an optical density >4.0 (F84744 – Edmund Optics), and a Raspberry Pi Camera V2 (Raspberry Pi Foundation). The Sepsis Check is made to excite the dsDNA specific PicoGreen fluorophore which has a peak absorbance at 502𝑛𝑚 and a peak emission at 523𝑛𝑚. In summary, the Sepsis Check in this thesis is capable of calibrating dsDNA concentration from 1𝜇𝑔/𝑚𝐿 to 10𝜇𝑔/𝑚𝐿 and detect DNA accumulation of 5𝜇𝑔/𝑚𝐿 and 10𝜇𝑔/𝑚𝐿 in the cross channel device. This tool can be a valuable addition to the ICU to rapidly assess the severity of sepsis for informed decision making.","abstract_html":"Sepsis is a dysregulated systemic response to infection and is one of the leading causes of in-hospital mortality in Canada. Accurate distinction between survivors and non-survivors of sepsis has recently been demonstrated through quantification of cell-free DNA (cfDNA) concentration in blood. In an analysis of 80 septic patients, non-survivors of sepsis had significantly higher cfDNA concentration levels than that of survivors or healthy patients. Real time separation of cfDNA from contaminants in blood has also been done using a cross channel microfluidic device. Current methods for DNA quantification utilize time consuming and complicated laboratory equipment and therefore are not suitable for bedside real-time testing. Thus a handheld cfDNA fluorescence device coined the Sepsis Check was designed that can perform DNA characterization in a reservoir device and DNA detection in a microfluidic cross channel device. The goal is to use this system along with the cross channel devices to set apart survivors or healthy donors from non-survivors in patients with sepsis. The design consists of a 470𝑛𝑚 light emitting diode (LED) with 170𝑚𝑊 of optical power (LED470L – ThorLabs), an aspherical uncoated lens with a focal length of 15𝑚𝑚 (LA1540-ML – ThorLabs), a 488𝑛𝑚 bandpass filter with a 3𝑛𝑚 full width at half maximum (FWHM) (FL05488-3 – ThorLabs), an aspherical uncoated lens with a focal length of 25𝑚𝑚 (LA1560-ML – ThorLabs), an aspherical uncoated lens with a focal length of 35𝑚𝑚 (LA1027-ML – ThorLabs), a 525𝑛𝑚 longpass filter with an optical density &gt;4.0 (F84744 – Edmund Optics), and a Raspberry Pi Camera V2 (Raspberry Pi Foundation). The Sepsis Check is made to excite the dsDNA specific PicoGreen fluorophore which has a peak absorbance at 502𝑛𝑚 and a peak emission at 523𝑛𝑚. In summary, the Sepsis Check in this thesis is capable of calibrating dsDNA concentration from 1𝜇𝑔/𝑚𝐿 to 10𝜇𝑔/𝑚𝐿 and detect DNA accumulation of 5𝜇𝑔/𝑚𝐿 and 10𝜇𝑔/𝑚𝐿 in the cross channel device. This tool can be a valuable addition to the ICU to rapidly assess the severity of sepsis for informed decision making.","abstract_has_math":false,"creators":["Bondi, Parker"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Selvaganapathy, Ravi"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-11-30","date_published":"2018-11-30","updated_at":"2026-11-18T19:33:28Z","subjects":["Miniaturized Fluorescence System","Cell-Free-DNA","Sepsis Quantification"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/14167"],"render_values":[{"text":"https://doi.org/10.71548/14167","href":"https://doi.org/10.71548/14167","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/23998","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/23998","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F23998","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Selvaganapathy, Ravi"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bondi, Parker"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-03-12T18:54:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-03-12T18:54:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-11-30"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Miniaturized Fluorescence System","Cell-Free-DNA","Sepsis Quantification"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/23998","https://doi.org/10.71548/14167"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Sepsis is a dysregulated systemic response to infection and is one of the leading causes of in-hospital mortality in Canada. Accurate distinction between survivors and non-survivors of sepsis has recently been demonstrated through quantification of cell-free DNA (cfDNA) concentration in blood. In an analysis of 80 septic patients, non-survivors of sepsis had significantly higher cfDNA concentration levels than that of survivors or healthy patients. Real time separation of cfDNA from contaminants in blood has also been done using a cross channel