{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/33853"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/33853","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Soft Magnetically Actuated Robotic Tools for Ear, Nose, and Throat Surgery","abstract":"Robotic surgical assistance systems have gained wide attention within the past 25 years due to enhanced precision and reproducibility over manual intervention, thus improving patient outcomes and recovery time. However, many of the leading systems that afford these advantages still employ rigid end effectors that impede the angles of approach and dexterity necessary in many procedures. Other commercialized solutions are emerging that deploy more flexible tools, but maintain the cost and rigid outer body associated with these previous devices, imposing greater risks of trauma and adverse effects as modelling and control become more challenging. Therefore, the specialized nature of surgical care and high capital cost associated with these systems significantly limit their wide adaptability and accessibility for healthcare institutions globally. This thesis work aims to address this clinical gap with the development of functionalized magnetic soft continuum robots for sinus surgery with improved access, reach, and therefore patient recovery. Demonstrating the iterative expansion of compatible tools for magnetic soft continuum robots, including an active channel for drug delivery or suction, LED for illumination and laser fibre simulation, endoscopic camera, and snare end effector. All of which are supported by a reproducible and rapid fabrication process, as well as a modular and cost-effective actuation system to operate them. Characterization testing was done to inform the development process, including future design directions and improving control of the continuum robots. Extended to more practical and realistic functional testing within mazes and nasal phantoms, substantiating tool capabilities and potential for clinical translation. Ultimately, demonstrating the vast promise that magnetic soft continuum robots can offer for efforts to advance the standard of sinus surgery care and robotic-assisted interventions in general.","abstract_html":"Robotic surgical assistance systems have gained wide attention within the past 25 years due to enhanced precision and reproducibility over manual intervention, thus improving patient outcomes and recovery time. However, many of the leading systems that afford these advantages still employ rigid end effectors that impede the angles of approach and dexterity necessary in many procedures. Other commercialized solutions are emerging that deploy more flexible tools, but maintain the cost and rigid outer body associated with these previous devices, imposing greater risks of trauma and adverse effects as modelling and control become more challenging. Therefore, the specialized nature of surgical care and high capital cost associated with these systems significantly limit their wide adaptability and accessibility for healthcare institutions globally. This thesis work aims to address this clinical gap with the development of functionalized magnetic soft continuum robots for sinus surgery with improved access, reach, and therefore patient recovery. Demonstrating the iterative expansion of compatible tools for magnetic soft continuum robots, including an active channel for drug delivery or suction, LED for illumination and laser fibre simulation, endoscopic camera, and snare end effector. All of which are supported by a reproducible and rapid fabrication process, as well as a modular and cost-effective actuation system to operate them. Characterization testing was done to inform the development process, including future design directions and improving control of the continuum robots. Extended to more practical and realistic functional testing within mazes and nasal phantoms, substantiating tool capabilities and potential for clinical translation. Ultimately, demonstrating the vast promise that magnetic soft continuum robots can offer for efforts to advance the standard of sinus surgery care and robotic-assisted interventions in general.","abstract_has_math":false,"creators":["Smith, Griffin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Biomedical Engineering","school":null,"contributors":[],"advisors":["Onaizah, Onaizah"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:38:03Z","subjects":["Continuum Robots","Magnetics","Surgery","Soft Surgical Robotics"],"languages":["en"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/25623"],"render_values":[{"text":"https://doi.org/10.71548/25623","href":"https://doi.org/10.71548/25623","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11375/33853","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11375/33853","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F33853","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Onaizah, Onaizah"]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Smith, Griffin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-15T12:18:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Continuum Robots","Magnetics","Surgery","Soft Surgical Robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/11375/33853","https://doi.org/10.71548/25623"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Robotic surgical assistance systems have gained wide attention within the past 25 years due to enhanced precision