{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/6023"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/6023","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Human Locomotion: Techniques for Processing and Analysis of EMG Data","abstract":"<p>Several techniques used by researchers in the area of human locomotion to process and analyse normal and pathological gait electromyographs (EMG) are discussed. Basic elements of neuromuscular organization are described.</p> <p>The thesis reports original work in several topic. The spectral analysis of dynamic EMG acquired during the locomotion of a normal subject was done to confirm the selected sampling frequency, and to determine a suitable low pass filter cutoff for smoothing EMG prior to data analysis.</p> <p>Results of using two filters for smoothing EMG, a second order Butterworth low pass filter, and a mid-point moving window average filter are compared.</p> <p>The cross correlation function is used in analysing EMG, since EMG signals are random. The results of cross correlation are compared with clinical observations in assessing the state of a patient following a stroke. Results for five normal and fourteen hemiplegic subjects are reported.</p> <p>The conclusion is that cross correlation analysis quantifies the state of the patient and assesses post stroke recovery according to the neurological picture of central nervous system control.</p>","abstract_html":"&lt;p&gt;Several techniques used by researchers in the area of human locomotion to process and analyse normal and pathological gait electromyographs (EMG) are discussed. Basic elements of neuromuscular organization are described.&lt;/p&gt; &lt;p&gt;The thesis reports original work in several topic. The spectral analysis of dynamic EMG acquired during the locomotion of a normal subject was done to confirm the selected sampling frequency, and to determine a suitable low pass filter cutoff for smoothing EMG prior to data analysis.&lt;/p&gt; &lt;p&gt;Results of using two filters for smoothing EMG, a second order Butterworth low pass filter, and a mid-point moving window average filter are compared.&lt;/p&gt; &lt;p&gt;The cross correlation function is used in analysing EMG, since EMG signals are random. The results of cross correlation are compared with clinical observations in assessing the state of a patient following a stroke. Results for five normal and fourteen hemiplegic subjects are reported.&lt;/p&gt; &lt;p&gt;The conclusion is that cross correlation analysis quantifies the state of the patient and assesses post stroke recovery according to the neurological picture of central nervous system control.&lt;/p&gt;","abstract_has_math":false,"creators":["Marsh, Amanda Eva Mary"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Bruin, H. de","Kitai, R."],"committee_chairs":[],"committee_members":[],"year":1981,"date_issued":"1981-09","date_published":"1981-09","updated_at":"2026-11-18T19:38:49Z","subjects":["Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/22084"],"render_values":[{"text":"https://doi.org/10.71548/22084","href":"https://doi.org/10.71548/22084","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/136","1478","913080"],"render_values":[{"text":"opendissertations/136","href":null,"code":true},{"text":"1478","href":null,"code":true},{"text":"913080","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/6023","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/6023","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F6023","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bruin, H. de","Kitai, R."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Marsh, Amanda Eva Mary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:33:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:33:55Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-07-28"]},{"key":"dc:date.issued","label":"Date","values":["1981-09"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/136","1478","913080"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/6023","https://doi.org/10.71548/22084"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Several techniques used by researchers in the area of human locomotion to process and analyse normal and pathological gait electromyographs (EMG) are discussed. Basic elements of neuromuscular organization are described.</p> <p>The thesis reports original work in several topic. The spectral analysis of dynamic EMG acquired during the locomotion of a normal subject was done to confirm the selected sampling frequency, and to determine a suitable low pass filter cutoff for smoothing EMG prior to data analysis.</p> <p>Results of using two filters for smoothing EMG, a second order Butterworth low pass filter, and a mid-point moving window average filter are compared.</p> <p>The cross correlation function is used in analysing EMG, since EMG signals are random. The results of cross correlation are compared with clinical observations in assessing the state of a patient following a stroke. Results for five normal and fourteen hemiplegic subjects are reported.</p> <p>The conclusion is that cross correlation analysis quantifies the state of the patient and assesses post stroke recovery according to the neurological picture of central nervous system control.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["Human Locomotion: Techniques for Processing and Analysis of EMG Data"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bruin, H. de","Kitai, R."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Marsh, Amanda Eva Mary"],"dc:date.accessioned":["2014-06-18T16:33:55Z"],"dc:date.available":["2014-06-18T16:33:55Z"],"dc:date.created":["2009-07-28"],"dc:date.issued":["1981-09"],"dc:description.abstract":["<p>Several techniques used by researchers in the area of human locomotion to process and analyse normal and pathological gait electromyographs (EMG) are discussed. Basic elements of neuromuscular organization are described.</p> <p>The thesis reports original work in several topic. The spectral analysis of dynamic EMG acquired during the locomotion of a normal subject was done to confirm the selected sampling frequency, and to determine a suitable low pass filter cutoff for smoothing EMG prior to data analysis.</p> <p>Results of using two filters for smoothing EMG, a second order Butterworth low pass filter, and a mid-point moving window average filter are compared.</p> <p>The cross correlation function is used in analysing EMG, since EMG signals are random. The results of cross correlation are compared with clinical observations in assessing the state of a patient following a stroke. Results for five normal and fourteen hemiplegic subjects are reported.</p> <p>The conclusion is that cross correlation analysis quantifies the state of the patient and assesses post stroke recovery according to the neurological picture of central nervous system control.</p>"],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.other":["opendissertations/136","1478","913080"],"dc:identifier.uri":["http://hdl.handle.net/11375/6023","https://doi.org/10.71548/22084"],"dc:subject":["Electrical and Electronics"],"dc:title":["Human Locomotion: Techniques for Processing and Analysis of EMG Data"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:49Z"}