{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/33852"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/33852","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Smart Magnetically Actuated RoboT Fabrication","abstract":"Microrobots have gained heightened interest in recent years for their unique properties and advanced potential. Their applications vary across environmental monitoring, manufacturing, and biotechnology, with a major focus in the healthcare industry. Currently, robotic systems have been used in medical practice for wound patching, removing foreign bodies, delivering drugs, and performing biopsies. Research has been pushing the limits of robotics to expand navigation, treatment, and diagnosis by reducing the scale of devices using magnetic actuation. Magnetic microrobots have been extensively studied for their ability to crawl, grab, and swim. However, these complex and controllable deformations require discrete magnetization patterns to be programmed throughout device fabrication. Currently, microrobots are often micro-assembled with pre-programmed magnetized blocks or post-magnetized in the desired deformation state. Both approaches suffer from limited reproducibility, leading to variation in performance between devices. An automated method of fabricating selectively programmed magnetic domains throughout a complex geometric device is vital for success in industrial use. This work optimizes the resolution of a stereolithography-based printer created for the development of magnetic microrobots. Through the design, modelling, and experimental validation of three optical configurations, the resolution was refined from circles of 1.6 mm in diameter to squares 90 μm across, with functional devices showing magnetized segments at 200 μm. A magnetomechanical simulation platform was then developed in COMSOL Multiphysics to optimize magnetic domain placement and evaluate design behaviours under applied magnetic fields. Subsequently, fabrication was extended into the pre-programming of magnetic domains within multimaterial structures, integrating various physical and chemical properties. A digital light processing-based printer was designed with up to six materials and custom software was created and validated for the slicing of computer-modelled devices into printing instructions. These contributions establish a foundation towards rapid, reproducible fabrication of increasingly complex magnetic microrobots with a variety of integrated materials.","abstract_html":"Microrobots have gained heightened interest in recent years for their unique properties and advanced potential. Their applications vary across environmental monitoring, manufacturing, and biotechnology, with a major focus in the healthcare industry. Currently, robotic systems have been used in medical practice for wound patching, removing foreign bodies, delivering drugs, and performing biopsies. Research has been pushing the limits of robotics to expand navigation, treatment, and diagnosis by reducing the scale of devices using magnetic actuation. Magnetic microrobots have been extensively studied for their ability to crawl, grab, and swim. However, these complex and controllable deformations require discrete magnetization patterns to be programmed throughout device fabrication. Currently, microrobots are often micro-assembled with pre-programmed magnetized blocks or post-magnetized in the desired deformation state. Both approaches suffer from limited reproducibility, leading to variation in performance between devices. An automated method of fabricating selectively programmed magnetic domains throughout a complex geometric device is vital for success in industrial use. This work optimizes the resolution of a stereolithography-based printer created for the development of magnetic microrobots. Through the design, modelling, and experimental validation of three optical configurations, the resolution was refined from circles of 1.6 mm in diameter to squares 90 μm across, with functional devices showing magnetized segments at 200 μm. A magnetomechanical simulation platform was then developed in COMSOL Multiphysics to optimize magnetic domain placement and evaluate design behaviours under applied magnetic fields. Subsequently, fabrication was extended into the pre-programming of magnetic domains within multimaterial structures, integrating various physical and chemical properties. A digital light processing-based printer was designed with up to six materials and custom software was created and validated for the slicing of computer-modelled devices into printing instructions. These contributions establish a foundation towards rapid, reproducible fabrication of increasingly complex magnetic microrobots with a variety of integrated materials.","abstract_has_math":false,"creators":["Clancy, Kaitlyn"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Onaizah, Onaizah"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:36:23Z","subjects":["Magnetic Microrobots","Fabrication","Photopolymerization","Medical Microrobots"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/25622"],"render_values":[{"text":"https://doi.org/10.71548/25622","href":"https://doi.org/10.71548/25622","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11375/33852","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11375/33852","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F33852","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Onaizah, Onaizah"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Clancy, Kaitlyn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-15T12:11:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Magnetic Microrobots","Fabrication","Photopolymerization","Medical Microrobots"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivs 2.5 Canada"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11375/33852","https://doi.org/10.71548/25622"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Microrobots have gained heightened interest in