{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/26068"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/26068","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Mismatch Negativity and General Anesthesia","abstract":"In order to further explore the nature of anesthesia-induced unconsciousness and its relationship to nociception, investigators attempted to determine whether mismatch negativity could be detected during general anesthesia and surgery. An auditory odd-ball paradigm designed to elicit mismatch negativity was presented to ten patients during general anesthesia and surgery. Five of the ten also underwent testing in the awake state prior to surgery. Multiple EEG recordings were obtained in each patient and each condition using the BioSemi ActiveTwo 64 EEG electrode system. The anesthetic regime required only that 0.7 MAC of an inhaled agent was administered. Several methods of analysis were utilized to determine whether an MMN response could be identified: visual inspection of ERP waveforms, targeted t-tests, cluster permutation tests, and multivariate pattern analysis. Whereas deviant-related negativity was readily detected in the awake state, deviant-related negativity was not detected during surgery and general anesthesia. Results demonstrate that essential components of the MMN response are abolished during typically conducted general anesthesia even with significant surgical stimulation. These results are consistent with previous research on ERPs and anesthesia. Results cast doubt on the possibility of sensory memory related to intraoperative events.","abstract_html":"In order to further explore the nature of anesthesia-induced unconsciousness and its relationship to nociception, investigators attempted to determine whether mismatch negativity could be detected during general anesthesia and surgery. An auditory odd-ball paradigm designed to elicit mismatch negativity was presented to ten patients during general anesthesia and surgery. Five of the ten also underwent testing in the awake state prior to surgery. Multiple EEG recordings were obtained in each patient and each condition using the BioSemi ActiveTwo 64 EEG electrode system. The anesthetic regime required only that 0.7 MAC of an inhaled agent was administered. Several methods of analysis were utilized to determine whether an MMN response could be identified: visual inspection of ERP waveforms, targeted t-tests, cluster permutation tests, and multivariate pattern analysis. Whereas deviant-related negativity was readily detected in the awake state, deviant-related negativity was not detected during surgery and general anesthesia. Results demonstrate that essential components of the MMN response are abolished during typically conducted general anesthesia even with significant surgical stimulation. These results are consistent with previous research on ERPs and anesthesia. Results cast doubt on the possibility of sensory memory related to intraoperative events.","abstract_has_math":false,"creators":["Kolesar, Richard"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Neuroscience","school":null,"contributors":[],"advisors":["Connolly, John","Service, Elisabet","Goldreich, Daniel"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-18T19:31:23Z","subjects":["Consciousness","Event-related potentials","Auditory processing","General anesthesia"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/9729"],"render_values":[{"text":"https://doi.org/10.71548/9729","href":"https://doi.org/10.71548/9729","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/26068","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/26068","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F26068","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Connolly, John","Service, Elisabet","Goldreich, Daniel"]},{"key":"dc:contributor.department","label":"Department","values":["Neuroscience"]},{"key":"dc:creator","label":"Author","values":["Kolesar, Richard"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-12-03T21:11:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-12-03T21:11:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Consciousness","Event-related potentials","Auditory processing","General anesthesia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/26068","https://doi.org/10.71548/9729"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to further explore the nature of anesthesia-induced unconsciousness and its relationship to nociception, investigators attempted to determine whether mismatch negativity could be detected during general anesthesia and surgery. An auditory odd-ball paradigm designed to elicit mismatch negativity was presented to ten patients during general anesthesia and surgery. Five of the ten also underwent testing in the awake state prior to surgery. Multiple EEG recordings were obtained in each patient and each condition using the BioSemi ActiveTwo 64 EEG electrode system. The anesthetic regime required only that 0.7 MAC of an inhaled agent was administered. Several methods of analysis were utilized to determine whether an MMN response could be identified: visual inspection of ERP waveforms, targeted t-tests, cluster permutation tests, and multivariate pattern analysis. Whereas deviant-related negativity was readily detected in the awake state, deviant-related negativity was not detected during surgery and general anesthesia. Results demonstrate that essential components of the MMN response are abolished during typically conducted general anesthesia even with significant surgical stimulation. These results are consistent with previous research on ERPs and anesthesia. Results cast doubt on the possibility of sensory memory related to intraoperative events."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (MSc)"]},{"key":"dc:title","label":"Title","values":["Mismatch Negativity and General Anesthesia"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Connolly, John","Service, Elisabet","Goldreich, Daniel"],"dc:contributor.department":["Neuroscience"],"dc:creator":["Kolesar, Richard"],"dc:date.accessioned":["2020-12-03T21:11:18Z"],"dc:date.available":["2020-12-03T21:11:18Z"],"dc:date.issued":["2020"],"dc:description.abstract":["In order to further explore the nature of anesthesia-induced unconsciousness and its relationship to nociception, investigators attempted to determine whether mismatch negativity could be detected during general anesthesia and surgery. An auditory odd-ball paradigm designed to elicit mismatch negativity was presented to ten patients during general anesthesia and surgery. Five of the ten also underwent testing in the awake state prior to surgery. Multiple EEG recordings were obtained in each patient and each condition using the BioSemi ActiveTwo 64 EEG electrode system. The anesthetic regime required only that 0.7 MAC of an inhaled agent was administered. Several methods of analysis were utilized to determine whether an MMN response could be identified: visual inspection of ERP waveforms, targeted t-tests, cluster permutation tests, and multivariate pattern analysis. Whereas deviant-related negativity was readily detected in the awake state, deviant-related negativity was not detected during surgery and general anesthesia. Results demonstrate that essential components of the MMN response are abolished during typically conducted general anesthesia even with significant surgical stimulation. These results are consistent with previous research on ERPs and anesthesia. Results cast doubt on the possibility of sensory memory related to intraoperative events."],"dc:description.degree":["Master of Science (MSc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/26068","https://doi.org/10.71548/9729"],"dc:language.iso":["en"],"dc:subject":["Consciousness","Event-related potentials","Auditory processing","General anesthesia"],"dc:title":["Mismatch Negativity and General Anesthesia"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:31:23Z"}