{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/33133"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/33133","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Hand-Eye Calibration of Multiple Monocular Cameras","abstract":"Cameras are a common and cost-effective sensing modality for robotic platforms, enabling systems to collect visual information about their operating environment and support downstream perception tasks. In particular, the pose of each camera relative to the robot frame must be defined with respect to a known reference through a process known as extrinsic calibration. Each new sensor added to a robotic system must be incorporated into the calibrated configuration, which increases the calibration effort for both new and existing robotic systems. Over the operational lifespan of a robotic system, mechanical shock, structural drift, or maintenance activities may alter the physical configuration of mounted cameras, compromising previously estimated extrinsic parameters and necessitating recalibration. Camera calibration typically requires moving the robotic platform through a range of poses to collect imagery of the surrounding environment. Establishing correspondences between two-dimensional image observations and three-dimensional scene structure generally requires knowledge of a baseline that enables depth estimation. Such information may be obtained through engineered calibration targets, sensor fusion with depth-measuring instruments, or stereo camera configurations with known baselines. In this work, we present the design and implementation of a procedure for calibrating the extrinsic parameters of multiple cameras mounted on a robotic platform without requiring explicit depth measurements. The proposed approach leverages pairwise two-view geometry derived from image correspondences and robot kinematic measurements to estimate camera poses. The performance of the method is evaluated in environments without engineered calibration targets or overlapping fields of view between camera pairs.","abstract_html":"Cameras are a common and cost-effective sensing modality for robotic platforms, enabling systems to collect visual information about their operating environment and support downstream perception tasks. In particular, the pose of each camera relative to the robot frame must be defined with respect to a known reference through a process known as extrinsic calibration. Each new sensor added to a robotic system must be incorporated into the calibrated configuration, which increases the calibration effort for both new and existing robotic systems. Over the operational lifespan of a robotic system, mechanical shock, structural drift, or maintenance activities may alter the physical configuration of mounted cameras, compromising previously estimated extrinsic parameters and necessitating recalibration. Camera calibration typically requires moving the robotic platform through a range of poses to collect imagery of the surrounding environment. Establishing correspondences between two-dimensional image observations and three-dimensional scene structure generally requires knowledge of a baseline that enables depth estimation. Such information may be obtained through engineered calibration targets, sensor fusion with depth-measuring instruments, or stereo camera configurations with known baselines. In this work, we present the design and implementation of a procedure for calibrating the extrinsic parameters of multiple cameras mounted on a robotic platform without requiring explicit depth measurements. The proposed approach leverages pairwise two-view geometry derived from image correspondences and robot kinematic measurements to estimate camera poses. The performance of the method is evaluated in environments without engineered calibration targets or overlapping fields of view between camera pairs.","abstract_has_math":false,"creators":["Singh, Kiran"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Software Engineering","school":null,"contributors":[],"advisors":["Giamou, Matthew"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:34:05Z","subjects":[],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/15721"],"render_values":[{"text":"https://doi.org/10.71548/15721","href":"https://doi.org/10.71548/15721","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11375/33133","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11375/33133","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F33133","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giamou, Matthew"]},{"key":"dc:contributor.department","label":"Department","values":["Software Engineering"]},{"key":"dc:creator","label":"Author","values":["Singh, Kiran"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-12T18:29:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11375/33133","https://doi.org/10.71548/15721"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Cameras are a common and cost-effective sensing modality for robotic platforms, enabling systems to collect visual information about their operating environment and support downstream perception tasks. In particular, the pose of each camera relative to the robot frame must be defined with respect to a known reference through a process known as extrinsic calibration. Each new sensor added to a robotic system must be incorporated into the calibrated configuration, which increases the calibration effort for both new and existing robotic systems. Over the operational lifespan of a robotic system, mechanical shock, structural drift, or maintenance activities may alter the physical configuration of mounted cameras, compromising previously estimated extrinsic parameters and necessitating recalibration. Camera calibration typically requires moving the robotic platform through a range of poses to collect imagery of the surrounding environment. Establishing correspondences between two-dimensional image observations and three-dimensional scene structure generally requires knowledge of a baseline that enables depth estimation. Such information may be obtained through engineered calibration targets, sensor fusion with depth-measuring instruments, or stereo camera configurations with known baselines. In this work, we present the design and implementation of a procedure for calibrating the extrinsic parameters of multiple cameras mounted on a robotic platform without requiring explicit depth measurements. The proposed approach leverages pairwise two-view geometry derived from image correspondences and robot kinematic measurements to estimate camera poses. The performance of the method is evaluated in environments without engineered calibration targets or overlapping fields of view between camera pairs."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["Hand-Eye Calibration of Multiple Monocular Cameras"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Multi-Camera Extrinsic Calibration"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giamou, Matthew"],"dc:contributor.department":["Software Engineering"],"dc:creator":["Singh, Kiran"],"dc:date.accessioned":["2026-05-12T18:29:49Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Cameras are a common and cost-effective sensing modality for robotic platforms, enabling systems to collect visual information about their operating environment and support downstream perception tasks. In particular, the pose of each camera relative to the robot frame must be defined with respect to a known reference through a process known as extrinsic calibration. Each new sensor added to a robotic system must be incorporated into the calibrated configuration, which increases the calibration effort for both new and existing robotic systems. Over the operational lifespan of a robotic system, mechanical shock, structural drift, or maintenance activities may alter the physical configuration of mounted cameras, compromising previously estimated extrinsic parameters and necessitating recalibration. Camera calibration typically requires moving the robotic platform through a range of poses to collect imagery of the surrounding environment. Establishing correspondences between two-dimensional image observations and three-dimensional scene structure generally requires knowledge of a baseline that enables depth estimation. Such information may be obtained through engineered calibration targets, sensor fusion with depth-measuring instruments, or stereo camera configurations with known baselines. In this work, we present the design and implementation of a procedure for calibrating the extrinsic parameters of multiple cameras mounted on a robotic platform without requiring explicit depth measurements. The proposed approach leverages pairwise two-view geometry derived from image correspondences and robot kinematic measurements to estimate camera poses. The performance of the method is evaluated in environments without engineered calibration targets or overlapping fields of view between camera pairs."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.uri":["https://hdl.handle.net/11375/33133","https://doi.org/10.71548/15721"],"dc:language.iso":["en"],"dc:title":["Hand-Eye Calibration of Multiple Monocular Cameras"],"dc:title.alternative":["Multi-Camera Extrinsic Calibration"],"dc:type":["Thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:34:05Z"}