recent years for their unique properties and advanced potential. Their applications vary across environmental monitoring, manufacturing, and biotechnology, with a major focus in the healthcare industry. Currently, robotic systems have been used in medical practice for wound patching, removing foreign bodies, delivering drugs, and performing biopsies. Research has been pushing the limits of robotics to expand navigation, treatment, and diagnosis by reducing the scale of devices using magnetic actuation. Magnetic microrobots have been extensively studied for their ability to crawl, grab, and swim. However, these complex and controllable deformations require discrete magnetization patterns to be programmed throughout device fabrication. Currently, microrobots are often micro-assembled with pre-programmed magnetized blocks or post-magnetized in the desired deformation state. Both approaches suffer from limited reproducibility, leading to variation in performance between devices. An automated method of fabricating selectively programmed magnetic domains throughout a complex geometric device is vital for success in industrial use. This work optimizes the resolution of a stereolithography-based printer created for the development of magnetic microrobots. Through the design, modelling, and experimental validation of three optical configurations, the resolution was refined from circles of 1.6 mm in diameter to squares 90 μm across, with functional devices showing magnetized segments at 200 μm. A magnetomechanical simulation platform was then developed in COMSOL Multiphysics to optimize magnetic domain placement and evaluate design behaviours under applied magnetic fields. Subsequently, fabrication was extended into the pre-programming of magnetic domains within multimaterial structures, integrating various physical and chemical properties. A digital light processing-based printer was designed with up to six materials and custom software was created and validated for the slicing of computer-modelled devices into printing instructions. These contributions establish a foundation towards rapid, reproducible fabrication of increasingly complex magnetic microrobots with a variety of integrated materials."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["This research was supported by the Natural Sciences and Engineering Council of Canada (NSERC) through the Discovery Grant RGPIN-2024-06700, and the Canada Foundation for Innovation–John R. Evans Leaders Fund (grant no. 44508)."]},{"key":"dc:title","label":"Title","values":["Smart Magnetically Actuated RoboT Fabrication"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["SMART Fabrication"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Onaizah, Onaizah"],"dc:contributor.department":["Biomedical Engineering"],"dc:creator":["Clancy, Kaitlyn"],"dc:date.accessioned":["2026-10-15T12:11:27Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Microrobots have gained heightened interest in recent years for their unique properties and advanced potential. Their applications vary across environmental monitoring, manufacturing, and biotechnology, with a major focus in the healthcare industry. Currently, robotic systems have been used in medical practice for wound patching, removing foreign bodies, delivering drugs, and performing biopsies. Research has been pushing the limits of robotics to expand navigation, treatment, and diagnosis by reducing the scale of devices using magnetic actuation. Magnetic microrobots have been extensively studied for their ability to crawl, grab, and swim. However, these complex and controllable deformations require discrete magnetization patterns to be programmed throughout device fabrication. Currently, microrobots are often micro-assembled with pre-programmed magnetized blocks or post-magnetized in the desired deformation state. Both approaches suffer from limited reproducibility, leading to variation in performance between devices. An automated method of fabricating selectively programmed magnetic domains throughout a complex geometric device is vital for success in industrial use. This work optimizes the resolution of a stereolithography-based printer created for the development of magnetic microrobots. Through the design, modelling, and experimental validation of three optical configurations, the resolution was refined from circles of 1.6 mm in diameter to squares 90 μm across, with functional devices showing magnetized segments at 200 μm. A magnetomechanical simulation platform was then developed in COMSOL Multiphysics to optimize magnetic domain placement and evaluate design behaviours under applied magnetic fields. Subsequently, fabrication was extended into the pre-programming of magnetic domains within multimaterial structures, integrating various physical and chemical properties. A digital light processing-based printer was designed with up to six materials and custom software was created and validated for the slicing of computer-modelled devices into printing instructions. These contributions establish a foundation towards rapid, reproducible fabrication of increasingly complex magnetic microrobots with a variety of integrated materials."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:description.sponsorship":["This research was supported by the Natural Sciences and Engineering Council of Canada (NSERC) through the Discovery Grant RGPIN-2024-06700, and the Canada Foundation for Innovation–John R. Evans Leaders Fund (grant no. 44508)."],"dc:identifier.uri":["https://hdl.handle.net/11375/33852","https://doi.org/10.71548/25622"],"dc:language.iso":["en"],"dc:rights":["Attribution-NonCommercial-NoDerivs 2.5 Canada"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/2.5/ca/"],"dc:subject":["Magnetic Microrobots","Fabrication","Photopolymerization","Medical Microrobots"],"dc:title":["Smart Magnetically Actuated RoboT Fabrication"],"dc:title.alternative":["SMART Fabrication"],"dc:type":["Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-18T19:36:23Z"}