and reproducibility over manual intervention, thus improving patient outcomes and recovery time. However, many of the leading systems that afford these advantages still employ rigid end effectors that impede the angles of approach and dexterity necessary in many procedures. Other commercialized solutions are emerging that deploy more flexible tools, but maintain the cost and rigid outer body associated with these previous devices, imposing greater risks of trauma and adverse effects as modelling and control become more challenging. Therefore, the specialized nature of surgical care and high capital cost associated with these systems significantly limit their wide adaptability and accessibility for healthcare institutions globally. This thesis work aims to address this clinical gap with the development of functionalized magnetic soft continuum robots for sinus surgery with improved access, reach, and therefore patient recovery. Demonstrating the iterative expansion of compatible tools for magnetic soft continuum robots, including an active channel for drug delivery or suction, LED for illumination and laser fibre simulation, endoscopic camera, and snare end effector. All of which are supported by a reproducible and rapid fabrication process, as well as a modular and cost-effective actuation system to operate them. Characterization testing was done to inform the development process, including future design directions and improving control of the continuum robots. Extended to more practical and realistic functional testing within mazes and nasal phantoms, substantiating tool capabilities and potential for clinical translation. Ultimately, demonstrating the vast promise that magnetic soft continuum robots can offer for efforts to advance the standard of sinus surgery care and robotic-assisted interventions in general."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["This work is supported by the Natural Sciences and Engineering Research Council of Canada (NSERC) through their Discovery Grant RGPIN-2024-06700, Canada Foundation for Innovation-John R. Evans Leaders Fund through grant 44508 and the McMaster Entrepreneurship Academy."]},{"key":"dc:title","label":"Title","values":["Soft Magnetically Actuated Robotic Tools for Ear, Nose, and Throat Surgery"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["SMART-ENT"]},{"key":"others:access_status","label":"Others Access Status","values":["embargo"]}]}],"canonical_facts":{"dc:contributor.advisor":["Onaizah, Onaizah"],"dc:contributor.department":["Biomedical Engineering"],"dc:creator":["Smith, Griffin"],"dc:date.accessioned":["2026-10-15T12:18:17Z"],"dc:date.issued":["2026"],"dc:description.abstract":["Robotic surgical assistance systems have gained wide attention within the past 25 years due to enhanced precision and reproducibility over manual intervention, thus improving patient outcomes and recovery time. However, many of the leading systems that afford these advantages still employ rigid end effectors that impede the angles of approach and dexterity necessary in many procedures. Other commercialized solutions are emerging that deploy more flexible tools, but maintain the cost and rigid outer body associated with these previous devices, imposing greater risks of trauma and adverse effects as modelling and control become more challenging. Therefore, the specialized nature of surgical care and high capital cost associated with these systems significantly limit their wide adaptability and accessibility for healthcare institutions globally. This thesis work aims to address this clinical gap with the development of functionalized magnetic soft continuum robots for sinus surgery with improved access, reach, and therefore patient recovery. Demonstrating the iterative expansion of compatible tools for magnetic soft continuum robots, including an active channel for drug delivery or suction, LED for illumination and laser fibre simulation, endoscopic camera, and snare end effector. All of which are supported by a reproducible and rapid fabrication process, as well as a modular and cost-effective actuation system to operate them. Characterization testing was done to inform the development process, including future design directions and improving control of the continuum robots. Extended to more practical and realistic functional testing within mazes and nasal phantoms, substantiating tool capabilities and potential for clinical translation. Ultimately, demonstrating the vast promise that magnetic soft continuum robots can offer for efforts to advance the standard of sinus surgery care and robotic-assisted interventions in general."],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:description.sponsorship":["This work is supported by the Natural Sciences and Engineering Research Council of Canada (NSERC) through their Discovery Grant RGPIN-2024-06700, Canada Foundation for Innovation-John R. Evans Leaders Fund through grant 44508 and the McMaster Entrepreneurship Academy."],"dc:identifier.uri":["https://hdl.handle.net/11375/33853","https://doi.org/10.71548/25623"],"dc:language.iso":["en"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:subject":["Continuum Robots","Magnetics","Surgery","Soft Surgical Robotics"],"dc:title":["Soft Magnetically Actuated Robotic Tools for Ear, Nose, and Throat Surgery"],"dc:title.alternative":["SMART-ENT"],"dc:type":["Thesis"],"others:access_status":["embargo"]},"updated_at":"2026-11-18T19:38:03Z"}