{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/30589"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/30589","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS","abstract":"Time-to-digital converters (TDC) and single-photon avalanche diodes (SPAD) can be integrated together into SPAD-imagers. TDC is a mixed-signal circuit that can convert the time differences between the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the reference clock to extract time-of flight (ToF) data. The performance of TDC is directly related to the temporal performance of the SPAD-imagers in biomedical imaging systems, such as positron emission tomography (PET) and diffuse optical tomography (DOT). In recent years, the evolution of modern complementary metal-oxide-semiconductor (CMOS) technology made it possible to implant SPAD-imagers for imaging neural activities in moving subjects. This work proposes a new TDC design to further improve future SPAD-imager based time-domain imaging systems. Firstly, this thesis provides a detailed review of the current research on brain imaging and neural activity recording methods. Next, the operating principles of different TDC architectures are presented. In the following chapter, the proposed time amplified, stochastic phase interpolation (TASPI) TDC architecture was designed and tested in TSMC 65 nm standard CMOS technology nodes that can achieve a ~16 ps resolution with 6 effective number of bits in a 0.06 mm2 silicon area is presented. Based on the results, areas for future improvements are identified and discussed in detail.","abstract_html":"Time-to-digital converters (TDC) and single-photon avalanche diodes (SPAD) can be integrated together into SPAD-imagers. TDC is a mixed-signal circuit that can convert the time differences between the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the reference clock to extract time-of flight (ToF) data. The performance of TDC is directly related to the temporal performance of the SPAD-imagers in biomedical imaging systems, such as positron emission tomography (PET) and diffuse optical tomography (DOT). In recent years, the evolution of modern complementary metal-oxide-semiconductor (CMOS) technology made it possible to implant SPAD-imagers for imaging neural activities in moving subjects. This work proposes a new TDC design to further improve future SPAD-imager based time-domain imaging systems. Firstly, this thesis provides a detailed review of the current research on brain imaging and neural activity recording methods. Next, the operating principles of different TDC architectures are presented. In the following chapter, the proposed time amplified, stochastic phase interpolation (TASPI) TDC architecture was designed and tested in TSMC 65 nm standard CMOS technology nodes that can achieve a ~16 ps resolution with 6 effective number of bits in a 0.06 mm2 silicon area is presented. Based on the results, areas for future improvements are identified and discussed in detail.","abstract_has_math":false,"creators":["Liu, Chengxin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Deen, M.Jamal"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-18T19:36:15Z","subjects":["Time-to-digital converter","biomedical imaging"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/16040"],"render_values":[{"text":"https://doi.org/10.71548/16040","href":"https://doi.org/10.71548/16040","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/30589","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/30589","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F30589","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Deen, M.Jamal"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Liu, Chengxin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-11-22T19:28:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-11-22T19:28:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Time-to-digital converter","biomedical imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/30589","https://doi.org/10.71548/16040"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Time-to-digital converters (TDC) and single-photon avalanche diodes (SPAD) can be integrated together into SPAD-imagers. TDC is a mixed-signal circuit that can convert the time differences between the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the reference clock to extract time-of flight (ToF) data. The performance of TDC is directly related to the temporal performance of the SPAD-imagers in biomedical imaging systems, such as positron emission tomography (PET) and diffuse optical tomography (DOT). In recent years, the evolution of modern complementary metal-oxide-semiconductor (CMOS) technology made it possible to implant SPAD-imagers for imaging neural activities in moving subjects. This work proposes a new TDC design to further improve future SPAD-imager based time-domain imaging systems. Firstly, this thesis provides a detailed review of the current research on brain imaging and neural activity recording methods. Next, the operating principles of different TDC architectures are presented. In the following chapter, the proposed time amplified, stochastic phase interpolation (TASPI) TDC architecture was designed and tested in TSMC 65 nm standard CMOS technology nodes that can achieve a ~16 ps resolution with 6 effective number of bits in a 0.06 mm2 silicon area is presented. Based on the results, areas for future improvements are identified and discussed in detail."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Deen, M.Jamal"],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Liu, Chengxin"],"dc:date.accessioned":["2024-11-22T19:28:10Z"],"dc:date.available":["2024-11-22T19:28:10Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Time-to-digital converters (TDC) and single-photon avalanche diodes (SPAD) can be integrated together into SPAD-imagers. TDC is a mixed-signal circuit that can convert the time differences between the two input signals. In SPAD-imagers, the electrical pulses triggered by incident photons are measured against the reference clock to extract time-of flight (ToF) data. The performance of TDC is directly related to the temporal performance of the SPAD-imagers in biomedical imaging systems, such as positron emission tomography (PET) and diffuse optical tomography (DOT). In recent years, the evolution of modern complementary metal-oxide-semiconductor (CMOS) technology made it possible to implant SPAD-imagers for imaging neural activities in moving subjects. This work proposes a new TDC design to further improve future SPAD-imager based time-domain imaging systems. Firstly, this thesis provides a detailed review of the current research on brain imaging and neural activity recording methods. Next, the operating principles of different TDC architectures are presented. In the following chapter, the proposed time amplified, stochastic phase interpolation (TASPI) TDC architecture was designed and tested in TSMC 65 nm standard CMOS technology nodes that can achieve a ~16 ps resolution with 6 effective number of bits in a 0.06 mm2 silicon area is presented. Based on the results, areas for future improvements are identified and discussed in detail."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["http://hdl.handle.net/11375/30589","https://doi.org/10.71548/16040"],"dc:language.iso":["en"],"dc:subject":["Time-to-digital converter","biomedical imaging"],"dc:title":["DESIGN OF A TIME-AMPLIFIED, STOCHASTIC PHASE INTERPOLATION TIME-TO-DIGITAL-CONVERTER FOR BIOMEDICAL IMAGING APPLICATIONS"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:36:15Z"}