microfluidic device. Current methods for DNA quantification utilize time consuming and complicated laboratory equipment and therefore are not suitable for bedside real-time testing. Thus a handheld cfDNA fluorescence device coined the Sepsis Check was designed that can perform DNA characterization in a reservoir device and DNA detection in a microfluidic cross channel device. The goal is to use this system along with the cross channel devices to set apart survivors or healthy donors from non-survivors in patients with sepsis. The design consists of a 470𝑛𝑚 light emitting diode (LED) with 170𝑚𝑊 of optical power (LED470L – ThorLabs), an aspherical uncoated lens with a focal length of 15𝑚𝑚 (LA1540-ML – ThorLabs), a 488𝑛𝑚 bandpass filter with a 3𝑛𝑚 full width at half maximum (FWHM) (FL05488-3 – ThorLabs), an aspherical uncoated lens with a focal length of 25𝑚𝑚 (LA1560-ML – ThorLabs), an aspherical uncoated lens with a focal length of 35𝑚𝑚 (LA1027-ML – ThorLabs), a 525𝑛𝑚 longpass filter with an optical density >4.0 (F84744 – Edmund Optics), and a Raspberry Pi Camera V2 (Raspberry Pi Foundation). The Sepsis Check is made to excite the dsDNA specific PicoGreen fluorophore which has a peak absorbance at 502𝑛𝑚 and a peak emission at 523𝑛𝑚. In summary, the Sepsis Check in this thesis is capable of calibrating dsDNA concentration from 1𝜇𝑔/𝑚𝐿 to 10𝜇𝑔/𝑚𝐿 and detect DNA accumulation of 5𝜇𝑔/𝑚𝐿 and 10𝜇𝑔/𝑚𝐿 in the cross channel device. This tool can be a valuable addition to the ICU to rapidly assess the severity of sepsis for informed decision making."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["Design and Characterization of a Miniaturized Fluorescence Analysis System for Measurement of Cell-Free DNA"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Selvaganapathy, Ravi"],"dc:contributor.department":["Biomedical Engineering"],"dc:creator":["Bondi, Parker"],"dc:date.accessioned":["2019-03-12T18:54:41Z"],"dc:date.available":["2019-03-12T18:54:41Z"],"dc:date.issued":["2018-11-30"],"dc:description.abstract":["Sepsis is a dysregulated systemic response to infection and is one of the leading causes of in-hospital mortality in Canada. Accurate distinction between survivors and non-survivors of sepsis has recently been demonstrated through quantification of cell-free DNA (cfDNA) concentration in blood. In an analysis of 80 septic patients, non-survivors of sepsis had significantly higher cfDNA concentration levels than that of survivors or healthy patients. Real time separation of cfDNA from contaminants in blood has also been done using a cross channel microfluidic device. Current methods for DNA quantification utilize time consuming and complicated laboratory equipment and therefore are not suitable for bedside real-time testing. Thus a handheld cfDNA fluorescence device coined the Sepsis Check was designed that can perform DNA characterization in a reservoir device and DNA detection in a microfluidic cross channel device. The goal is to use this system along with the cross channel devices to set apart survivors or healthy donors from non-survivors in patients with sepsis. The design consists of a 470𝑛𝑚 light emitting diode (LED) with 170𝑚𝑊 of optical power (LED470L – ThorLabs), an aspherical uncoated lens with a focal length of 15𝑚𝑚 (LA1540-ML – ThorLabs), a 488𝑛𝑚 bandpass filter with a 3𝑛𝑚 full width at half maximum (FWHM) (FL05488-3 – ThorLabs), an aspherical uncoated lens with a focal length of 25𝑚𝑚 (LA1560-ML – ThorLabs), an aspherical uncoated lens with a focal length of 35𝑚𝑚 (LA1027-ML – ThorLabs), a 525𝑛𝑚 longpass filter with an optical density >4.0 (F84744 – Edmund Optics), and a Raspberry Pi Camera V2 (Raspberry Pi Foundation). The Sepsis Check is made to excite the dsDNA specific PicoGreen fluorophore which has a peak absorbance at 502𝑛𝑚 and a peak emission at 523𝑛𝑚. In summary, the Sepsis Check in this thesis is capable of calibrating dsDNA concentration from 1𝜇𝑔/𝑚𝐿 to 10𝜇𝑔/𝑚𝐿 and detect DNA accumulation of 5𝜇𝑔/𝑚𝐿 and 10𝜇𝑔/𝑚𝐿 in the cross channel device. This tool can be a valuable addition to the ICU to rapidly assess the severity of sepsis for informed decision making."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/23998","https://doi.org/10.71548/14167"],"dc:language.iso":["en"],"dc:subject":["Miniaturized Fluorescence System","Cell-Free-DNA","Sepsis Quantification"],"dc:title":["Design and Characterization of a Miniaturized Fluorescence Analysis System for Measurement of Cell-Free DNA"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:33:28Z"}